Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.3 L+₹7.4 L (19.6%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹48.8 L+₹11.0 L (29.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical NO Remarks on work load return |
Tender Value
₹42.7 L
EMD Value
₹85,440
Closing Date
30 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
g
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF ACs AT VARIOUS MESSES OF VSN CHILODA UNDER GE (AF) CHILODA
2024_MES_642948_1
8119/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
VAYU SHAKTI NAGAR CHILODA
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹85,440
Yes
20 May 2024
17 Feb 2024
1 Apr 2024
17 Feb 2024
30 Mar 2024
7 Mar 2024
17 Feb 2024 - 1 Mar 2024
Amount
Supply , install high wall split type air conditioner unit indoor and out door unit complete with cordless remote control unit and with in built air ioniser and plasma filter for batter indoor air quality and EER 3.2 of cap 1.5 ton inverter type 5 star of make Daikin or eqivalent of Voltas/bluestar complete all as specified and directed. (Note: Quotated rate to be inclusive of outdoor unit stand, 3 meter of copper pipe and drain pipe, extra copper pipe if required will be paid under relevant items of this schedule)
Supply , install high wall split type air conditioner unit indoor and out door unit complete with cordless remote control unit and with in built air ioniser and plasma filter for batter indoor air quality and EER 3.2 of cap 2.0 ton inverter type 5 star of make Daikin or eqivalent of Voltas/bluestar ccomplete all as specified and directed. (Note: Quotated rate to be inclusive of outdoor unit stand, 3 meter of copper pipe and drain pipe, extra copper pipe if required will be paid under relevant items of this schedule)
M&L for concealed sub main wiring complete with PVC insulated FRLS cable of single core 04 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVC casing capping/ Conduit with accessories incl 4 Sqmm unsheathed multi standard FRLS copper conductor as earth wire complete all as specified and directed. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length.
M&L for concealed sub main wiring complete with PVC insulated FRLS cable of single core 2.5 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVC casing capping/ Conduit with accessories incl 2.5 Sqmm unsheathed multi standard FRLS copper conductor as earth wire complete all as specified and directed. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length.
S&F Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened,PVC Bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed.
S&F Sheet metal enclosure (Factory made) for distribution board 4 way double door (when MCBs are to be used) TPN 415 volts with 200 Amp rated busbar complete all as specified and directed.
S&F MCB SP 6 to 32 Amp 10 KA complete all as specified and directed.
Supply & fix MCB SPN 5 to 32 Amps 10 KA complete all as specified and directed.
Supply & fix MCB TPN, 40 to 100 Amp 10 KA complete all as specified and directed.
M&L for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to 4.00 mm as earthing lead, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore GI pipe light grade for earth protection including all excavation earth work in any type of soil, PCC pit with RCC pit cover charcoal salt, funnel complete all as shown in the electrical plate no 3 of SSR part-1.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and directed.
Returning, filling including spreding, leveling watering and well ramming in laying not exc. 25cm for soft/ loose soil complete all as specified and as directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed.
Supply and lay DWC pipe of size ODxID 77x63 of IS-16205 (Electrical cable use) for providig protection to cable laid in trenches complete all as specified and as directed by Engineer In Charge.
Labour only for boring under road/drain by manual method for inserting the DCW pipe 80 mm dia for cable protection complete all as specified and directed by Engineer In Charge.
S&F copper tubing of size 5/8" with nitrile rubber armor complete all as specified and as directed.
S&F copper tubing of size 1/2" with nitrile rubber armor complete all as specified and as directed.
S&F copper tubing of size 1/4" with nitrile rubber armor complete all as specified and as directed.
S&F drain pipe PVC, 3 mtr in length, suitable for split AC of cap 1.5/2.0 TR complete all as specified and as directed.
ARTI CONSTRUCTION
Dighard Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .