Tender Value
₹46.5 L
EMD Value
₹93,100
Closing Date
11 Nov 2021, 6:00 pmClosed
Garrison Engineer
GE I DM REPAIR, REPLACEMENT OF DAMAGED HT 11 KV UNDERGROUND CABLES OF VARIOUS SIZES OF 11 KV RING MAIN CONNECTIONS AND ALLIED WORKS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM 530014
REPAIR, REPLACEMENT OF DAMAGED HT 11 KV UNDERGROUND CABLES OF VARIOUS SIZES OF 11 KV RING MAIN CONNECTIONS AND ALLIED WORKS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2021_MES_483065_1
SSGE/8642/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAVAL DOCKYARD VISAKHAPATNAM
As per tender documents
9 documents required · 9 mandatory
₹500
GE I DM
₹93,100
Yes
17 Dec 2021
21 Oct 2021
18 Nov 2021
21 Oct 2021
11 Nov 2021
4 Nov 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed
M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed
M&L for PCC 1:3:6 , type-C 2, using 40mm graded agregrate for repair to path/drain/road against damage due to excavation /laying of cable complete all as specified and as directed
Dismantling taking out HT/LT Cable from cable duct of substations for realingnment of cable and relaying with proper alingnment including necessory required clamping for the cable and connecting up of size 3/3.5 core, 185 sqmm, 11000/1100 volts grade. (Note: Each cable shall be measured separately. Steel cable rack shall be measured separately as supply and fix) complete all as specified and as directed
All as per item No 7.00 above but for cable sizes 185sqmm
All as per item No 7.00 above but for cable sizes 240sqmm
All as per item No 7.00 above but for cable sizes 300sqmm
All as per item No 7.00 above but for cable sizes 400sqmm
Supply & laying in trenches or in duct or passing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (Earthed) cross sectional area 185 sq. mm 3 core including dismantling / taking down unserviceable one complete all as specified and as directed
All as per item No 12.00 above but of size 240 sq. mm 3 core including dismantling / taking down unserviceable one
All as per item No 12.00 above but of size 300 sq. mm 3 core including dismantling / taking down unserviceable one
All as per item No 12.00 above but of size 400 sq. mm 3 core including dismantling / taking down unserviceable one
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm after opening VCB panel back side cable cover and bottom cable entry plate after disconneting unsv cable kit from busbar/CT, taking out from VCB cable chamber and fixing the same to original position, with new or old nuts, bolts & washers, bottom plate, back cover and making cable entry point totally sealed with putty complete all as specified and as directed.
All as per item No 16.00 above but (indoor termination) for cable of size 240sqmm to 300 sqmm including dismantling / taking down unserviceable one.
All as per item No 16.00 above but (indoor termination) for cable of size 400 sqmm incl dismantling / taking down unserviceable one.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for out-door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmmafter after disconneting unsv cable kit from busbar at strcture, taking out carefully after opening clamp at structure to GL and fixing the same to original position, with new or old nuts, bolts & washers, clamp at structure complete all as specified and as directed.
S&F Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm including dismantling / taking down unserviceable one complete all as specified and as directed .
All as per item No 20.00 above but (straight through heat shrink type joint) for cable of size 240sqmm to 400 sqmm including dismantling / taking down unserviceable one.
Supply & Laying GI tubing 100mm bore medium grade for cable protection under road crossing including dismantling taking down unserviceable one complete all as specified and as directed .
M&L for cleaning of HT indoor cable kit at VCB end after opening VCB panel back side cable cover and bottom cable entry plate after disconnecting all cable end from busbar/CT, taking out from VCB cable chamber, checking for serviceability, cleaning & decarbonising complete cable kit and aluminium cable lugs using CTC and refixing the same to original position, with new or old nuts, bolts & washers and making cable entry point totally sealed with putty complete all as specified and as directed.. Note: Required CTC, new nuts, bolts, washers shall be inclusive of quoted rate. Serviceable cable ends will only be measured
Maintenance, servicing, cleaning of Busbur chamber of each VCB including conneting busbar from CT to Busbar, spout, support insulator, opening of covers, using CTC and clean cloth and hot air blower, checking for any loose contact, tigtening of all nuts & bolts, refixing all covers complete all as specified and as directed
Maintenance, servicing, cleaning of vacuum circuit breaker unit of each 11 KV VCB panel of capacity 400 Amps to 2500 Amps, taking out from panel, cleaning of all parts with CTC and clean cloth, removal of carbon deposited inside the moving contacts, greasing of all moving parts of the VCB, checking of complete operating mechanism for proper functioning, reporting for any defective parts, complete all as specified and as directed. Note: Replacement of defective parts of the VCB shall be measured and paid separately
Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB including necessary connection testing complete all as specified and as directed.
Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB including necessary connection testing complete all as specified and as directed.
M&L for setting of 3 ph overcurrent + earth fault numerical relays by secondary injection of current to CTs with suitable equipment for overcurrent & earth fault with high set and low set including checking of all other parameters of relays for proper tripping order after disconection of incoming or out going HT XLPE cable connection from VCB CTs and reconnection of cable ends at existing terminals after completion of relay setting complete all as specified and as directed. Note: (a) Relay setting shall be made considering corresponding values of upstream and down stream VCB relays and recorded maximum demand of VCB. Any further adjustment of values as many times require shall be carried out within the quoted rate. (b) Recovery shall be made double the quoted rate if VCB fails to trip in indicated fault and if group tripping recorded)
M&L for finding of cable fault of UG 11000 volts grade cable inside trench (under soil / drain/PCC/road/trench ) by disconnecting both cable ends, using insulation tester, cable path/fault finder and rectification complete by necessary excuvation, cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 150 sqmm to 400 sqmm, 3 core, 11000 volts grade or replacement of heat shrink indoor cable joint kit of size 150 sqmm to 400 sqmm, 3 core and reconnection of both cable end to original position after complete satisfactory insulation test, fixing with old or required new nuts-bolts-washers complete with testing complete all as specified and as directed Note: (a) Items required for rectification such as heat shrink indoor cable joint kit / heat shrink straight through joints / heat shrink sleeves and earth work shall be measured separately as material and labour . (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate. (c) Contractor shall bring necessary testing equipment and rate shall be inclusive of quoted rate.
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 800A to 1600A Schneider make 11 KV VCB. Make-Schneider only, Part No- MVIJ000980-1 complete all as specified and as directed .
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 800A to 1600A Schneider make 11 KV VCB. Make-Schneider only, Part No- MVIJ00056-01 complete all as specified and as directed .
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 800A to 2500A Schneider make 11 KV VCB. Make-Schneider only, Part No-MVIJOO157-02 complete all as specified and as directed .
Supply and fixing Schneider Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed .
M&L for painting of outer surface of multiple section of complete VCB panel 11 Kv size up to 2 m x 1.8 X 0.8 in one substation using one coat of synthetic zinc paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears complete all as specified and as directed .
S R CONSTRUCTIONS
aswitha engineering works
SATYAM ENGINEERS
GITANJALI ENGINEERING CORPORATION
VENKATESWARA ENGINEERS AND CONTRACTORS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .