Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | ₹25.7 L | L1 | Accepted-AOC ADMITTED |
| 2 | L2₹27.4 L+₹1.7 L (6.74%)Rejected-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹27.4 L+₹1.7 L (6.74%) | L2 | Rejected-AOC REJECTED |
| 3 | Rejected-Technical | - | - | Rejected-Technical REFER TECHNICAL EVALUATION DOCUMENTS |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
6 Jan 2020, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF FURNITURE YARD AND ATTACHED TOILET, WALL PANELLING , TILING AND CERTAIN WORK IN MES OFFICE AND ADMIN BUILDING AT ICGS VADINAR UNDER GE (I) CG PORBANDAR
2019_MES_306092_1
8466/19-20
Open Tender
Miscellaneous Works
Item Rate
180 days
VADINAR
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE I CG Porbandar
₹54,000
Yes
29 Feb 2020
12 Dec 2019
7 Jan 2020
12 Dec 2019
6 Jan 2020
27 Dec 2019
Amount
SCHEDULE 'A'
M&L Moorum/ red bajari filling for area development laid in layers not exceeding 25 cm thick, spread leveled and consolidated by rolling using roller as specified, including watering, complete all as specified and as directed by Engr-in-Charge. Note: Only rolled thickness shall be measured and paid
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/ disintegrated rocks complete all as specified and as directed by engineer-in-charge.
Surface excavation n.exc 30 cm deep averaging 15 cm deep and getting out in soft/disintegrated rocks complete all as specified and as directed by engineer-in-charge. .
M & L Hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed by engineer-in-charge.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed by engineer-in-charge.
M & L PCC type D2 (1:4:8, using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by engineer-in-charge.
M&L (Nominal mix) 1:1.5:3 as in foundations, including rafts, footings, foundation beams; plinth beams; base for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed by engineer-in-charge.
M&L (Nominal mix) 1:1.5:3 as in colomns, pillars, piers, posts and struts complete all as specified and as directed by engineer-in-charge.
M&L (Nominal mix) 1:1.5:3 as in beams, lintel band and gable beams complete all as specified and as directed by engineer-in-charge. .
M&L (Nominal mix) 1:1.5:3 as in chajjas complete all as specified and as directed by engineer-in-charge. .
M&L (Nominal mix) 1:1.5:3 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies ,canopies, deck slabs and in shelve and like complete all as specified and as directed by engineer-in-charge.
Supply of waterproofing compound only complete all as specified and as directed by engineer-in-charge.
M&L Pre-cast cement concrete block masonry in PCC 1:3:6 type C1 using 20mm graded stone aggregate with solid block, exceeding 10 cm in width and setting in CM 1:6 complete all as specified and as directed by engineer-in-charge.
M&L Water proofing treatment by applying one coat of oil based bituminous primer @ 0.3 kg/sqm with brush /roller, laying of minimum 3mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyster, weight not less than 3.50 kg/sqm and sealing all the over laps 100mm in length side and 100mm in width side of membranes laid with torch application complete all as specified and as directed by engineer-in-charge.
M&L Damp proof course in cement concrete 1:2:4 type B-0, 40 mm thick including necessary form work with WPC as per manufacturer instruction by weight of cement. complete all as specified and as directed by engineer-in-charge.
Formwork to sides of column footing/plinth beam etc, rough finished surfaces of concrete flat complete all as specified and as directed by engineer-in-charge.
Formwork to sides of columns, fair finished surfaces of concrete square or rectangular complete all as specified and as directed by engineer-in-charge.
Formwork to sides of beam/lintel bend and similar structure for flat fair finished surfaces complete all as specified and as directed by engineer-in-charge.
Formwork to chajjas including edges for flat fair finished surfaces complete all as specified and as directed by engineer-in-charge. .
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; fair finished not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by engineer-in-charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping, etc fair finished complete all as specified and as directed by engineer-in-charge.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by engineer-in-charge.
S&F Solid PVC door frame of size 50 mm x 47mm made out of 5 mm thick plain coloured PVC sheet reinforced with MS square tube complete all as specified and as directed by engineer-in-charge.
S&F for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tube for top/bottom rails, MS tube frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet strip of 20mm width complete all as specified and as directed by engineer-in-charge.
S & F Second class hard wood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by engineer-in-charge.
S&F 6mm thick wall paneling made up of UPVC foam profile with homogenous fine cellular structure having smooth outer integral skin, of size 200mm wide , high as per wall height with tongue and groove design for fixing on batten. The thickness at the joints is 10mm. The batten having 35mm width and 17mm thickness, The batten aligned horizontally and vertically along the wall with 50mm gap above the floor and below the ceiling. The internal batten shall be fixed 450mm centre to centre in between junction and corners. All corners, door and window seals and meeting point of floor /ceiling with paneling should cover with PVC fillets as per required dimension complete all as specified and as directed by engineer-in-charge. Make: Accucel or equivalent
S&F 100 mm size Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and as directed by engineer-in-charge.
S&F 150 mm long Aluminium anodised barrel tower bolt complete all as specified and as directed by engineer-in-charge.
S&F 150 mm long aluminium alloy handle anodised fabricated type complete all as specified and as directed by engineer-in-charge.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by engineer-in-charge.
M&L TMT steel bars 10 mm dia and above, as in reinforcement for concrete, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and as directed by engineer-in-charge. .
All as per item No 32.00 above but above 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders.
S&F Aluminium anodised window, using standard Aluminium Section with grill, Plain Sheet Glass 5mm thick, Wire mesh 0.45mm dia 1.40mm aperture including jointing cleats, glazing clips,rubber packing, anodized snap beading & fitting complete all as specified and as directed by engineer-in-charge.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete complete all as specified and as directed by engineer-in-charge.
S&F Aluminium anodised ventilator, using standard Aluminium Section with grill, Figured Glass 5mm thick, including jointing cleats, glazing clips,rubber packing, anodized snap beading & fitting complete all as specified and as directed by engineer-in-charge.
S&F Fabricate MS hold fast and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and as directed by engineer-in-charge. .
M&L GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having curled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre complete all as specified and as directed by engineer-in-charge.
M&L Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed by engineer-in-charge.
S&F Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed by engineer-in-charge.
Ditto-but to curved surface
Extra over item above for any sunk or curved moulding
M&L 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring complete all as specified and as directed by engineer-in-charge.
M & L 25 mm thick, PCC 1:2:4 type B0 (using 12.50mm graded stone aggregate) as in sub base to receive tiles complete all as specified and as directed by engineer-in-charge. .
M&L Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc set and pointed in neat cement slurry and pointed in white or coloured cement to match the surface over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by engineer-in-charge. .
M&L Glazed ceramic coloured tiles in vertical surface of size 300 x 200 x 7mm thick/450 x 250 x 7 mm set and jointed in neat cement slurry and pointed in coloured cement to match the surface over 10 mm thick rendering in CM 1:3 complete all as specified and as directed by engineer-in-charge.
M&L 75mm thick, PCC types C1 (1:3:6 , using 20mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed by engineer-in-charge.
M&L 40mm thick, PCC type B1, 1:2:4, (using 20 mm graded stone aggregate) as in floors finished cement concrete surfaces even and smooth complete all as specified and as directed by engineer-in-charge.
M&L Vitrified coloured tiles 10mm thick (square/rectangular) polished, double charged, area of each tiles not exceeding 0.36 sqm ,in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified and as directed by engineer-in-charge.
M&L 5 mm thick Rendering on ceiling on fair faces of concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by engineer-in-charge.
M&L 15mm thick Rendering on fair face of Concrete surfaces/Stone Masonry in CM 1:4 finished even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement complete all as specified and as directed by engineer-in-charge. Note ;- WPC will be measured and paid separately.
M&L 15 mm thick Rendering on fair faces of Concrete surfaces/Stone Masonry in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed by engineer-in-charge.
M&L Two coats of OBD on new plastered surface of wall over a coat of primer incl necessary preparation, complete all as specified and as directed by engineer-in-charge.
M&L Two coats of OBD on new plastered surface of ceiling over a coat of primer incl necessary preparation, complete all as specified and as directed by engineer-in-charge.
M & L Two coats of Acrylic emulsion paint over a coat of primer including preparation of new plastered surfaces of wall/ceiling complete all as specified and as directed by engineer-in-charge.
M&L Three coats of white wash on new plastered surfaces of ceiling including necessary preparation of surfaces complete all as specified and as directed by engineer-in-charge.
M&L Two coat synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and as directed by engineer-in-charge.
M&L 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by engineer-in-charge.
M&L 15mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by engineer-in-charge.
S&F 500 Ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered hoisted and fixed in position all as specified in SSR Part I including provision of 100 mm long 50mm dia Nipples with cluck nut for inlet, utlet and wash pipes complete all as specified and as directed by engineer-in-charge. Make:- Sintex or equivalent
S&F 20mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed in position complete all as specified and as directed by engineer-in-charge.
S&F 20mm dia ball valves high pressure of PTMT epoxy coated aluminium rod & high density plastic ball complete all as specified and as directed by engineer-in-charge.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls of bore 160mm (rates includes for making good disturbed surfaces) complete all as specified and as directed by engineer-in-charge.
S&F EWC double symphonic water closet pan of ivory colour (Cansino) with integrated flushing cistern complete including all fittings such as seat cover, flushing pipe, with flushing cistern (Make :- Cera Cat Pat No-S1012110-S-TRAP-110-W or equivalent) complete all as specified and directed by Engineer-in-charge.
S&F WHB of 500X420MM size and any colour of including cutting for and pinning in ends of brackets Make: CERA Cat Pat No-S2030121W or Equivalent complete all as specified and directed by Engr-in-Charge.
S&F 10 litre PVC valveless, symphonic action type flushing cistern low level with inlet valve, float and handle and PVC outlet suitable for IWC/EWC complete all as specified and as directed by engineer-in-charge. . Make:- Cera / Supermo or equivalent
M&L 15 mm dia Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe. Make: CERA Cat Pat No-F1005101 or Equivalent complete all as specified and directed by Engr-in-Charge. Make:- Cera / Supermo or equivalent
S&F 15mm dia Fancy type bib taps, chromium plated cast copper alloy Make:- CERA Cat Pat No-F1005151 or Equivalent complete all as specified and directed by Engr-in-Charge.
S&F 15mm dia Fancy type angle cock, chromium plated cast copper alloy, screwed down,high pressure, screwed both ends for iron pipe or for unions and fixed Make:- CERA Cat Pat No-F1014201 or Equivalent complete all as specified and directed by Engr-in-Charge.
S&F PVC connection 15mm dia and 300mm long with synthetic metal nut complete all as specified and as directed by engineer-in-charge.
S&F Fancy type Soap dish, CP Brass Make: CERA Cat Pat No-F5003106 or Equivalent complete all as specified and directed by Engr-in-Charge.
S&F 100mm dia grating doom of PTMT (Minimum weight 25 gms) complete all as specified and as directed by engineer-in-charge.
S&F 100 mm dia CI soil, waste and vent pipe in any length in cement joint complete all as specified and as directed by engineer-in-charge.
S&F 75 mm dia CI soil, waste and vent pipe in any length in cement joint complete all as specified and as directed by engineer-in-charge.
S&F 75 mm dia CI cowl complete all as specified and as directed by engineer-in-charge.
S & F 100 mm dia cast iron floor trap out let including jointing to waste pipe fixed in cement concrete 1:2:4 complete all as specified and as directed by engineer-in-charge.
S&F 100 mm dia CI 'P' or 'S' trap complete all as specified and as directed by engineer-in-charge.
S&F 100 mm dia CI bend (any radius) diminishing pieces etc complete all as specified and as directed by engineer-in-charge.
S&F Fancy type Toilet paper holder, CP Brass Make: CERA Cat Pat No-F5002110 or Equivalent complete all as specified and directed by Engr-in-Charge.
S&F Fancy type Tubular towel rail, 20mm dia, brass CP, 60cm long between flanges Make:- Make:- CERA Cat Pat No-F5003102 or Equivalent complete all as specified and directed by Engr-in-Charge.
M&L Soling (or sub base) with broken boulders or quarried stone, inter stices filled, spread thickness 150 mm, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed by engineer-in-charge.
M&L Rolling and consolidating formation surfaces in cutting with power roller exc. 8 tonne and n.exc. 12 tonne complete all as specified and as directed by engineer-in-charge. .
M&L Applying evenly a tack coat with paving bitumen @10 Kg per 10 Sqm preparatory to bituminous macadam complete all as specified and as directed by engineer-in-charge.
M&L 15cm thick (compacted thickness) WBM in two layers, with coarse aggregate of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required complete all as specified and as directed by engineer-in-charge. .
Preparing unsurfaced WBM by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc. complete all as specified and as directed by engineer-in-charge.
M&L 50mm thick, laying and consolidating premixed bituminous macadam, with binder content @ 4% by weight of total mix, rolled and compacted to required camber and gradient (consolidated thickness 75mm or less) with power roller exc. 8 to n.exc. 10 tonne etc. using paving bitumen complete all as specified and as directed by engineer-in-charge.
Preparing black top surfaces of roads by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc. complete all as specified and as directed by engineer-in-charge.
M&L Applying evenly a tack coat with paving bitumen @ 5 Kg per 10 SqM over WBM surfaces complete all as specified and as directed by engineer-in-charge.
M&L Bituminous premix semi dense asphaltic concrete 40mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient with 8 to 12 tonne power roller etc complete all as specified and as directed by engineer-in-charge.
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conducted FRLS cable 650/1100 volts grade drawn through and including non metallic rigid PVC medium duty concealed conduit (Minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part -I, ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modulers all as specified etc for:- Note : (i) Cost of cutting/chasing in walls and making good is deemed to be included in the unit rate quoted. Make of Cables: Havells/ Finolex/ RR Kable/ KEI. Make of PVC Pipe: PRESTO PLAST/ FINOLEX/ KALINGA/ PRECISION/ MODI/ PRINCE/ SUPREME/ POLYCAB
One light point /fan point controlled by one switch with cable 1.5 Sqmm
One 3 pin socket outlet 5 Amps on the same board with other switches with cable of size 1.5 Sqmm nominal area
One 3 pin socket outlet 5 Amps independent board with cable 1.5 Sqmm nominal area
One 3 pin socket outlet 15 Amps independent Board with cable of size 2.5 sqmm nominal area.
M&L Ceiling rose, surface type, 3 way terminal/PVC/Polycarbonate isolated body complete all as specified and directed by Engr-in-Charge. Make: HAVELLS/ CONA/ WIPRO/ANCHOR/POLYCAB WIRES PVT LTD (POLYCAB)/ CONA
S&F Modular switch 1 way, 6 Amps, 1 module (ISI marked) complete all as specified and as directed. Make: Crabtree (Athena), Havells (Oro), Anchor (Vision)
S&F Modular switch 1 way, 16 Amps, modular (ISI marked) complete all as specified and as directed. Make: Crabtree (Athena), Havells (Oro), Anchor (Vision)
S&F Modular socket, 6 Amps, 2/3 pin combined 2 modular (ISI marked) complete all as specified and as directed. Make: Crabtree (Athena), Havells (Oro), Anchor (Vision)
S&F Modular socket, 6/16 Amps, 2/3 pin combined 2 modular (ISI marked) complete all as specified and as directed. Make: Crabtree (Athena), Havells (Oro), Anchor (Vision)
S&F Modular fan regulator, 120 watt, 2 modular (ISI marked) complete all as specified and as directed. Make: Crabtree (Athena), Havells (Oro), Anchor (Vision)
M&L Sub main wiring alongwith earth wire with the sizes of 2 x4 Sqmm ,1x4 Sqmm earth wire of FR PVC insulated copper conductor, single core cable in concealed PVC conduit of 25mm dia complete all as specified and directed. Make of Cables: HAvells/ Finolex/ RR Kable/ KEI Make of PVC Pipe: PRESTO PLAST/ FINOLEX/ KALINGA/ PRECISION/ MODI/ PRINCE/ SUPREME/ POLYCAB
S&F High efficacy aluminium linear LED Batten light 20 Watt with 6500 K with driver including connecting cable from ceiling rose to light fitting complete all as specified and directed. Make : Wipro Cat No. LL20-281-XXX-65AL1 or its equivalent in Philips/Crompton
Supply and fix recessed mounting LED Luminaire housing made of pressure die cast aluminium of capacity 12 Watt THD <15% single phase including connecting cable from ceiling rose to light fittings complete all as specified and directed by EIC .Make : Wipro/PHILIPS/OSRAM/Crompton
S&F 5 Star rated ceiling fan 1200mm sweep and connecting up to and including provision of 23/0 0076 (or equivalent size in mm) flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc. complete Make Orient (Crown), CG (HS Plus), Havells (ES 50) USHA (VETRA(/ALMONARD.
S&F Sheet metal enclosure for Single pole neutral DBs when MCBs to be used 8,way 230 V double door with 200 Amps bus bar.Make:Legrand/Standard/ SURYA ROSHANI LTD/ BAJAJ/ HAVELLS / GE/ ASIAN/ANCHOR
S&F MCB single pole 240 Volts 5/6 to 30/32 amps. Make: HPL/ Sintex/ Bentec/ Legrand/ L&T/ C&S
M&L MCB single pole & neutral 240 Volts 40 Amps. Make: HPL/ Sintex/ Bentec/ Legrand/ L&T/ C&S
M&L Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point upto 7.5 mtr all as specified and indicated including testing on completion as per directed by Engr-in-Charge.(Note:- Excavation and Earthwork to be included in the quoted rate)
Supply and Laying, fixing, along the walls or passing through pipes or laid under floor or through walls etc jointing and testing , LT cross linked polythene insulated (XLPE) galvanised steel strip armoured electric cable 1100 volts grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC , of cross sectional area off size 16 Sqmm x 2 Core. Note:-Excavation, earth work, and removal will be measured and paid separately under relevant item. Make : RR Kables/L&T/KEI/Havells.
Supply and Lay, 63 mm OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor (Excavation and earthwork shall be measured and paid separately) complete all as specified and as directed by Engineer-in-Charge. Make: ALOM Poly Extrusions Ltd (ALCORR)
vijay infraprojects pvt ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .