Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹20.4 L+₹2.0 L (10.9%)Rejected-Finance 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L2 | Rejected-Finance Being not the lowest tenderer | |
| 3 | L3₹22.1 L+₹3.7 L (19.9%)Rejected-Finance | L3 | Rejected-Finance Being not the lowest tenderer | |
| 4 | L4₹24.5 L+₹6.1 L (33.1%)Rejected-Finance C 150 ADG P CHENNAI | L4 | Rejected-Finance Being not the lowest tenderer |
Tender Value
₹20.8 L
EMD Value
₹41,500
Closing Date
11 Jan 2024, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIRS REPLACEMENT OF INTERNAL WIRING LIGHT PANEL INCLUDING EARTHING LAYING OF CABLE AREA LIGHTING INCLUDING HIGHMAST STANDBY POWER SUPPLY DG SET AND WATER SUPPLY PIPE LINE PUMPSET AND CONNECTED WORKS AT TRICHY STATION UNDER GE WELLINGTON
2023_MES_633226_1
8864/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Wellington
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹41,500
Yes
2 Mar 2024
18 Dec 2023
16 Jan 2024
19 Dec 2023
11 Jan 2024
28 Dec 2023
Amount
Taking down old unserviceable copper/ aluminium point wiring (light, fan, socket or power) complete of any type (casing and capping, surface or concealed conduite, wooden batten etc), including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, wooden gutties/ rawal plug, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good to the disturbed surfaces of walls, floors, etc. complete all as specified as directed
Taking down main switches, distribution board, steel enclosure with MCB’s any way and rating including wooden board or from steel board and making good disturbed surfaces all as specified and as directed.
Taking down carefully submain wiring on wooden batten/surface conduit/casing and caping complete with its all accessories including making good disturbed surface to match the existing surface all as specified and as directed.
Point wiring complete with and including 1.5 Sqmm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade conforming to IS 694 marked with valid CML No. drawn through in existing concealed metalic / non metalic rigid PVC conduit without accessories such as bend ,tees, junction boxes etc. excluding anoised steel terminal boxes but including 3 mm thick laminated sheet covers for mounting fittings like switches, sockets and fan regulators etc with brass screws and cup washer including one run of 1.5 Sqmm PVC insulated and unsheathed multi strand FRLS copper conductor as green colour earth wire and connected to common earth dolly complete One light point controlled by one switch all as specified and directed. Note: Chases cutting where reqd will be measured and paid separtely.
All as per item No 4 hereinbefore but One ceiling fan point controlled by one switch all as specified and directed.
All as per item No 4 hereinbefore but One exhaust fan point controlled by one switch all as specified and directed.
All as per item No 4 hereinbefore but One 3 pin socket outlet 5A on independent board all as specified and directed.
All as per item No 4 hereinbefore but One 3 pin socket outlet 5A on same board all as specified and directed.
All as per item No 4 hereinbefore but One bell point controlled by one, one way push button on the same board with other switches or independent with cables 1.5 sq mm size all as specified and directed.
All as per item No 4 hereinbefore but One light point controlled by two, two way switches, with cables 1.5 sqmm size for stair case all as specified and directed.
All as per item No 4 hereinbefore but with 2.5 sq mm size PVC insulated and unsheathed 1100 volts grade single core stranded ( multistrand ) copper conductor cable for 3/6 pin socket outlet 15 amp on one independent board all as specified and directed.
All as per item No 4 hereinbefore but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed.
Wiring for circuit / sub main wiring with two runs of single core PVC insulated unsheathed cable 4.0 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 4.0 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through in existing surface / recessed steel / PVC conduit concealed metalic / non metalic conduit, accessories etc. all as specified or directed. Note: (a). Two runs of 4 sqmm as phase and neutral wire and one run of 4.0sqmm wire of green colour as earth cable shall be measured and paid as one length. (b). Proper colour coding of wires i.e. R/Y/B colour wire for Phase, Black colour wire for neutral and green colour wire for earth wire be adhered strictley executing at site.
Wiring for circuit / sub main wiring with two runs of single core PVC insulated unsheathed cable 10.0 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 10.0 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 volts grade conforming to IS 694 marked with valid CML No.and connecting to common earth drawn through in and including surface / concealed non metalic rigid PVC conduit not less than 20mm dia with all accessories such as bends, tees, junction boxes etc. all as specified or directed. Note: (a). Two runs of 10.0 sqmm as phase and neutral wire and one run of 10.0sqmm wire of green colour as earth cable and PVC Conduit shall be measured and paid as one length. (b). Proper colour coding of wires i.e. R/Y/B colour wire for Phase, Black colour wire for neutral and green colour wire for earth wire be adhered strictley executing at site.
Switch piano, flush type single pole, one way 5/ 6 Amp, 240V, 50Hz AC supply, ISI marked all as specified and directed
Switch piano, flush type single pole, one way 15/ 16 Amp, 240V, 50Hz AC supply, ISI marked all as specified and directed
Supply socket combination (multi purpose) 2 in 1, 3 Pin, 5/6 Amp flush type universal suitable for 230V, 50Hz AC supply, ISI marked all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal suitable for 230V, 50Hz AC supply ISI marked all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten / angular fittings all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20Amps MCB complete all as specified and directed at site all as specified and directed.
Ceiling rose, PVC polycarbonate isolated body with three terminals complete all as specified and directed.
Bell push ,Flush type, single pole 5/6 Amps complete all as specified and directed.
Switch piano flush type single pole two way 6Amps complete all as specified and directed.
Supply and fix inverter LED batten with square profile, polycarbonate channel and decorative box type with driver consisting Lithium ion battery with charging time 8hours -10 hours and back up time upto 4 hours minimum suitable for 220V, 50Hz, AC supply to be incorporated under item No. 32 hereinbefore for repairs all as specified and directed. Make: Havells cat Part No. LHEXACP7FN1W020 or other equivalent in specifications of Bajaj/Philips/Crompton/Wipro etc.
Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack to be incorporated under item No. 32 hereinbefore for repairs all as specified and directed. Make: Havells cat Part No. LHEXACP7IN1W010 or other equivalent in specifications of Bajaj/Philips/Crompton/Wipro etc.
MCBs with DB's sheet metal enclosures TPN 4 way 415 Volt with 200 Amps rated bus bar and Double Door Type following type/ cap complete all as specified and directed
MCB DB double door type, SPN of 8 way 200 Amps rated bus bar 240 Volt ISI marked, IP-43 all as specified and directed
MCCB / isolator TPN 415 Volts of capacity 63 Amps, 'C' curve, 25kA complete all as specified and directed.
MCB SPN 240 volts of capacity 40Amps to 63Amps complete all as specified and directed.
MCB's single pole 6 Amps to 32 Amps, 'C' curve, 10kA, 240 Volts all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings including LED 3 Star rating Bulb 9Watt suitable for B22 all as specified and directed.
LED light fitting 36Watt having 6500K of 2' x 2' panel, ultra slim recess mounted edge type with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling with ceiling cutout (583 x 583)mm and height 9mm including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Earthing complete with GI earth plate electrode 60x60cmx6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 4mm dia protected by GI pipe light grade 15mm dia and connected to panel board / DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 cover slab, reinforcement with 6mm dia MS bars at 100mm dia both ways, MS hook 6mm dia MS bars etc complete all as specified and directed.
Switch socket combination multi purpose 2 in 1, 3 Pin, 5 Amp 230V, 50Hz AC, ISI marked including fixed in repairs all as specified and directed.
Modular switch in lieu of supply and fix modular type switch 6 amps one module including fixed in repairs all as specified and directed.
Modular socket in lieu of supply and fix modular type multi purpose socket 6 amps two module including fixed in repairs all as specified and directed.
Modular switch in lieu of supply and fix modular type switch 16 amps one module including fixed in repairs all as specified and directed.
Modular socket in lieu of supply and fix multi purpose socket 16 amps 2 module including fixed in repairs all as specified and directed.
Modular regulator in lieu of supply and fix modular type fan regulator 120 W 2 module including fixed in repairs all as specified and directed.
Bell Multi Music type call bell suitable for 230 volts single pole all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation of pole or laying of cable trench, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick using soils all as specified and directed.
Removing the surplus soil to a distance not exceeding 50 meters from the starting point and depositing at a height not exceeding 1.5 m above ground level all as specified and directed.
Supply, Laying, testing and commissioning in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with mulktistranded aluminium conductor 1100 volts grade having cross sectional area size of 120 Sqmm 3.5 core laid in trenches / ducts/ fixed to wall/ pole/ inside LT panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed. Note:- (I) Earth wk, i.e exc, RFR, removal, sand cushioning, brick / PCC required for laying in trenches will be measured and paid separtely.
All as per item No 45 hereinbefore but of size 95sqmm and 3.5 core all as specified and directed.
GI tubing light grade, ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches suitable for the following size of pipes 80 mm dia all as specified and directed.
GI tubing light grade, ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches suitable for the following size of pipes 40 mm dia all as specified and directed.
Supply and lay in trenches reinforced precast concrete cable cover class LV type I, flat size 250x150x40mm for cable protection all as specified and directed.
Sand cushioning to PVC cable with using riddled sand obtained from excavation or river sand gently punned below / around cable all as specified and directed. Note: Punned thickness only will be measured and paid.
Supply and fix in replacement MCCB of capacity 100 Amps, 415 Volts, AC, four pole of 25 KA breaking capacity and taking out old unserviceable MCCB and keeping in safe custody to issue under schedule of credit all as specified and directed.
Supply and fix in replacement MCCB of capacity 63 Amps, 415 Volts, AC, four pole of 25 KA breaking capacity and taking out old unserviceable MCCB and keeping in safe custody to issue under schedule of credit all as specified and directed.
Supply and fix in replacement MCCB with thermal magnetic protection unit of capacity 200 Amps, 415 Volts, AC, four pole of 25 KA breaking capacity, thermally adjustable from 0.8 to 1In and taking out old unserviceable MCCB and keeping in safe custody to issue under schedule of credit all as specified and directed.
Supply and fix in replacement MCCB with thermal magnetic protection unit of capacity 400 Amps, 415 Volts, AC, four pole of 25 KA breaking capacity, thermally adjustable from 0.8 to 1In and taking out old unserviceable MCCB and keeping in safe custody to issue under schedule of credit all as specified and directed.
Supply and fix in replacement MCB TPN ranging from 40 Amps to 63 Amps, 415 Volts, AC, 10 KA breaking capacity, and taking out old unserviceable MCCB and keeping in safe custody to issue under schedule of credit all as specified and directed.
Supply and installation in replacement of steel tubular swaged poles type 410 SP-22 (8.5 mtr long) complete with CI base plate and final taper plug, bolts, nuts and screws as specified including necessory PCC foundation and copping all as specified and directed.
Painting of zebra patta to RCC / Steel tubular poles ,at bottom portion with black and white paints up to height 1.2 metre in alternate strip manner (width of strip not more than 30cm) and writing MES Nos on LT Poles with black paint in capital letters of size 4cm height and 2 cm wide such as “LT-1, LT-999” with black or white back ground circle of not less than 16 cm complete all as specified and as directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling of light poles and stays etc all as specified and directed.
Plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling of light poles and stays etc all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded stone aggregate for pedestal including necessary formwork finished fair using extra cement all as specified and directed.
Cutting the existing bituminous surface road / concrete floor and including returning filling and making good using PCC 1:3:6 type C1 using 20mm graded stone aggregate 300mm thick to match with the existing surface complete all as specified and as directed.
Earthing complete with GI earth plate electrode 60x60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip of size 32x6mm by means of bolts and nuts washers mesh out of GI and earth strip protected by Galvanized pipe light grade 40mm bore, 20 mm bore medium grade for watering purpose and connected to main control board all as shown in Electrical plate No. 3 of SSR Part-1 including necessary earth work and excavations in any type of soil strata, PCC 1:2:4 type B1 Chamber with 40mm thick, RCC 1:2:4 cover slab with 6mm dia MS bars etc complete all as specified and directed. Note: Strip/wire beyond 7.5 mtr in length shall be measured and paid seperately.
Dismantling and taking down street light fittings LED / T5 / T L fitting / Solar light fitting / MH fitting / HPSV / HPMV of any type, wattage and make from pole / wall by disconnecting all electrical / mechanical connections incl nuts, bolts, washers, battery boxes, battery terminals etc for repairing from any height. Repairing by split opening the same in to the parts for fault finding, testing and fixing back at the same location complete after replacement of unserviceable spares as LED driver, connectors, LED lamp of any capacity including top up of distilled water of solar LED fitting batteries including cleaning of covers, solar panel, fixing insulation sleev to the worn out insulation / bare cable conductor by insertion of insulation sleev etc complete all as specified and directed. Note: (a) Cost of minor spares such as cotton waste, nuts, bolts, washers, passivated bolts, lugs, battery terminals, distilled water for top up and grease for battery terminals etc deemed to be considered in quoted rates. (b) Cost of LED driver, solar battery box, wire for service connetion will be measured and paid separetly under Supply only items.
Supply only LED driver as per IS 15885 (Part2 / Sec 13) suitable for LED street light fittings from 24W to 40W alongwith PCB in white light color, Input voltage 110-265V, AC, 50/60Hz and output 30-40V/600mA, with driver power factor not less than 0.95 and IP 65 protection all as specified and directed.
Supply only Low maintenance - long life tubular type battery suitable for solar street light fittings of rating 12V and 150Ah all as specified and directed. Make: Exide cat part No. 6LMS150L or other equivalent in Livguard/ Luminous/ Amaron
Supply only PVC Solar street light battery box not less than 2mm thickness all as per site requirement but size not less than 520mm x 230mm and height 280mm including necessary mounting hardware materials such as nuts, bolts, washers etc all as specified and directed.
Supply and fixing in replacement LED Building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
LED street light fitting of 60 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified or directed.
Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Solar panel based LED light fitting of 15 watts operating with DC Power Supply and keeping old fitting aside in safe custody to issue under Schedule of credit complete including replacement all as specified and directed
PVC junction box sheet moulding compound type with hinged type door locking arrangement, white colour of size 200x100x105mm (out door type) with MCB SP 6Amps fixing in the box complete including replacement all as specifed and directed.
Supply, installation, testing and commissioning in replacement digital time switch with astronomical function for switching ON/OFF street light fittings and other electric devices having 1 output 16Amps, 250V AV, 50/60Hz including taking out old unsv time switch of any type, make, rating and keeping aside in safe custody to issue under sch of credit all as specified and directed. Make: Legrand, Cat Part No. 4126 57 or other equivalent make in L&T / Hager Philips / C&S
Street light bracket made out of 40mm dia medium grade GI tubings of 1.5Mtr long bend to requisite shape including two MS flat iron clamp made out of 20x3mm and all fixing arrangements such as nuts, bolts, washers etc to fix with RCC / Steel Sewaged / Octagonal or any other type of pole incl taking out old bracket and keeping aside in safe custody to issue under Sch of credit all as specified and directed.
LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, dismantling old unsv flood light fitting and keeping aside in safe custody to issue under sch of credit all as specified and directed. Make: Bajaj/ Havells/ Surya/ Wipro
Supply and fix in replacement on load change over switch of rated current of 100 amp capacity 415 volts, 50 Hz C-line, direct handle F1, manual changeover suitable for open execution type in existing panel including dismantling existing old burnt changeover switch all as specified and directed. Make: L&T type C01-100 and Cat Part No CO11000OOOO or other make of equivalent capacity.
Taking out / up / down from trenches / walls / floors etc of galvanised iron tubings of 15mm dia bore alongwith GI accessoried i.e. socket, elbow, union, flange, coupling, taps etc including branch connections all as specified and directed.
Taking out / up / down from trenches / walls / floors etc of galvanised iron tubings of 20mm dia bore alongwith GI accessoried i.e. socket, elbow, union, flange, coupling, taps etc including branch connections all as specified and directed.
Taking out / up / down from trenches / walls / floors etc of galvanised iron tubings of 25/ 32mm dia bore alongwith GI accessoried i.e. socket, elbow, union, flange, coupling, taps etc including branch connections all as specified and directed.
Taking out / up / down from trenches / walls / floors etc of galvanised iron tubings of 40/ 50mm dia bore alongwith GI accessoried i.e. socket, elbow, union, flange, coupling, taps etc including branch connections all as specified and directed.
Taking out / up / down from trenches / walls / floors etc of galvanised iron tubings of 80/ 100mm dia bore alongwith GI accessoried i.e. socket, elbow, union, flange, coupling, taps etc including branch connections all as specified and directed.
Galvanised iron/ steel (Gl) tubings of 20mm dia bore laying in trenches medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron/ steel (Gl) tubings of 25mm dia bore laying in trenches medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron/ steel (Gl) tubings of 40mm dia bore laying in trenches medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron/ steel (Gl) tubings of 50mm dia bore laying in trenches medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron/ steel (Gl) tubings of 80mm dia bore laying in trenches medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed. Note for Item No 81 to 85: (a) Necessary excavation and earth work required of laying will be measured and paid separately under relevant items of BOQ. (b) Suitable size of union / flanges will be provided at all branches tees, joints, gate valves and at interval of 30RM of straight pipes or as per site requirement or where directed by the Engineer-in-charge and rate for the same deemed to included in the rate quoted above for ease in maintenance.
Galvanised iron / steel (GI) tubings 15mm dia bore medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) and fixing in wall complete with clips, wall hooks, wooden plugs etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron / steel (GI) tubings 20mm dia bore medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) and fixing in wall complete with clips, wall hooks, wooden plugs etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron / steel (GI) tubings 25mm dia bore medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) and fixing in wall and floor complete with clips, wall hooks, wooden plugs etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron / steel (GI) tubings 80mm dia bore medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) and fixing in wall and floor complete with clips, wall hooks, wooden plugs etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed.
Galvanised iron / steel (GI) tubings 100mm dia bore medium grade with screwed and socket joints, together with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, flanges etc.) and fixing in wall and floor complete with clips, wall hooks, wooden plugs etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good all as specified and directed. Note for Item No 86 to 90: Suitable size of union / flanges will be provided at all branches tees, joints, gate valves and at interval of 30RM of straight pipes or as per site requirement or where directed by the Engineer-in-charge and rate for the same deemed to included in the rate quoted above for ease in maintenance.
Gun metal globe or gate valve, 15mm bore dia heavy duty conforming to IS-778 with iron wheel head screwed both ends suitable for fixing to GI tubings including necessary fittings as required at site and dismantling, taking out old unserviceable valve and keeping aside in safe custody to issue under Sch of Credit including fixed in repairs all as specified and directed.
Gun metal globe or gate valve, 20mm bore dia heavy duty conforming to IS-778 with iron wheel head screwed both ends suitable for fixing to GI tubings including necessary fittings as required at site and dismantling, taking out old unserviceable valve and keeping aside in safe custody to issue under Sch of Credit including fixed in repairs all as specified and directed.
Gun metal globe or gate valve, 25mm bore dia heavy duty conforming to IS-778 with iron wheel head screwed both ends suitable for fixing to GI tubings including necessary fittings as required at site and dismantling, taking out old unserviceable valve and keeping aside in safe custody to issue under Sch of Credit including fixed in repairs all as specified and directed.
Gun metal globe or gate valve, 50mm bore dia heavy duty conforming to IS-778 with iron wheel head screwed both ends suitable for fixing to GI tubings including necessary fittings as required at site and dismantling, taking out old unserviceable valve and keeping aside in safe custody to issue under Sch of Credit including fixed in repairs all as specified and directed.
Supply and fix in replacement 100mm dia CI body foot valve confirming to IS : 4038, Ball type, heavy duty suitable for GI tubings alongwith necessary fittings such as flanges, GI Hex nipple (double nipple), rubber packing etc as per site requirement including taking out old unserviciable foot valve any type, make from suction pipe from semi-underground sump of Pump set all as specified or directed.
Supply and fix in replacement 80mm dia CI body foot valve confirming to IS : 4038, Ball type, heavy duty suitable for GI tubings alongwith necessary fittings such as flanges, GI Hex nipple (double nipple), rubber packing etc as per site requirement including taking out old unserviciable foot valve any type, make from suction pipe from semi-underground sump of Pump set all as specified or directed.
Supply and fix in replacement 50mm dia CI body foot valve confirming to IS : 4038, Ball type, heavy duty suitable for GI tubings alongwith necessary fittings such as flanges, GI Hex nipple (double nipple), rubber packing etc as per site requirement including taking out old unserviciable foot valve any type, make from suction pipe from semi-underground sump of Pump set all as specified or directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip all as specified and directed.
Testing of water sample collected from the takenover point at Det trichy area reynolds road, alexandria road,117 Inf Bn (TA) unit and mannarpuram and tested in an authorised state government lab and obtained the water testing report and submitted to the AGE (I) office as directed by the Eng-in-Charge. Note: 2/5 Ltr Bottles required for collecting the sample need to be provided by the contractor.
Costruction of valve pit chamber of size 900mm x 900 mm x 900 mm (internal size) with 4 mm thick MS sheet cover made out of Fe 410 -W (GdeE- 250) qualityA having 4mm thick and angle iron 50 x50 x6 mm thick frame embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation removal of surplus soil to a distance not exceding 50 mtr returning filling in PCC 1:4:8 type D2, 75 mm thick as in foundation/floor brick work (one brick thick) in cement mortars (1:4) PCC 1:3:6 type C1 in copping, Plastering in cm 1:4 and 75 mm thick hard core below foundation complete etc including dismantling old valve pit chamber complete all as specified and directed.
Costruction of valve pit chamber of size 1000mm x 1000 mm x 1000 mm (internal size) with 4 mm thick MS sheet cover and angle iron 50 x50 x6 mm thick frame embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation removal of surplus soil to a distance not exceding 50 mtr returning filling in PCC 1:3:6 type C2 75 mm thick as in foundation/floor brick work (one brick thick) in cement mortars (1:4) PCC 1:3:6 type C1 in copping, Plastering in cm 1:4 and 75 mm thick hard core below foundation etc including dismantling valve pit chamber complete all as specified and directed.
Supply and fix non return valve flanged with by pass arrangements heavy duty class -I 80mm bore conforming to IS including rubber gaskets, bolts, nuts, and washers and dismantling taking out old unserviciale NRV including cutting unscrewing old nut bolts complete all as specified and directed.
Supply , fixing and testing 80mm bore sluice valve flanged and drilled both ends CI body, heavy duty, class PN 1:6 gun metal spindle conforming to IS 14846 including jointing with and including rubber gaskets, bolts, nuts, and washers complete and dismantling taking out old unserviciale sluice valve including cutting unscrewing old nut bolts complete all as specified and directed.
Supply , fixing and testing 100 mm bore sluice valve flanged and drilled both ends CI body, heavy duty, class PN 1:6 gun metal spindle conforming to IS 14846 including jointing with and including rubber gaskets, bolts, nuts, and washers complete and dismantling taking out old unserviciale sluice valve including cutting unscrewing old nut bolts complete all as specified and directed.
Disconnecting the electrical and mechanical connections of burnt mono block pump set / electrical motors of 10/15HP, 3 phase from the site / location including transporting to and from to work shop. Rewinding of electrical motors by dismantling and removing the burnt out copper winding wire cleaning the slots of stator with petrol and brushes winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles, turning and polishing to the shaft and / or rotor, including replacement of suitable bearing etc complete stator/rotor after rewinding re-assembling all parts including re-installing connections to original position and testing on full load all as specified and directed.
Taking out / lifting & loweing the submersible pump set upto 5 / 7.5 HP from deep bore well with connected cable and column pipes and disconnecting the cable for removing the submersible pump set for carrying out minor repairs and re-assembling column socket pipe end and testing and commissioning of pump set after necessary repairs including rectification of any leakage to entire satisafaction all as specified and directed.
Rewinding of AC three phase induction motor upto 7.5 HP(Submersible motor) by cutting of burnt winding, cleaning of stator slots, cleaning bleaching of motor and rewinding Rewinding of electrical motors by dismantling and removing the burnt out copper winding wire cleaning the slots of stator with petrol and brushes winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles, turning and polishing to the shaft and / or rotor and including servicing of pumps complete all as specified and directed.
Supply and connect PVC insulated PVC sheathed submersible multi stranded copper conductor flat cable 3 core 10 sq mm 1100 volts grade ISI marked including disconnecting dismantling taking out old unserviceable cable from LT panel to pump set all as specified and directed.
Supply and replacement of water level indicator for over head tanks including all ball, rope, pulley and level indicator as per site requirement complete all as specified and directed.
Carrying out of air compression testing of existing borewell of 150mm dia with PVC casing pipe with depth 300feet after disconnecting electrical & mechanical connections and taking out the submersible motor pump set of 2HP/5HP, 3phase, 415V, AC alongwith 50mm dia GI tubings and their fittings, keeping submersible motor pump set alongwith GI tubings, GI fittings, electrical cable aside in safe custody to re-use for lowering the submersible motor pump set after necessary borewell compression and yield testing complete in all respect. Compression of borewell should be carried out continuously not less than 10hours. All T&P, diesel for DG set/vehicle for carrying air compressor & DG set, air pipe for compressed air, drain pipe or other requisite T&P etc required for compression and yield testing of borewell should be arraged by contractor at his own arrangments. Making electrical connections and mechanical connections for lowering of submersible motor pump set alongwith 50mm dia GI tubings and carry out necessary testing of submersible motor set after lowering complete all as specified and directed and also submit yield testing report for records. Note: (a) Cost of all requisite T&P and material required for taking out submersible motor pumpset, compression & yield testing of borewell and lowering of submersible motor pumpset deemed to be included in the quoated rates and no any extra amount will be paid. (b) Cost of minor spares i.e. cotton waste, GI fittings (socket, union, elbow etc), yarn & sealent for jointing 50mm dia GI tubing, rubber packing required for connecting and lowering of submersible motor pump set deemed to be included in the quoated rates.
OH tank and UG sump man hole cover Made out of mild steel 3.15 mm thich sheets and frame 25 mm angle 6 mm thick includung handle, hinges and locking arrangement complete all as specified and directed.
M Govindarajan
p.chinnasamy
S.RAMACHANDRAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .