Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹48.2 L+₹1.3 L (2.68%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹48.2 L+₹1.3 L (2.73%)Rejected-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹48.7 L+₹1.8 L (3.79%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹48.7 L+₹1.8 L (3.85%)Rejected-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
11 May 2021, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
PROVN OF POL STORE, REPLACEMENT OF GI PIPE WITH PPR PIPE AND SPL REP/REPLACEMENT OF LT PANEL WITH POLYCARBONATE PANEL AT ICGS VADINAR UNDER GE (I) CG PORBANDAR
2021_MES_437784_1
8610
Open Tender
Civil Works
Item Rate
180 days
ICGS VADINAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹88,000
Yes
5 Jul 2021
22 Apr 2021
12 May 2021
22 Apr 2021
11 May 2021
6 May 2021
Amount
SCHEDULE 'A'
Surface excavation n exc 30cm deep and avarage 15cm deep and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in any type of Soil.
M&L for PCC 1:4:8 type D2 using 40mm graded stoe aggregate in fdn filling and mass concrete.
Formwork to sides of column footing/plinth beam etc, rough finished surfaces of concrete flat.
Formwork to sides of columns, rough finished surfaces of concrete square or rectangular.
Formwork to sides of beam/lintel bend and similar structure for flat rough finished surfaces.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping etc complete
M&L RCC 1:2;4, Type B-1 Nominal mix as in foundations, including rafts, footings, foundation beams; plinth beams; base for columns, etc.; basement slabs, unde-reamed piles and mass concrete.
M&L RCC 1:2;4, Type B-1 Nominal mix as in coloums, pillars, piers, posts and struts.
M&L RCC 1:2;4, Type B-1 Nominal mix as in beams, lintel band and gable beams.
M&L RCC 1:2;4, Type B-1 Nominal mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies ,canopies, deck slabs and in shelve and like all as specifed and as directed
M&L for CRS TMT steel bars 10 mm dia and above, as in reinforcement for concrete, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and as directed.
All as per item No (13) above but above 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed.
All as per item No (13) above but above 8mm dia and over upto and including 10mm dia as as in reinforcement for concrete, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and as directed.
M&L pre-cast cement concrete block masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10 cm in width and setting in CM 1:6 complete
M&L Damp proof course in cement concrete 1:2:4 type B-0, 40 mm thick including necessary form work with WPC as per manufacturer instruction by weight of cement.
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring.
M & L for PCC 1:2:4 type B0 (using 12.50mm graded stone aggregate) 40mm thick as in floors complete all as specified.
M&L Providing PCC 1:3:6 types C1 (using 20mm graded stone aggregate) 75mm thick as in plinth protection, finishing cement concrete surface even and smooth without using extra cement.
M&L rendering 10 mm thick on other than fair faces of brick work/pcc block masonry or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 5mm thick in CM 1:4 with using water proofing compound @ 2% of weight of cement content over 10mm thick in CM 1:6 on surfaces of block masonry even smooth without using extra cement complete all as specified. Note:- Waterproofing compound paid seperatly.
M&L rendering 5mm thick in CM 1:3 on fair faces of concerete surfaces of ceiling finished even and smooth without using extra cement complete all as specified.
Supply only integral water proofing compond
Material and labour for three coats of white wash on new plastered surface of wall incl necessary preperation.
As per Item No-26 above but on ceilings
M & L for applying two coats of Acrylic emulsion paint over a coat of primer including preparation of new plastered surfaces of wall complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point
M & L Framed work as in doors or ornamental gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for preparing of new steel surfaces and applying two coats of synthetic enamel paint over a coat of primer complete all as specified.
M&L for 40 mm thick precast RCC jallies type B0 , 1:2:4 (12.5 mm graded stone aggregate) (measured solid) , including all mould- ings etc complete all as specifed and as directed.
M/L cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 100 mm thick as in foundation complete all as specified.
M&L for 20mm thick Sand filling under floors or in foundations including watering and consolidation
Machine pressed precast cement concrete inter locking paver blocks and any shape and size with grey cement and pigment conforming to IS: 15658-2006, 80 mm thickness M-40 Grade
Supply and fix in replacement 3- layer PP-R Polypropylene random copolymer)pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for water supply all PP-R plain & brass threaded polypropylene random including fittings laid in trenches for following pipes. Make : SFMC/Vectus a) 110 mm outer dia
b) 63 mm outer dia
c) 50 mm outer dia
d) 40 mm outer dia
Supply and fix in replacement 3- layer PP-R Polypropylene random copolymer)pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for water supply all PP-R plain & brass threaded polypropylene random including fittings laid in wall/ceiling/floor for the following pipe Make : SFMC/Vectus a) 32 mm outer dia
b) 25 mm outer dia
c) 20 mm outer dia
Supply and fix in replacement PPR Gate valve (brass insert) for following :- Make : SFMC/Vectus a) 63 mm Outer dia
b) 32 mm outer dia
c) 50 mm outer dia
M & L in replacement for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Copper bus bar of suitable capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and out going with openable shutter both sides comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of shor circuit withstand Test report issued by CPRI in respect of LT Panel (b) Contractor shall submit the drawing for approval prior to place the order. Make of Panel : Hensel/Neptune Make of MCCB/MCB : Legrand/L&T a) Incoming - MCCB 160 Amp FP 36 KA - 01 No b) Outgoing - MCCB 100/63 Amp FP 36 KA- 04 Nos c) MCB 32 Amps 4 Pole - 04 Nos d) MCB 63 Amps 4 Pole - 04 Nos e) MCB 32 Amps 2 Pole - 04 Nos f) Digital panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm
M & L in replacementfor LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Copper bus bar of suitable capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and out going with openable shutter both sides comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of shor circuit withstand Test report issued by CPRI in respect of LT Panel (b) Contractor shall submit the drawing for approval prior to place the order. Make of Panel : Hensel/Neptune Make of MCCB/MCB : Legrand/L&T a) Incoming MCCB 250 Amps four pole with microprocessor based release, having breaking capacity 36 KA, ---01 No b) Outgoing MCCB 100/63 Amps four pole with microprocessor based release, having breaking capacity 25 KA, ---07 No. c) MCB 32 Amps 4 Pole - 02 Nos d) MCB 63 Amps 4 Pole - 04 Nos e) MCB 32 Amps 2 Pole - 04 Nos f) Digital panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm
M&L 300mm bore earthing, with 19mm dia and 3m long solid copper earth electrode, connected with earthing lead of size 20mm x 3mm copper strip, to the earth test point (upto 7.5m length) including excavation and earth work,with chemical compound, to reduce soil sensitivity and provision of PCC earth pit of size as shown in electrical plate no 03 includng provision of high quality earth pit cover made of polymer in lieu of CI cover indicated in the electrical plate, all as specified and as directed by Engineer-in-Charge. Note: The Compound (earth enhance gel) to reduce soil sensitivity should be suitable for the prevailing soil, IR value should be less than 2.0 ohms
M&L point wiring with FRLSH1.5 sqmm (nominal Area), PVC insulated multistranded , single core , unsheathed , copper conductor cables with colour code as per IS specifications drawn through Steel ERW Conduit of suitable size with all fittings and accessories of Steel ERW Conduit (like Tee, bend,junctions clips,screws etc) complete fixed to walls/ceiling etc. with including 1.5 sqmm (nominal area) PVC insulated , unsheathed, stranded , single core, copper cable green in colour as in earth continuity wire connecting to common earth point for the following. Make of Cable : KEI/Anchor/RR Kabel a) One light point /fan point controlled by one switch with cable 1.5 Sqmm
M&L point wiring with FRLSH 2.5 sqmm (nominal Area), PVC insulated multistranded , single core , unsheathed , copper conductor cables with colour code as per IS specifications drawn through Steel ERW Conduit of 25mm dia with all fittings and accessories of Steel ERW Conduit (like Tee, bend,junctions clips,screws etc) complete fixed to walls/ceiling etc. with including 2.5 sqmm (nominal area) PVC insulated , unsheathed, stranded , single core, copper cable green in colour as in earth continuity wire connecting to common earth point for one 3 pin socket outlet 16 Amps independent Board complete all as specified. Make of Cable : KEI/Anchor/RR Kabel
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Make: Sudhir/ Shyam switch gear
M&L for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. Make: Sudhir/ Shyam switch gear
M&L for Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. Make: Sudhir/ Shyam switch gear
M&L Sub main wiring with two runs of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I including conduit accessories like bends, tees, junction boxes etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ Finolex/ RR Kable/ KEI
Supply and fix sheet metal enclosure for Single pole and neutral DBs when MCBs to be used 8,way 415 V double door with 200 Amps bus bar. Make:Legrand/Standard/Havells
S&F MCB single pole 240 Volts 5/6 to 30/32 amps. Make:Legrand/Standard/Havells
M&L for MCB Single pole & nutral 215 Volts 32 Amps Make:Legrand/Standard/Havells
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core. Make: Polycab/Havells/Gloster
Supply and Lay, 40 mm OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings all as speciifed and directed. Make : Gemini or its equivalent
BABUBHAI BHIMABHAI PANDAVADRA
Harsh Infrastructure
natwarsinghdipsingh
KRISHNA ENGINEERING
lord krishna construction company
SHREE CHAMUNDA ENTERPRISE
K K Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .