Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC Accepted. | |
| 2 | L2₹9.7 L+₹87,558.50 (9.94%)Rejected-Finance | L2 | Rejected-Finance other than lowest. |
Tender Value
₹10.1 L
EMD Value
₹20,200
Closing Date
5 Jun 2020, 6:00 pmClosed
GE Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana 141001
Special repair to single offrs accn bldg No. T-245 at Dholewal Mil Complex under GE Ludhiana.
2020_MES_341862_1
GE/LDH-06/2020-21
Open Tender
Civil Works
Item Rate
120 days
Dholewal under GE Ludhiana
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,200
Yes
22 Aug 2020
30 Apr 2020
6 Jun 2020
30 Apr 2020
5 Jun 2020
8 May 2020
30 Apr 2020 - 7 May 2020
Amount
Sch 'A' Sec-I
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete as in any description and in any position complete all as specified and directed by Engineer-in-Charge.
M&L, reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in chajjas complete all asspecified & directed by Engineer-in-charge.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhanges similar items for rough finished surface all as specified & directed by Engineer-in- charge
Use and waste of form work to edges of concrete floor and roofs and similar works exc 5 cm but not exc 10 cm wide for rough finished surface all as specified & directed by Engineer-in- charge
M&L, TMT bars 10mm dia and over cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified & directed by Engineer-in- charge.
Dismantling of stone slabs and tiles of any description or thichness in floors aprons etc laid bedded and pointed in any mortar complete all as specified & directed by Engineer-in- charge.
M&L, Granite slab 20 mm thick (table rubbed and polished) as in in steps, jambs,pillars, window-cill, cooking platform over and including 20mm thick bedding layer in cement mortar (1:4) in and pointed with white or colour cement (1:2) using marble dust with admixture to match the shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L, vitrified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tile n. exc. 0.36 sqm laid in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
Ditto as items No 10 above but as in skirting over rendering 10mm thick in cement mortor 1:4 .
M&L, non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.11 sqm but n exc 0.18sqm laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L, glazed ceramic coloured tiles 450mm x 350mm x 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L, 25mm thick cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floors finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L, 50mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge.
M&L, for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per item No.17 above but except bricks. (Old serviceable bricks retrieved from demolition of brick work shall be re-used after cleaning).
Taking down cement plaster of any description on brick or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified & directed by Engineer-in-charge
M&L, rendering 15mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge.
M&L, rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge
M&L, cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof kerbs or mud stops, sides of ruonded or chamfered on edges of sunken floor complete all as specified & directed by Engineer-in- charge.
Complete removal of existing treatment and applying two coat of exterior emulsion paint any tint (Apex) on external surfaces of walls , parapet , sides and tops of sunshade etc over one coat of primer with fibre brushes complete all as specified & directed by Engineer-in- charge.
Complete removal of existing treatment on old plastered surfaces of walls applying two coats of distemper oil emulsion over 3mm thick wall care putty complete all as specified & directed by Engineer-in- charge.
M&L, preparing newly plastered or pointed surface of wall and applying two coats of distemper oil emulsion over 3mm thick wall care putty complete all asspecified & directed by Engineer-in-charge.
M&L, applying two coat of exterior emulsion paint any tint (Apex) on external surfaces of walls parapet , sides and tops of sunshade etc over one coat of primer with fibre brushes complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50sqm but not exceeding 4.00sqm each and removing from site all as specified & directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50sqm each and removing from site all as specified & directed by Engineer-in- charge.
S&F, steel windows/ ventilator with side hung shutters incl box type hinge . with glazing bars and steel peg stay . each window shutter is to be fitted with 1 steel handle 100 mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat complete all as specified and directed by Engineer-in-Charge
S&F, steel windows/ ventilator with side hung shutters incl box type hinge . without glazing bars and steel peg stay . each window shutter is to be fitted with 1 steel handle 100 mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat complete all as specified and directed by Engineer-in-Charge
Supply & fixing, steel windows or ventilator fixed type with fixing lugs and glazing bars etc. duly treated with one shop coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Supply & fixing, galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanused wire staples all as specified &directed by Engineer-in- charge.
M&L, mild steel work conforming to Fe-410 or Fe-310 quality-A as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks, door chowkats and similar works complete all as specified & directed by Engineer-in- charge.
Supplying factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. sizes of members as specified in clause 8.24 (a) of MES Schedule (Part-I), and fitted to chowkhats complete all as specified & directed by Engineer-in- charge.
Supply and fixing pressed steel frame size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. duly treated with one shop coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing pressed steel frame size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. duly treated with one shop coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L, preparing steel and iron surfaces (new) of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
M&L, cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed plates, coping, water trough, filling of chowkhats, roof kerbs or mud stops rounded or chamferred on edges complete all asspecified & directed by Engineer-in-charge.
S&F, aluminium handles anodised cast type 125mm long all as specified & directed by Engineer-in-charge.
Supply and fixing, aluminium anodised barrel tower bolt of extruded section 150mm long all as specified & directed by Engineer-in- charge.
Supply and fixing, 250mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified & directed by Engineer-in-charge.
Supply & fixing, 35mm thick factory made plain framed panelled shutters (any no of panels) of 2nd class hard wood with lock rail and panel inserts of 9mm thick BWP commercial ply. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified & directed.
Supply & fixing, sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge.
Supply & fixing, helical door spring mild steel 300mm ordinary rat tail rod pattern mild steel frame including roller and roller plate and welding to frame as required complete complete all as specified and directed by Engineer-in-Charge.
M&L, preparing wooden or wood based surfaces (new) of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Taking down steel water tubes of size 15mm bore and connection including cleaning for refixing or removal to store complete, all as specified & directed by Engineer-in-charge.
Taking down steel water tubes of size 20mm bore and connection including cleaning for refixing or removal to store complete, all as specified & directed by Engineer-in-charge.
Supply & fixing, steel water tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors/ concealed in walls pe complete, all as specified & directed by Engineer-in-charge.
Supply & fixing, steel water tubes of size 20mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors/ concealed in walls pe complete, all as specified & directed by Engineer-in-charge.
Re-fixing old steel water tubes of size 15mm bore in new/ old location using new fittings fixed complete to walls and ceiling or laid in floors/ concealed in walls complete, all as specified & directed by Engineer-in-charge.
Re-fixing old steel water tubes of size 20mm bore in new/ old location using new fittings fixed complete to walls and ceiling or laid in floors/ concealed in walls complete, all as specified & directed by Engineer-in-charge.
Dismantling PVC water storage tank of capacity exc 500 litre but n. exc 1000 litre and removing from site all as specified & directed by Engineer-in- charge.
Supply & fixing, rotational moulded polyethylene water storage tank of capacity 1000 litres (cylindrical vertical double layered with closed top) hoisted and fixed in position as per specified SSR part-I complete, all as specified & directed by Engineer-in-charge.
Supply & fixing, ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule 20mm bore all as specified & directed by Engineer-in-charge.
Supply & fixing in repair stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or brass ferrule 20mm bore complete all as specified & directed by Engineer-in-charge.
S&F in replacement vitreous china wash down water closet pan (pedestal pattern) white with trap including connection to existing out joint pipe, flushing pipe or cistern, antisyphonage pipe, including making good to floor etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair plastic water closet seat white closed pattern with flat botom and cover mild steel chromium plated or aluminium plated or aluminished hinging device complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair vitreous china wash basin, white, flat back of size 550mm x 480mm fixed on brackets including 32mm dia CP waste coupling complete all as specified and directed by Engineer-in-Charge. (make: Cera cat part No. S2040115 and S2090111 or Equivalent Neycer / Jaguar, / Perryware
M&L, 75mm dia cast iron floor trap with grating including jointing to waste pipe with run lead joint and embedded in cement concrete (1:2:4) type B-1 using graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, cast copper alloy chromium plated fancy type single lever basin mixer complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 15mm bore two way bib tap with flange chromium plated cast copper alloy, fancy type with crutch or butterfly handle screwed down for iron pipe for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F, CP Jet spray suitable for europian western commode (EWC) including PVC Connection 15mm size with PTMT nuts and washer of length 900mm complete all as specified and directed by Engineer-in-Charge.
S&F, soap dish fixed to walls with chromium plated brass screw complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair stop valve/angle valve cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repairs chromium plated stop valve concealed type with long shank, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for unions suitable for size 15mm bore complete, all as specified & directed by Engineer-in-charge.
Supply & fixing, PVC connection 15mm size 600mm long with PTMT nuts complete all as specified & directed by Engineer-in-Charge.
S&F, toilet paper holder of CP fixed to wall with chromium plated brass screw complete all as specified & directed by Engineer-in-Charge.
Supply & fixing in repair brass chromium plated tubular towel rail , 20mm dia D-type, 60cm long between flanges all as specified & directed by Engineer-in- charge.
Supply & fixing in repair brass chromium plated tubular towel rack , all as specified & directed by Engineer-in- charge.
S&F in repair brass CP wall mixer with bend pipe for overhead screwed down for 15mm iron pipe all as specified & directed by Engineer-in- charge
S&F in repair PVC bathroom cabinet mirror size 350mm x 450mm all as specified & directed by Engineer-in- charge
Supply and fixing in repair chromium plated shower rose 125mm size with or without swivel joints including fixing to 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F, 5.5mm thick looking mirror including frame of size 1200x600mm complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets any thickness including cover fillets complete all as specified and directed by Engineer-in-Charge.
S&F, GI frame work 605x605mm grid for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screw 450mm centre to centre / intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section ( not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified & directed by Engineer-in- charge.
S&F, hangers of 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of 40mm x 3mm GI flat 60mm long and expansion hold fastners 12.5mm dia, 40mm long complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 4mm thick E-board; multipurpose, decorative type for false ceiling all as specified & directed by Engineer-in- charge.Make: Everest/ Charminar/ Lake & Hill.
Taking down curtain rod along with wooden pallmate laid on wall complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, curtain rod made out of 25mm dia (outer dia) pipe having thickness 0.63mm,PVC coated and colour / Pattern over all dia 28 to 29mm complete all as specified and directed by Engineer-in-Charge.
Supply & fixing, plastic finial of 28 to 29mm bore decorated type of any colour /Patern best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified and directed by Engineer-in-Charge
Supply & fixing, mild steel prepainting bracket to hold the curtain rod and fixed to wall (concrete /brick masonary) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the distrubed surfaces complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
M&L, cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof kerbs or mud stops, ruonded or chamfered on edges complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 75mm bore cast iron soil, waste and vent pipe in any length with or without ears with cement joints laid in trenches or in floor as specified & directed by Engineer-in-charge.
S&F, 75mm bore cast iron cowls complete all as specified and directed by Engineer-in-Charge.
S&F, glass shelf assembly with stainless steel frame corner glass shelf etc complete all as specified and directed by Engineer-in-Charge.
M&L, hard core of broken stone boulders of gauge n. exc. 63mm; deposited, spread and levelled in layers n. exc. 15cm thick watered and rammed to true surface complete all as specified and directed by Engineer-in-Charge.
M&L, Endura ceramic concrete tiles 30cm x 30cm x 10mm thick in floors set, jointed & pointed in neat cement slurry using grey cement and pigment laid over and including 20mm thick screed bed in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L, reinforced cement concrete cast-in-situ (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth coarse, bed plates, coping, kerbs for road, water trough and like incl rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description in any position complete all as specified & directed by Engineer-in- charge.
Dismantling timber scantling 40 sqcm and over in section in any position all as specified & directed by Engineer-in- charge.
M & L, roof trusses framed, framed purlins, crane gantries, rails and fastenings (beams, tee, angle, channel or flat sections) including distance pieces conforming to Fe 410-W Gde E-250 complete all as specified & directed by Engineer-in- charge.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof covering all as specified & directed by Engineer-in- charge.
S&F, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified & directed by Engineer-in- charge.
S&F, pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified & directed by Engineer-in- charge.
Excavation in trenches n. exc 1.5 m wide for foundations, pipe line etc. and not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge.
M&L, pre-cast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole cover and set in cement mortar (1:4) including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up 150mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar all as specified & directed by Engineer-in- charge.
M&L, cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in bed to 150mm bore SGSW drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified & directed by Engineer-in- charge
M&L, 150mm bore internal dia salt glazed stone ware drain pipe laid in trenches including jointing & testing complete with collars complete all as specified & directed by Engineer-in- charge
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed by Engineer-in-charge.
Removal of surplus spoil to a distance n.exc 50 m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
Supply & fixing, in repair galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanused wire staples all as specified &directed by Engineer-in- charge.
S&F in repair stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 915mmx460mm with bowl size 410mm x 330mm x160mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair Pre-laminated (both side) particle board 18/19mm thick with decorative choice laminations, interior grade fixed with screws to timber frame complete all as specified and directed by Engineer-in-Charge.
Sch 'A' Sec-II
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good disturbed surfaces of walls and floors etc to match with the existing complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan, any sweep and size, sealing cable, dismantling fan blades, re-assembling the ceiling fan and re-fixing in original position and making connections using new PVC insulated copper conductor cable of size 23/.0076 sqmm from ceiling rose to connector/ fan including supply and replacement of split pins complete all as specified and directed by Engineer-in-Charge.
M&L, Painting to ceiling fan of any make/ model/ sweep by removing old paint and filling cavaties with filler and applying one coat of super enamelled paint of colour as per existing using spray gun and writing MES numbers with black paint complete all as specified and directed by Engineer-in-Charge.
M&L point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including concealed heavy duty PVC conduit including cutting chases in walls and making good the disturbed surface with all jointing accessories including provision of 3mm thick bakelite sheet top cover on new sunken boxes fixed with new screws & washers including 1.5 Sqmm FRLS, PVC insulated unsheathed stranded copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point/ bell point controlled by one switch or one fan point controlled by one switch through regulator complete all as specified and directed by Engineer-in-Charge.
All as per item No.109 above but for one 5 pin 5/6 Amps socket outlet on independent board.
All as described in Srl item No.109 above but for one 5 pin 5/6 Amps socket outlet on same board with other switch.
All as per item No. 109 here-in-before but with FRLS cable of cross sectional area 2.5 Sqmm for one socket outlet 15/16 Amps independent including 2.5 Sqmm FRLS, PVC insulated unsheathed solid conductor wire as earth continuity to common earth all as specified & directed.
S&F in replacement 18 Watt LED decorative ultra slim linear LED light fittings fixture with co extruded polycarbonate body, environmental enegy efficient including connection from celing rose to connector complete with all acessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.Make Crompton Greaves cat part No LCTL-18-CDL for LED batten or LT5RT1-18-CDL for LED tube or equivalent Bajaj / Philliips / Havells
S&F in replacement 10 Watt 600 mm T5 TL LED decorative ultra slim linear LED light fittings fixture with co extruded polycarbonate body, environmental enegy efficient including connection from celing rose to connector complete with all acessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.Make Crompton Greaves cat part No LCTL-9-CDL for LED batten or LT5RT1-9-CDL for LED tube or equivalent Bajaj / Philliips / Havells
M&L, submain wiring with three single core FRLS PVC insulated unsheathed multistranded copper conductor cables of size 6 Sqmm FRLS PVC insulated copper conductor one run green insulation copper conductor cable as earth continuity drawn in and including medium grade PVC rigid non metelic conduit not less than 25mm dia with necessary conduit fittings concaeled in wall including cutting chases and making good the disturbed surface to match the existing surface including taking down existing submain wiring complete all as specified and directed by Engineer-in- charge. Make: Havells / Anchor / Finolex / Plaza Note: 2 runs of 6 sqmm , 1 run of 6 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length.
M&L, submain wiring with three single core FRLS PVC insulated unsheathed multistranded copper conductor cables of size 4 Sqmm FRLS PVC insulated copper conductor one run green insulation copper conductor cable as earth continuity drawn in and including medium grade PVC rigid non metelic conduit not less than 25mm dia with necessary conduit fittings concaeled in wall including cutting chases and making good the disturbed surface to match the existing surface including taking down existing submain wiring complete all as specified and directed by Engineer-in- charge. Make: Havells / Anchor / Finolex / Plaza Note: 2 runs of 4 sqmm , 1 run of 4 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length.
Supply & fixing in replacement factory made sheet metal distribution boards, TPN, 4 way, double door; protection class IP-43 suitable for housing MCB/ isolators, conforming to IS-13032, IS-8623, BS-5484 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply and making niche, replacement to match with existing surface etc complete all as specified and directed by Engineer-in-Charge. Make: Legrand/Havells/L&T/Hagger
Supply & fixing in replacement MCB TPN 415 volt, 40 Amp with rupturing capacity 16 KA, 50 Hz complete all as specified and directed by Engineer-in-Charge.Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply & fixing in replacement MCB TP (triple pole) 415 volt, 6-32 Amp with rupturing capacity 16 KA complete all as specified and directed by Engineer-in-Charge.Make: Standard /Havells/ Indo Asian / BCH / C&S
S&F in replacement factory made sheet metal enclosure for distribution boards, SPN, 8 way; double door with 200 Amps rated copper bus bar suitable for housing MCBs and isolator and working on 240 volts AC supply including making good to match with existing surfaces complete all as specified & directed by Engineer-in- charge.Make: Hagger/L&T/Legrand / Indo Asian
Supply & fixing in replacement MCB SPN 240 volt, 6-32 Amp, 50 HZ, 10 KA rupturing capacity 'C' series all as specified & directed by Engineer-in- charge. Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply & fixing in replacement MCB single pole 240 volt, 6 to 32 Amp, 50 HZ, 10 KA rupturing capacity 'C' series all as specified & directed by Engineer-in- charge. Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply and fixing, ceiling rose surface bakelite 65x 50mm with two or three terminal, polycarbonate /pvc/ isolated body all as specified and directed by engineer in charge.
Supply and fixing, switch piano flush type single pole one way 5 Amps, 230 volts all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing, socket outlet 3 pin,5 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing, switch socket combination two in one 5 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing, switch socket combination two in one 3 pin 16 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply & fixing, speed regulator for ceiling fan 1200mm/ 1400mm flush stapped type 230 volts complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 3.5 core laid in trenches/ ducts/ along poles/ through pipes including taking out existing cable complete all as specified & directed by Engineer-in- charge. Make: Havells / Polycab / CCI
Supply and fixing in replacement LED security light fitting LED 30 watt Epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 protection including with bracket bend to shape/size require and fixing with two nos MS clamps for suitable size complete all as specified and directed by Engineer-in- charge. Make: Havells /CG / Phillips
Excavation in trenches soft / loose soil n. exc 1.5 metre wide for taking out/ laying unseviceable of LT cable, pipe line etc. and not exceeding 1.5 metre deep and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed by Engineer-in-charge.
Removal of excavated surplus spoil to a distance n.exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed by Engineer-in-charge.
M & L, sand cushioning for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge. Note: Thickness of 18 cm after punning shall be considered for payment.
M & L brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed by Engineer-in-Charge
M&L, Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end connecions to main switch board and protected by galvanised iron light grade 40mm dia pipe, 20mm dia pipe for water with funnel, wire mesh, PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover (1:2:4) type B-1 using 20mm graded stone aggregate and 8mm dia TMT bar @ 10cm c/c both way including MS frame using MS angle of size 45mmx4mmx5mm complete all as specified and shown in electrical plate No-3 in MES Schedule (Part-I).Notes - (i) Outer edge of earth pit will be 1.5 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position.(Earth wire and protection pipe upto 7.50m length is included in the unit rate)
AGNIHOTRI CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .