| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.3 L+₹4.4 L (24.6%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹22.7 L+₹4.8 L (26.5%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Rejected being |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)/AMB-18(P)/2020-21 DAY TO DAY MAINTENANCE OF E/M COMPLAINTS, REPAIR/REPLACMENT OF FITTINGS, FIXTURES AND OTHER MISC CONNECTED WORKS IN MD ACCN IN AREA - III AND IV SECTOR B OF AGE E/M (N) AMBALA CANTT
2020_MES_338803_2
GE(N)Amb-18(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹70,000
Yes
17 Aug 2020
26 Jun 2020
29 Jul 2020
26 Jun 2020
27 Jul 2020
13 Jul 2020
27 Jun 2020 - 12 Jul 2020
60 days
Amount
Supply & laying 1.5 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor through existing conduit/ casing & caping complete all as specified and directed including taking out of old Unserviceable/burnt out wire of any size, complete all as specified and as directed by Engr-in-charge. . Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB
Ditto as per item No 1.01 here in before but 2.5 sqmm, complete all as specified and as directed by Engr-in-charge.
Ditto as per item No 1.01 here in before but 4.0 sqmm, complete all as specified and as directed by Engr-in-charge.
Ditto as per item No 1.01 here in before but 6.0 sqmm, complete all as specified and as directed by Engr-in-charge.
M&L for rectifying the short circuit of internal wiring/ sub main wiring replacing the burnt wire with the rating of existing wire as required at site. Note:- 1. The complaint will be attended round the clock and the contractor will be penalized @ Rs 150 per hour when the complaint will not be attended within 2 hrs of issuing of the complaint. 2. Other details as per particular specifications and the rates quoted may be deemed to include the same.
M&L for rectifying the current leakage /electric shock of internal wiring/ sub main wiring ensuring that no leakage current passes Note:- 1. The complaint will be attended round the clock and the contractor will be penalized @ Rs 150 per hour when the complaint will not be attended within 2 hrs of issuing of the complaint. 2. Other details as per particular specifications and the rates quoted may be deemed to include the same.
Supply & Laying PVC insulated and PVC round sheathed, Copper conductor(flexible) industrial cable 3 core 2.5 sqmm 1100 volts confirming to IS: 694 cable including taking down old Unserviceable cable complete all as specified and as directed..
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core 6 Sqmm cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape or tape and overall PVC sheathed in service connection, including disconnecting and taking down old Unserviceable existing cable complete all as specified and as directed.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core 10 Sqmm cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape or tape and overall PVC sheathed in service connection, including disconnecting and taking down old Unserviceable existing cable complete all as specified and as directed.
Supply & Fix switch piano, flush type single pole, one way 5 Amp including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix bell push 6 Amp including removing Unserviceable items including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix socket 2/3 pin 6 Amp including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix switch piano flush type single pole, one way 15 A including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix socket 6 pin 5/15 Amp multi purpose 230V including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix Step fan regulator electronic socket type, flush type 230 volt including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix Step fan regulator electronic switch type, flush type 230 volt including removing Unserviceable items.
Supply & Fix in replacement of capacitor 2.5 mfd for ceiling fans of any descriptions including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix calling bell ding dong 230 V including removing Unserviceable items,complete all as specified and as directed by Engr-in-charge.
Supply & Fix mild sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-1) of 1969 of size 7"x4" including fixing arrangement with necessary cement work and removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fix mild sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-1) of 1969 of size 8"x10" including fixing arrangement with necessary cement work and removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply and fix ceiling rose surface type 2/3 terminal complete including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply and fix lamp holder, insulated body, with back plate for angular batten fittings complete all including taking down Unserviceable item. .
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down Unserviceable bulbs all as specified and as directed..
S&F LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all including taking down Unserviceable bulbs as specified and as directed.
Supply and fixing LED batten fitting 18-20 watt, 4 feet, including driver aluminium body cool/warm tube rod industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down Unserviceable light fitting of any type and capacity and removal complete all as specified and directed.
Supplying and fixing in replacement LED tube rod 18/20 watt 4 feet, aluminium body, cool/warm tube rod industrial model with high frequency power factor suitable for surface mounting batten fitting complete including disconnecting and taking down Unserviceable tube rod of any type all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement recess mounting LED 15/18 Watt circular down lighter/ COB panel with aluminium die cast housing, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with 3 core flexible copper conductor from ceiling rose to connector of the light, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed.
Supply and fix MCB SP 6-32 Amps, 240 volt,10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
Supply and fix MCB SPN 32/40 Amps, 240 volt,10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
Supply and fix MCB TPN 63 Amps 240 volt, 10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
S&F MCCB 3 pole , 63 Amp, 415 Volts 16 KA ,fixed type including fixing arrangement, including removing old Unserviceable MCCB complete all as specified and as directed by Engr-in-charge.
S&F MCCB 4 pole , 100 Amp, 415 Volts 25 KA ,fixed type including fixing arrangement, including removing old Unserviceable MCCB complete all as specified and as directed by Engr-in-charge.
S&F MCCB 4 pole , 200 Amp, 415 Volts 35 KA ,fixed type including fixing arrangement, including removing old Unserviceable MCCB complete all as specified
Supply and fix RCBO 32 Amps 2 Pole two module 100 mA (HI immunity) sensitivity 230 volts 50 Hz ISI marked, including removing old Unserviceable RCBO complete all as specified and as directed by Engr-in-charge.
Supply and fix RCBO 40 Amps 2 Module 300 mA sensitivity 230 volts 50 Hz ISI marked,including removing old Unserviceable RCBO complete all as specified and as directed by Engr-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp including removing old Unserviceable enclosurecomplete all as specified and as directed by Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with acrylic double door,IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old Unserviceable enclosure complete all as specified and as directed by Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfacesincluding removing old Unserviceable enclosure complete all as specified and as directed by Engr-in-charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) with MCCB 125 Amp TPN for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old Unserviceable enclosure complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED flat panel 2' x 2' size surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , warm/cool white with provision of PVC flexible copper conductor cable to light fitting, including disconnecting and taking down existing light fitting and removing old Unserviceablefitting complete all as specified and as directed by Engr-in-charge.
S & F LED Bollard 8-10 W, IP-65 luminaire made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply , complete with all accessories internally pre wired including connecting with flexible copper conductor from Electric Supply Source to connector of the light including PCC 1:3::6 of size 400x400x400 mm, including disconnecting and taking down existing old Unserviceable fitting and removing complete all as specified and as directed by Engr-in-charge.
S & F LED post top luminaire 30W IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with fitting and including fitting & provision of 3 core PVC flexible copper conductor from Electric Supply Source to connector of the light, including disconnecting and taking down existing light fitting and removing old Unserviceable fitting complete all as specified and as directed by Engr-in-charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and making electrical connection, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and directed.
Taking down ceiling/exhaust/wall mounted/pedestal fans of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections and deposit at fan store of AGE EM north for issuing of fan to contractor for repair, and collecting the fan after repair hanging the same at location all as specified and as directed
M&L for opening the stator & rotor of the 1200mm sweep ceiling fan cutting the existing worn winding & rewinding the fan with superior quality rewinding wire & filling the varnish as insulation between each winds & covering each loops of winding by sleeves & paper & reassembling of complete fan by fixing serviceable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes, ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing, oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep. Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out serviceable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No on fans (v). Unserviceable /defective retrieved parts shall be credited vide sch of credit. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans shall be repaired/rewind at AGE E/M store yard only.
All as per srl item No 1.45 here-in-before but for 1400 mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.45 here-in-before but for air circulation fans, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.45 here-in-before but for Exhaust fans of 225/250mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.45 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.45 here-in-before but for Exhaust fans of 450mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.45 here-in-before but for wall cabin fans of 400mm sweep, complete all as specified and as directed by Engr-in-charge.
supply GI 'U' clamp heavy duty rubber reel of superior quality and nut and bolts with locking arrangement complete including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only PVC canopy cover superior quality all as specified and as directed including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only down rod 60cm long made out of 15 mm bore light grade GI pipe having provision of fixing U clamp & Fan including painting the pipe with superior quality white colour synthetic enamel paint all as specified including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.54 here-in-before but 1m long, complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED batten fitting 10-12 watt, 2 feet, including driver, tube rod warm/cool, aluminium body industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing LED surface mounted bulk head luminaries 8-10 W with min 800 lumen ,industrial model, IP 65, Aluminum housing, surge protection including drivers & led lamp etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
M&L for cleaning the fan motor assembly body, blade of ceiling fan, filling the cavity rubbing with sand paper, taking off old paint with the help of chemicals & painting the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint including writing the MES number on the ceiling fans of 1200mm sweep with black colour synthetic enamel paint complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.58 here-in-before but for 1400 mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.58 here-in-before but for Exhaust fans of 225/250mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.58 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by Engr-in-charge.
All as per srl item No 1.58 here-in-before but for Exhaust fans of 450mm sweep, complete all as specified and as directed by Engr-in-charge.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only bearing No 6203 for 1200/1400mm sweep ceiling fans including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only capacitor 4 MFD dry type including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only fan blade suitable for 1200 mm sweep fan of existing make including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply only fan blade suitable for 1400mm sweep fan of existing make including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply & Fixing LED Flood lights, 120 watt IP-65, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed.
M&L for arresting the leakage of the geyser by applying brazing to inner tank and refixing the inner tank after making it functional all as specified and as directed by Engr-in-charge. Note : Adequate water pressure will be apply to the brazed tank to ensure that no leakage is left if the tank is still leaking the same will be repaired by the contractor the cost to be deemed to be included in the quoted rate.
Supply & replacing heating element of 1.5/2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating element, complete all as specified and as directed by Engr-in-charge.
Supply & replacing heating element ISI mark cup or triangle type of 1.5/2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating elements all as specified and as directed by the Engr-in-charge.
Supply & replacing thermostat switch for geyser of any type ISI marked including taking out old unserviceable thermostat switch all as specified and as directed .
Supply & replacing geyser inner tank assembly suitable for geyser capacity of 25 Ltr including taking out old unserviceable tank assembly all as specified and directed.
Ditto as per item No 1.75 here in before but 50 ltr capacity, complete all as specified and as directed by Engr-in-charge.
Supply &replacing inner tank for geyser of 25 Ltr capacity including taking out old unserviceable inner tank all as specified and as directed by Engr-in charge.
S&F Chromium Plated non return valve 15mm bore with air lock release arrangement ISI marked including taking out old unserviceable non return valve, complete all as specified and as directed by Engr-in-charge.
Supply & replacing metal clad socket top as per existing socket including taking out old unserviceable metal clad top complete all as specified and as directed by Engr-in-charge.
Supply & replacing of inspection cover stainless steel in 2 piece suitable for geyser of 50/25 ltr capacity and having provision of fixing indicator lamps including taking out old unserviceable inspection covers all as specified and as directed by Engr-in-charge.
S & F in replacement flexible cable PVC insulated 3 core circular stranded copper conductor of 2.5 sqmm including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
S & F in replacement flexible cable PVC insulated 3 core circular stranded copper conductor of 1 sqmm including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
S&F Chromium plated gate valve of 15 mm bore suitable for fixing on existing fittings including taking out old unserviceable gate valves complete all as specified and as directed by Engr-in-charge.
S&F brass connection pipe having wire mesh coating over it with PTMT nuts and washers suitable for connecting geysers inlet and outlet with GI tubings including taking out old unserviceable brass connections complete all as specified and as directed by Engr-in-charge.
S&F GI tubing 20mm med grade with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site including removing Unserviceable items complete all as specified and as directed by Engr-in-charge. Note: rate quoted will deemed to include the plumber work as per site requirements.
S&F top plug 15 Amp 3 pin including taking out old unserviceable plug top including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
S&F indicating lamp green/red in colour 230 volts as per existing make including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
S&F Automatic 1HP pressure Pump with Pressure control switch with fully automatic water level controller including removing Unserviceable items all as specified and as directed by the Engineer-in-Charge.
S&F in repair mirror light 9/12W LED wall mounting fixture, compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing Unserviceable items all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair modular PVC sheet/cover plate 3 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair modular PVC sheet/ cover plate 4 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair modular PVC sheet / cover plate 6 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing Unserviceable items, complete all as specified and as directed by Engr-in-charge.
S&F in repair modular switch 6 Amp 1 way 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair switch modular 16 Amp 1 way 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair socket modular 2/3 pin 5 Amp 2 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair socket modular 6 pin 6/16 Amp 2 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair of electronic Fan regulator modular 120 watt 2 module complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair modular bell push 6 Amp 1 way 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Contractor or his rep (Tradesman) will report at service center daily at 0845 hrs, will receive the complaints lodged by user and attend/complete the complaints, will give feed back about the complaints to JE/AGE daily at 1700 hrs. The complaints which are not attended by the contractor on same day will be penalized @ Rs 150.00 per day except for items Ser Nos 1.05 & 1.06. Complaints will be signed by user/user rep or in absence, by concerned JE. Final decision in case of dispute whether the complaint has been rectified or not will be of concerned JE/Engr-in-Charge.
M & L attending day to day internal electrician complaints received via Armaan, off line, Maintenance Mela or through other means & electric audit for preventive electric maintenance by electric alongwith the helper with required tools, transportation & safety devices on all working day from 0900 hrs to 1700 hrs (or in emergency in non- working hours & around the clock) . Any complaint requiring replacement of item will be paid in S & F under respective items of CA.
Site/ complaints will be given on daily basis & not at a glance as the contract pertains to day to maintenance of E & M services.
Contractor has to bring supply & fix items of the CA at E & M service center in quantum as mentioned by Engr-In-Charge. The same will be issued on daily basis to tradesmen employed by contractor against complaints registered by users.
Contractor will hand over the dockets & UNSV item at service centre daily at 1700 hrs or within 24 hrs.
The UNSV item as per schedule of credit will be handed over to the contractor after payment only.
Progress of work will be measured on daily basis on restoration of complaints/jobs.
Contractor has to submit the following details of tradesmen employed by him:- (a) Police verification (b) Qualification certificates (c) Aaadhar Card
For LED luminaires the following measures will be observed:- (a) Local representative of the company will certify the compliance of the specification of the luminaire and genuineness at site. The rep will also certify the genuineness of PVs. (b) Contractor shall also submit the third party LM-79 & LM-80 report of the fittings from certified labs. (c) Two year warranty certificate not signed below the rank of regional manager to be submitted by the contractor.
Payment will not be progressed without submitted the above mentioned documents & PVs
The rates quoted shall be deemed to include provisions of above points.
R N Enterprises
Saurav Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .