| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC 354 SIRAJ MONDAL ROAD KANCHRAPARA 24 PGS N | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.6 L+₹7,727 (5.19%)Rejected-AOC 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L2 | Rejected-AOC L2 | |
| 3 | L3₹1.8 L+₹31,440 (21.1%)Rejected-AOC 1260 GANGAPUR GROUND FLOOR MANDIRTALA DUTTAPUKUR NORTH 24 PARGANAS WEST BENGAL 743248 | 24 PARAGANAS NORTH | WEST BENGAL | 743248 | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹3,577
Closing Date
11 Nov 2024, 2:00 pmClosed
ASSISTANT ENGINEER P.W.D
OFFICE OF THE ASSISTANT ENGINEER P.W.D BARASAT ELECTRICAL SUB DIVISION SUB STATION BUILDING, HATIPUKUR BARASAT NORH 24 PARGANAS
Upkeepment of Electrical and allied installation work with provision of material....at Govt. College of Education, Banipur, North 24 Parganas --- Illumination of college compound including various paths of Boys and Girls hostel and staff quarters.
2024_WBPWD_766533_1
67/T of 24-25 of AE/BESD
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Banipur
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,577
9 Dec 2024
30 Oct 2024
13 Nov 2024
30 Oct 2024
11 Nov 2024
30 Oct 2024
Amount
Supplying and fixing 32 A, 240V DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall.(make- L&T /Havells /Siemens)
Supply & Fixing Submersible Pump Control Stater with Three Phase Preventer providing Volt/AMP Meter,ON/OFF Push stater , contractor with will relay unit,Indicator complete in steel metal enclosure on wall suitable for 6 HP DOL starter. (Make- L/T) MK-1 DOL Starter Relay Amps range 6A to 10A.
Supplying and fixing 415V, 32 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supply & Delivery of PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR Kabel/Havells/KEI ] a) 2 core 6 sqmm
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
S&F of compression type gland complete with brass gland, rubber rings for dust & moisture proof entry of PVC armoured cables as below as per G.S. a) 2 core 6 sqmm
Finishing the ends of following cables by crimping method including S/F dowells solderless sockets, tapes and jointing materials etc. as per G.S. a) 2 core 6 sqmm
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe with excavation of Soft soil
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages, No. 8 SWG
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) in 20mm size PVC rigid conduit 'FR' (Precision make) on wall incl. necy. fittings as required necy. fittings as per GS as required :-(Make: Polycab/Finolex/Gloster/RR Kabel/KEI) I) 2 x 1.5 sqmm + 1 x 1.5 sqmm ECC
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. as per GS.
Supply & Delivery of 90W Street light luminaire (IP 66) with peanut lens and high poer LED to ensure uniform distribution and higher spacing between poles, 10 KV SPD, THD<10%, PF> 0.95, BIS approved silicon filled potted driver, minimum LPW : 110 lumen/watt and minimum system output 9900 lumen suitable for use with 230 Volt, 50 Hz. ( Make - Phillips/Crompton/Havells/ Wipro)
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.
Supplying & fixing medium gauge 40 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
M/S R. K. ENTERPRISE (BID ID -5744369)
S D ENTERPRISE (BID ID -5745204)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .