Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC 07 SUKHATOLA DUMARI KASIA KUSHINAGAR UTTAR PRADESH 274402 | KUSHI NAGAR | UTTAR PRADESH | 274402 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹3.8 L+₹44,262.95 (13.3%)Rejected-Finance | L2 | Rejected-Finance L2 BIDDER | |
| 3 | L3₹3.9 L+₹57,828 (17.4%)Rejected-Finance | L3 | Rejected-Finance L3 BIDDER | |
| 4 | L4₹4.6 L+₹1.3 L (40.0%)Rejected-Finance | L4 | Rejected-Finance L4 BIDDER | |
| 5 | L5₹5.2 L+₹1.9 L (57.5%)Rejected-Finance | L5 | Rejected-Finance L5 BIDDER |
Tender Value
₹3.8 L
EMD Value
₹7,500
Closing Date
3 May 2021, 3:00 pmClosed
Administrative Officer
CSIR-Indian Institute of Chemical Biology, 4 Raja S.C. Mullick Road, Jadavpur, Kolkata 700032.
Annual Maintenance Contract of Electrical installations.
2021_CSIR_74707_1
CSIR_IICB / Admn 26(653) / E / 2021
Open Tender
Electrical Works
Item Rate
365 days
CSIR IICB Salt Lake Campus.
Executed Electrical installation Works in Government or Semi Government Organizations / CSIR / CSIR Laboratories in anywhere in India.
4 documents required · 4 mandatory
₹0
₹7,500
30 Nov 2021
20 Apr 2021
4 May 2021
20 Apr 2021
3 May 2021
21 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
3 x 10 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC Casing Caping along with accessories in surface/recess including all accessories.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 X 10 sq. mm (22mm)
3 X 16 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
4 X 35 sq. mm (32mm)
4 X 50 sq. mm (35mm)
4 X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
6 Module
12 Module
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100 mm X 100 mm X 60 mm deep
200 mm X 150 mm X 60 mm deep
200 mm X 250 mm X 60 mm deep
Supplying and fixing 16 swg metal box of 200 mm x 250 mm x 60 mm sizes (nominal size) on surface or in recess with suitable size of 3 mm thick phenolic laminated sheet cover in front including switch & sockets 1x20A + 2x6A + 1x16A fuse + 1x16A plug top+ Indication lamp + 5 meter 2.5 sq mm round PVC cord (Copper wire) as required all complete.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply of following Electrical items.
40A, 2 Pole RCCB, 300mA, (Hager cat. Reference. Y5254)
40A, 4 Pole RCCB, 300mA, (Hager cat. Reference. Y5454)
63A, 4 Pole RCCB, 300mA, (Hager cat. Reference. Y5456)
40A, 4 module MCB, (Hager cat. Reference. Y1440)
63A, 4 module MCB, (Hager cat. Reference.Y1463)
300 mm Sweep, 90 Watt, 1400 RPM Exhaust Fan
PL-C, 2P 18 Watt/86 Lamp, Philips or equivalent.
Open Ballast for PL-C 18 Watt/86 Lamp, Philips or equivalent.
PL-L 4P 36 Watt/865 Lamp, Philips or equivalent.
Electronic Ballast for 3 X PL-L 36 Watt lamp, Make- Philips EBP 336 or equivalent.
Electronic Ballast for 2 X PL-L 36 Watt lamp, Make- Philips EBP 236 or equivalent.
Supply of 14 Watt Pin Type LED Bulb. Make Philips or equivalent.
B22 Screw Base Socket Ceramic Lamp Holder
T5 28 Watt 6500K Tube Light. Make Philips (TL-5, 28W/865) or equivalent.
36 Watt, 6500K Fluorescent Tube Light. Philips (TL-D 36W/54) or equivalent.
18 Watt, 6500K Fluorescent Tube Light. Philips (TL-D 18W/54) or equivalent.
Door Bells, 240 Volt AC, Anchor or equivalent.
6A, 3 Pin Plug Top
16A 3 Pin Plug Top
2.5 mfd capacitor for ceiling fan
Self Adhesive PVC Electrical insulation tape, approximate Size (1.80cm X 6.5m X 0.125 mm). Make - Steelgrip or equivalent.
Analog Street Light Time Switch (Make L&T or equivalent.)
On Delay Timer, TC TA2DT4 (0-180S), Make- C&S Electric.
16-25A Screw Type Single Phase Motor Starter.
80A, Icu- 25kA, Four Pole MCCB, Overload adjustable, Make Hager HHA081U or equivalent.
22.5mm,240V AC LED Indication Lamp (Red)
22.5mm,240V AC LED Indication Lamp (Yellow)
22.5mm,240V AC LED Indication Lamp (Blue)
22.5mm,240V AC LED Indication Lamp (Green)
22.5mm,240V AC LED Indication Lamp (Amber)
Electrical Panel Lock (Mild Steel), Size- 22.5mm approx.
Supply and Installation of LED Flood Light with following features: 1.Operating Voltage and Frequency: 140V-270 V AC, 50Hz. 2.Wattage : 120 - 130 W 3.Efficacy : 95 -105 Lm / W 4.Colour : 5400K-6000K 5.Power Factor: > 95% 6.Protection: IP 66 7.Replacement Warranty : More than ≥ 2 Years 8.Make: Bajaj / Crompton Greaves / Philips /Syska/ Jaquar.
Supply and Installation of LED Mirror Light Fitting with following features: 1. Maximum Wattage replacement of Bulb - 12 Watt 2. Voltage Range- 220 - 240 Volt AC. 3. Light Direction- Down Ward 4. Material- Metal & Glass 5. Shade Colour & Material- White & Opal Glass. 6.Replacement Warranty : More than ≥ 1 Year. 7.Make: Philips /Syska/ Jaquar/Bajaj / Crompton Greaves.
Supply and replacement of movement detectors with following features. 1. Inbuilt ambient light sensors with adjustable lux level 5 to 1000 lux. 2. Adjustable time delay up to 15 minutes. 3.Single lens 360°, 1 channel, 10A, 1 NO contact. 4.Detection Range 6 metre dia, surface mounted). 3.Make: Hager EE804A or Equivalent.
Supply and replacement of Surface Mounted (round) Decorative LED luminaire with following specification. 1. 15-18 Watt 2. Colour- Cool White 3. Input Voltage - 240 Volt AC 4. Make- Bajaj / Crompton Greaves / Philips /Syska/ Jaquar.
Supply, Installation, testing & Commissioning of 400 mm sweep, 230 Volt, 55-60 watt 1280-1320 RPM oscillating type wall mounting fan with built in regulator connection, testing and commissioning etc. as required.
Supply, Installation, testing & Commissioning of Circular Duct Fan with existing air ventilation duct. The job includes all commissioning materials and accessories. The fan Comprising of following Specifications. 1. Power- 190 W (Approx.) 2. Speed - 2465 RPM (Approx.) 3. Voltage- 230 Volt AC. 4. Current- 0.84 A (Approx.) 5. Frequency- 50 Hz. 4.Insulation Class of Motor- F Make Ostberg CK315 B or its equivalent.
Supply, Installation, Testing and Commissioning of Automatic 2 AC Controller with provision of Time, Voltage and Current adjustment and protection facility (Parameters are to be user adjustable) complete as required. (Ultrasafe UTCON 07C or its equivalent make and model.) Installation part is including all accessories like Lugs, Screw, Bolts etc.
Supply, Installation and Testing of IO box Suitable for LAN Connection incuding supply and fixing of connectors etc. Complete as required.
Rewinding, overhauling, painting of ceiling fan upto 56" with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, scraping of old paint, cleaning of surface with detergent etc. including connection, etc all complete as required.
Rewinding and overhauling of exhaust fans upto 18" sweep including disconnecting and reinstallation of the same complete as required.
Installation, testing and commissioning of ceiling fan including accessories like Hanger, Fastner, down rod upto 1.5 m etc. as required.
Installation of exhaust fan of size 300 mm sweep including making the hole to suit the size of the above fan, making good the damages, testing commissioning, etc. all complete as required.
Painting and numbering of Sodium Vapour Street Light Poles (Appx.ht 30 ft.) including following jobs. 1. Scraping and Cleaning of worn out painting from light poles. 2.Painting with 1 coat of Red Oxide Primer and then 2 coats of Aluminium Paints(Make-Asian Paints/Berger). 3. Numbering of street Poles with paints.
Painting and numbering of Decorative Street Light Poles (Appx.ht 12 ft.) including following jobs. 1. Scraping and Cleaning of worn out painting from light poles. 2.Painting with 1 coat of Red Oxide Primer and then 2 coats of Aluminium Paints(Make-Asian Paints/Berger). 3. Numbering of street Poles with paints.
Servicing, repairing and upkeeping of Electrical Junction Box of Street Light/Flood Light pole. The job includes Replacement of Cable Connectors and Cable lugs,Cleaning and Painting of every Junction Box etc.
Servicing, Maintenance & upkeeping of every Electrical Panels and Distribution boards installed at CSIR-IICB Salt Lake Campus comprising of following jobs. 1. Cleaning and Upkeeping of every Electrical Panels and D.B.s installed at CSIR-IICB Salt Lake Campus. (For specification and Quantity of Eelctrical panels and DBs please see Brief Particular of Work at Tender Document.) 2. Checking, Tightening of Electrical wirings, and other components, Checking and Fault Tracing of Electrical interlocks inside Panels etc. 3. Replacement of faulty components and accessories (like MCBs, Relays, Contactors, Timers, wires, Indication lamps etc.) installed at Electrical Panels and DBs.(Electrical Components and accessories will be supplied departmentally.)
Engaging of Highly Skilled/ semi skilled /UnSkilled man power (including holidays) for execution of Electrical works and as per the direction of Engineer-in-charge of the work:
Skilled
Un Skilled/ Helper
The Suburban Electric Co.
scientific refregeration
International C0mmercial Corporation
Imperial Solar Solutions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .