Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹24.5 L+₹4.7 L (23.8%)Rejected-Finance VILL LANGU P O GANDHIGRAM TEH BAIJNATH DISTT KANGRA H P | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹24.8 L+₹5.0 L (25.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹26.3 L+₹6.5 L (33.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹26.4 L+₹6.6 L (33.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Sept 2024, 6:00 pmClosed
GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair/replacement of internal wiring and allied works of Officers Accn and Repair/Maint of geysers, exhaust fans, ceiling fans, wall mounted fans at YOL CANTT under AGE E/M of GE (KH) YOL
2024_MES_668301_1
GE/Y-58/2024-25
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (KH) YOL
₹80,000
Yes
3 Oct 2024
30 Aug 2024
20 Sept 2024
30 Aug 2024
18 Sept 2024
13 Sept 2024
Amount
PART-I:- Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including light fiitings any type, switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, tube light fitting, regulator etc. and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes, complete all as specified and directed.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified and directed.
Point wiring with 1.50 Sqmm copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including concealed PVC conduit medium grade, ISI marked of suitable size with all fittings/ accessories such as bends, cross, elbow, tees etc. of suitable size and also including PVC insulated ISI marked unsheathed 1.50 Sqmm copper multistranded conductor FLRS as phase, neutral and earth wire connected to common earth dolly and including concealed MS pressed steel (modular sunken box) of suitable sizes terminal boxes made from 1.60mm thick sheet for mounting of switches, sockets, fan regulators, light fittings etc. and modular cover plate as top cover (ISI marked) for one light point or one fan/exhaust fan point or one bell point, independent, controlled by one way switch/ push button complete all as specified and directed. Note:- (i) Wiring colour code i.e Red/Yellow/Blue for phase, Black for neutral and Green for earth shall be maintained. (ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate. (iii) Point wiring is considered for modular switches and sockets. Rate of metallic sunken box and other connected accessories required for modular point wiring included in quoted rates. (iv) Rate of modular switch and sockets will be paid seperately under relevant item.
All as per serial item No '03' above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per serial item No '03' above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per serial item No '03' above, but for 3 pin 15 amps socket out let on independent with 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed.
All as per serial item No '03' above, but for one light point controlled by two way switchs.
M & L for point wiring with 1.50 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including PVC junction box /MS pressed steel cadmium plated terminal box not less than 1.60 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated hylam sheet top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.50 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/ fan point controlled by one switch Note : (i) Wiring Colour code i.e. Red/Yellow/Blue for Phase, Black for neutral and Green for earth shall be maintained. (ii) Chase cutting if required shall be measured and paid separately under relevant items in this schedule.
All as per serial item No '08' above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per serial item No '08' above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per serial item No '08' above, but for 3 pin 15 amps socket out let on independent with 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed.
All as per serial item No '08' above, but for one light point controlled by two way switchs.
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and directed.
Supply and fix modular switch piano flush type one way 6 Amps, 1 module, 230V, Fixed, complete all as specified and directed.
Supply and fix modular switch piano flush type one way 16 Amps, 1 module, 230V, Fixed, complete all as specified and directed.
Supply and fix modular switch piano flush type two way 6 Amps, 1 module, 230V, Fixed, complete all as specified and directed.
S&F Modular socket 6 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
S&F Modular socket 6/16 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
Supply and fix modular bell switch 6 Amps, 1 module Fixed, complete all as specified and directed.
S&F Modular fan regulator step type 100 Watt one module 230 volts, complete all as specified and directed.
Ceiling rose, surface type 3 terminals 65x20mm, fixed in repair, complete all as specified and directed.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, fixed in repair, complete all as specified and directed.
Supply and fixed in repair LED Bulb 9 watt, cool/warm white 6500K/3000K, suitable for base B22/E27, 230V, complete all as specified and directed.
Supply and fixed in repair LED invertar Bulb 12 watt, cool/warm white 6500K/3000K, suitable for base B22/E27, 230V, complete all as specified and directed.
Supply and fix in repairing LED Adore 2.8 W having base suitable for B22/ E27/ E14 holder CDL Candle Lamp, WW/ CDL, 6500/3000 K, 230 volts complete all as required at site and directed by Engr - in - Charge. Make:Havells / Polycab/Bajaj /CG
Supply and fix in repair modular Bell Push with indicator 6 Amps, 1 module including all As per existing make complete all as specified and directed by Engr-in- Charge.
Supply and fix in repair modular fan step regulator, 2 Module including all As per existing make complete all as specified and directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 1 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
Supply and fix modular cover plate with frame, 3 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
Supply and fix modular cover plate with frame, 8 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
Supply and fix modular cover plate with frame, 10 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
Supply and fix modular cover plate with frame, 12 module including all As per existing make complete all as specified and as directed by Engr-in- Charge
Single pole and neutral sheet metal enclosure with a two pin and earth plug top and socket complete with one double pole MCB 20 Amps, fixed in repair, complete all as specified and directed.
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed.
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 12 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed.
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface, complete all as specified and directed.
M & L for vertical DB iron clad factory made TPN 4 Way, MCCB as incomer and MCB SP as out going, double door DB IP 43 protection level, incl Blanking plate, lugs etc complete and neutral link with one MCCB 4 pole 415V 100 Amps rating with rupture capacity 16KA incl connection, fixing flushed to wall, necessary grouting, making good with CM 1:4 and painted to match exisitng wall color, complete all as specified and directed. (outgoing MCB will be measured seperately)
MCB SP 6 to 32 Amp, 240 Volts, 10 KA, C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB SPN 32 Amp, 240 Volts, 10 KA C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB SPN 63 Amp, 240 Volts, 10 KA C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB TPN 63 Amp, 415 Volts, 10 KA C series including taking out old, complete all as specified and directed. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
S & F MCB, 4 Pole, 63 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
S & F MCB, 4 Pole, 100 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring, complete all as specified and directed. Note:- (i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface casing caping medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring, complete all as specified and directed. Note:- (i) One run of PVC casing caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring, complete all as specified and directed. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface casing caping medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring, complete all as specified and directed. Note :-(i) One run of PVC casing caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
Replacement of LED Decorative ultra slim square profile LED lighting integral type fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, 10 watt LED, 230V, and making connection with 2 core copper twisted flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light, complete all as specified and directed.
Replacement of LED Decorative ultra slim square profile LED lighting integral type fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, 20 watt LED, 230V, and making connection with 2 core copper twisted flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light, complete all as specified and directed.
LED tube light fitting integral type 1x20W, 230V, LED tube light fitting invertar light (cool day light, normal white and warm white in one fitting) 4 hours backup with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, incluing taking out old light fitting any type, complete all as specified and directed.
Supply and fixing of bldg security light 30 Watt New generation energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source and lens enbedded PC cover having TOP opening seperate toughtned glass/verminproof driver compartment, SPDs with IP66 protection and impact resistance of IK07, suitable for pole dia 43mm (max) connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of size 32mm dia lenght 1.20m along with clamps, including taking down old light, complete all as specified and as directed.
Supply and fixing decorative wall light fixture made up of polycarbonate, with 9W LED invertar lamp B22 base with 4 hours backup complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, including taking out old light, complete all as specified and directed.
Supply and fix in repair modular switch piano flush type one way 6 Amps, 1 module, 230V, complete all as specified and directed.
Supply and fix in repair modular switch piano flush type one way 16 Amps, 1 module, 230V, complete all as specified and directed.
Supply and fix in repair modular socket out 6/16 Amps, 5 pin, 2 module, 230V, complete all as specified and directed.
Supply and fix in repair modular Bell switch 6 Amps, 1 module, 230V, complete all as specified and directed.
Supply and fix in repair modular socket out 6 Amps, 3 pin, 2 module, 230V, complete all as specified and directed.
Supply and fix in repair modular step type fan regulator, 1 Module, 100 Watt, 230V, complete all as specified and directed.
Material and labour for PVC Casing & Caping of size (20 x 12) mm ISI Marked suitable for electrical wiring, complete all as specified and directed.
Material and labour for PVC Casing & Caping of size (26 x 16) mm ISI Marked suitable for electrical wiring, complete all as specified and directed.
Material and labour for uPVC electrical conduit pipe of size 20mm dia (heavy duty) Ivory color ISI marked suitable for electrical wiring including junction box, tees and bends etc, complete all as specified and directed.
Material and labour for uPVC electrical conduit pipe of size 25mm dia (heavy duty) Ivory color ISI marked suitable for electrical wiring including junction box, tees and bends etc, complete all as specified and directed.
Material and labour for electrical round sheet PVC material used for covering junction boxes, fan mounting and other electrical opening on wall, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair MCB Protected socket (modular AC box) 3 Module with MCB SP of capacity 25 Amp and power socket for geyser, complete all as specified and directed by Engr - in - Charge.
M & L for rendering 15mm thick in cement mortar 1:6 on internal fair faces of brick/stone walls or on concrete surfaces, finished even and smooth with using using extra cement, complete all as specified and as directed.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of 2 mm thick wall care putty preparatory to distempering including preparation of surface, complete all as specified and as directed by Engr-in-Charge
Preparation of newly plastered wall surfaces and appling two coats of cement base paint over a coat of white wash, complete all as specified and as directed by Engr-in-Charge
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4.00mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
Taking down ceiling fan of any sweep, any size/make from existing position of any height by disconnecting electrical connections and transporting to workshop. Inspection of ceiling fan in presence of Engrs- in - charge/JE (or rep of department) after dismentling spares parts. Transporting ceiling fan back from work shop to site including hanging/ fixing and connecting up and testing etc complete all as required at site and directed by Engr - in - Charge.
M&L for complete repair and maintenance of unserviceable ceiling fan of 1200mm/1400mm sweep at work shop, incl dismantling complete the ceiling fan parts i.e. blades, fan rod, canopy, connection, inspecting serviceability of all the parts, re fixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, bracket, rubber bush, connecting wire, PVC connector, aluminium clamp for rod, bracket, bush rod, blade and greasing/oiling etc assembling, cleaning and testing of ceiling fan as directed. Note:- (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Writing of MES Nos and painting of ceiling fan shall be measured & paid separately uner relevant item of Sch 'A'. (iv) A register will be maintained by the contractor for record of repair duly signed by JE and Engr-in-Charge & contractor. (v) Cost of minor part i.e. Cotterr pin, PVC connector, screws shall deemed to be included in the quoted rate.
Removing of old burnt winding wiring any type, cleaning stator complete for burnt wiring, carbon residue and rewinding of stator winding of any type/any make fan/ any stator design ceiling fan of 1200mm sweep with superior quality super enameled winding copper wire of existing specification, gauge and weight with superior quality insulation for satisfactory functioning fan in presence of JE/Engr-In-Charge complete all as directed by Engr-in-Charge
Supply only ball bearing of existing number suitable for ceiling fan 1200/ 1400mm sweep of approved makes including necessary greasing complete all as specified and directed. Make : NBC/ SKF/FAG
Supply only gun metal bush of existing size suitable for 1200/ 1400mm sweep ceiling fan, complete all as specified and directed.
Supply only capacitor 2.5 MFD including necessary connection, complete all as specified and directed. MAKE- USHA/Havells/Epcos/BAJAJ
Supply only down rod 15mm bore, 300mm long fixed one end with mild steel U clamp, nut, lockable bolt, rubber reel, lock pin and other end having threaded/ drilled hole end, suitable nut, bolt, split pin and check nut or aluminium clamp duly white painted suitable for all size and makes of ceiling fan, complete all as specified and directed.
All as per Srl Item No. 75 here-in-before but 450mm long.
Supply only blade of 1200mm sweep of ceiling fan, complete all as specified and directed.
Supply and fixed in repair stepped type electronic fan regulator flush type, complete all as specified and directed.
M&L for painting one coat of synthetic enamel paint (white) using spray machine painting on the surface of ceiling fan of 1200/ 1400mm sweep (Including blade) complete after preparation of surface i.e cleaning, washing of surfaces filling cavities with filler, cleaning dust and writing MES No., complete all as specified and directed by Engr-in-Charge.
Supply only U clamp/ brass bracket assy with rubber reel with nuts, bolt 10mm dia, lock/ split pin, washer suitable for ceiling fan clamp, complete all as specified and directed.
Supply only top and bottom canopy of plastic with steel screw suitable for rod for fan of 1200/ 1400mm sweep, complete all as specified and directed.
Taking down carefully exhaust fan of any sweep, any size/make from existing position of any height by disconnecting electric connections and transporting to workshop. Inspection of ceiling fan in presence of Engr- in - charge/JE (or rep of department) after dismentling spares parts. Transporting exhaust fan back from work shop to site including hanging/ fixing and connecting up etc, complete all as required at site and directed by Engr - in - Charge.
M&L for complete Repair and maintenance of unserviceable exhaust fan of any sweep at work shop, including dismantling complete the parts i.e. blades, fan cover, connection, inspecting serviceability of all the parts, refixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, connecting wire, PVC connector and greasing/oiling etc assembling, cleaning and testing of exhaust fan as directed by Engr-In-Charge. Note: (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Painting of exhaust fan shall be measured & paid separately uner relevant item of Sch 'A'. (iv) A register will be maintained by the contractor for record of repair duly signed by JE and Engr-in-Charge & contractor. (v) Cost of minor part i.e. Cotterr pin, PVC connector, screws shall deemed to be included in the quoted rate.
M&L for rewinding stator of exhaust fan 450mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
M&L for rewinding stator of exhaust fan 300mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
M&L for rewinding stator of exhaust fan 250/200mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
Supply and fixing of motor of plastic body exhaust fan of 200/250mm sweep as per existing sample, complete all as specified and directed by Engr-in-Charge.
Supply only ball bearing of exhaust fan suitable for 200 to 450mm sweep as per existing ball bearing including necessary greasing, complete all as specified and directed. Make:-NBC/SKF/FAG/Norma
Supply only mounting legs with rubber suitable for any type of exhaust fan, complete all as specified and directed.
Supply only of steel blade suitable for exhuast fan upto 300mm sweep, complete all as specified and directed.
Supply only of plastic blade complete set suitable for exhuast fan upto 300mm sweep, complete all as specified and directed.
Supply only of plastic body suitable for exhaust fan of size 300mm sweep and making necessary connection, complete all as specified and directed by Engr - in - Charge.
Supply & fix exhaust fan louvers suitable upto 300mm sweep exhuast fan complete with necessary nut, bolt iron work, complete all as specified and directed by Engr - in - Charge.
Supply & fix XPM Jaali at wall opening for exhaust fan of size 300mm/380mm /450mm sweep of suitable size, complete all as specified and directed by Engr - in - Charge.
Supply only capacitor 1/1.8 MFD 50 Hz suitable for Exhaust fan, complete all as specified and directed by Engr - in - Charge. MAKE- USHA/Havells/Epcos/BAJAJ
M&L for painting one coat of synthetic enamel paint (black) using spray machine painting on the surface of exhaust fan of size upto 450mm sweep (including louvers and other parts of exhaust fan) complete after preparation of surface i.e cleaning, washing of surfaces filling cavities with filler, cleaning dust and dirt, complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated copper (Flexible) conductor PVC sheathed three core 0.50 sqmm for making connections between ceiling rose and winding, complete all as specified and directed.
Taking down water storage heater (Geyser) of 25/35/50 liters capacity from electric socket and disconnecting from PVC connection, water supply and screw down kept aside for reuse at same / different location after cleaning of geyser tank, refixing the same duly grouting nuts, bolts washers and connecting to existing water connection complete, all as specified and as directed by Engineer-in-Charge. complete all as specified. Note :- Unserviceable part shall be measured and replaced separately under respective items.
Supply and replacement of heating elements 2KW 230V ISI marked round base suitable for water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
Supply and replacement of heating elements 2KW 230V ISI marked triangular base suitable for water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
Supply and replacement of heating elements 1.5KW 230V ISI marked triangular base suitable for water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
Supply and replacement of heating elements 3KW 230V ISI marked suitable for instant water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
S&F in repair heating element (as per sample exist in ground of make recold/venus geyser) inbulid with round base and having 6 hole for fixing and provision of thermostat of 25 ltrs capacity geyser including necessary studs, screws and rubber gasket/washers, complete all as specified and directed.
S&F in repair for thermostat switch of geyser 230V, (adjustable range bewteen 0 degree to 90 degree centigrade temp range), ISI marked as per existing thermostat suitable for hot water storage heater 25/ 35 / 50 Ltr, complete all as specified and as directed.
S&F in repair for capillary thermostat switch (as per sample exist in ground of make recold/venus geyser) of geyser 230V, (adjustable range bewteen 0 degree to 90 degree centigrade temp range), ISI marked as per existing thermostat suitable for hot water storage heater 25/ 35 / 50 Ltr, complete all as specified and as directed.
S&F in repair for defective steel inner tank of 25 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 6 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for defective steel inner tank of 25 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 9 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair defective steel inner tank of 35 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 6 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair defective steel inner tank of 35 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 9 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair best quality PVC pipe hot and cold water for geyser with adopter both end of size 10mm dia and 600mm length (ISI marked) suitable for geyser, complete all as specified and as directed.
S&F in repair Air release valve 15mm dia, ISI marked for geyser of cap 25/ 35/ 50 Ltr, complete all as specified and as directed.
S&F in repair non return valve 15 mm dia, ISI marked for geyser of cap 25/ 35/ 50 Ltr, complete all as specified and as directed.
S&F in repair fusiable plug of brass 15mm bore, ISI marked for geyser of cap 25/35/50 Ltr, complete all as specified and as directed.
S&F in repair for indicating lamp (green or red), 230V, flush type, suitable for water heater including taking down old unserviceable, complete all as specified and as directed.
S&F in repair siphon assembly made out of brass of 25 /35 ltrs (9 hole) capacity geyser including necessary studs, screws and rubber gasket/washers, complete all as specified and as directed.
S&F in repair siphon assembly made out of brass of 25 /35 ltrs (6 hole) capacity geyser including necessary studs, screws and rubber gasket/washers, complete all as specified and as directed.
Replacement of insulation material (Glass Wool, 25mm thick) for geysers 25-50 ltrs capacity, complete all as specified and as directed.
Repair to geysers inner water tank of 25 to 50 ltrs capacity in gas welding / brazing for water tightness, complete all as specified and directed by Engr - in - Charge.
Supply & Fix PVC cable 3 core 1.5 Sqmm flexible stranded, complete all as specified and as directed.
Replacement of old unserviceable anchor bolt 12mm x 100mm long, complete all as specifed and directed. (Note:- Anchor bolt shall be grouted with hammer drill only).
M&L for painting of outer body of geyser with two coats of synthetic enamel paint (white colour) by using spray gun, complete all as specified and directed by Engr - in - Charge.
Taking down wall mounted fan of any sweep, any size/make from existing position of any height by disconnecting elect connections and transporting to workshop. Inspection of ceiling fan in presence of JE/ Engr-In-Charge (or rep of department) after dismentling spares parts. Transporting exhaust fan back from work shop to store yard including hanging/ fixing and connecting up and testing etc, complete all as required at site and directed by Engr - in - Charge.
M&L for complete Repair and maintenance of unserviceable wall mounted fan of any sweep at work shop, incl dismantling complete the parts i.e. blades, fan cover, connection, inspecting serviceability of all the parts, refixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, connecting wire, PVC connector and greasing/oiling etc assembling, cleaning and testing of exhaust fan as directed by Engr-In-Charge. Note:- (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Painting of wall mounted fan shall be measured & paid separately uner relevant item of Sch 'A'. (iv) A register will be maintained by the contractor for record of repair duly signed by JE and Engr-in-Charge & contractor. (v) Cost of minor part i.e. Cotterr pin, PVC connector, screws shall be deemed to included in the cost of quoted rate.
M&L for rewinding stator of wall mounted fan 300mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
Supply only ball bearing of wall mounted fan suitable for 300mm sweep as per existing ball bearing including necessary greasing, complete all as specified and directed. Make : NBC/ SKF/ Norma/ FAG
Supply and fix capacitor of wall mounted fan as per exisiting make and model, complete all as specified and directed.
Single pole and neutral sheet metal enclosure with a two pin and earth plug top and socket complete with one single pole MCB 20 Amps, fixed in repair, complete all as specified and directed.
Supply and fix Plug top 3 Pin type of rating 6 Amp, 230 volts, complete all as specified and directed.
Supply and fix Plug top 3 Pin type of rating 16 Amp, 230 volts, complete all as specified and directed.
Supply and fix in replacement of plastic blade complete set suitable for wall mounted fan upto 300mm sweep, complete all as specified and directed.
M&L for GI tubing heavy grade 40mm dia pipe by making holes in wall, fixing of pipe and making disturbed surfaces good as existing for hanging of ceiling fan including all type of necessary attachements like angle iron, flat iron, nuts and bolts etc. required for hanging of ceiling fan all as required at site and as directed by Enge-In-Charge. Note:- (i) The length of the GI pipe shall be as per exisiting (room) length exc 3m but n.exc 4m. (ii) Taking down ceiling fan cleaning and refixing same and making electric connection with fan after fixing of pipe include in quoted rates.
M&L for fixing of ceiling fan with the help of anchor hook in ceiling including fan hanging junction box and making electric connection with fan, complete all as specified and as directed by Enge-In-Charge. Note:- Only fixing of old ceiling fan considered in item.
M&L for fixing of exhaust fan by making hole in stone/brick wall, fixing the exhaust fan with suitable arrangement, finishing the disturbed wall surface and connecting electrically, complete all as required at site and as directed by Enge-In-Charge. Note:- Only fixing of old exhaust fan considered in item.
M&L for fixing of exhaust fan in existing opening with the help of ply board having thickness 10mm and making electrical connection, complete all as required at site and as directed by Enge-In-Charge. Note:- Only fixing of old exhaust fan considered in item.
Kulbir Singh Govt. Contractor (BID ID -3098978)
Dhani Builders (BID ID -3099174)
ess are electricals and electronic (BID ID -3099358)
M/S PUSHPINDER ENGINEERS (BID ID -3095891)
S K MAHAJAN (BID ID -3099254)
M/S MALHI CONSTRUCTIONS (BID ID -3099376)
Eshaan Construction Co. (BID ID -3099057)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .