| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Acceptance | |
| 2 | L2₹42.0 L+₹3.2 L (8.29%)Rejected-AOC INDEX NO E 1504 HQ CWE DEHRADUN 63 RAJA ROAD DEHRADUN | L2 | Rejected-AOC R | |
| 3 | L3₹43.0 L+₹4.3 L (11.0%)Rejected-AOC 63 MANDIR LANE BALLUPUR CHOWK DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC R | |
| 4 | L4₹44.9 L+₹6.2 L (16.0%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L4 | Rejected-AOC R | |
| 5 | L5₹48.2 L+₹9.5 L (24.5%)Rejected-AOC 20 C RAGHUVANSH ENCLAVE KALIDAS ROAD DEHRADUN | L5 | Rejected-AOC R |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
9 Oct 2021, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
SPECIAL REPAIR TO BLDG NO P317 AND P318 NEAR SWIMMING POOL AT IMA DEHRADUN
2021_MES_468036_2
GE/IMA/80/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
9 documents required · 9 mandatory
₹500
Yes
GE IMA Dehradun
₹86,000
Yes
27 Oct 2021
16 Sept 2021
11 Oct 2021
16 Sept 2021
9 Oct 2021
24 Sept 2021
Amount
Dismantling timber scantling 40 Sqcm and over in section, framed work, in any position complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key, scdrubbing down with water etc complete all as specified and directed.
Pre- painted colour galvalume aluminium Zinc coating GI based corrugated tile profile steel sheet 0.50 mm thick of colour as per swimming pool roof having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as directed including dismantling existing AC sheet.complete all as specified and directed
Pre- painted colour galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding ridges to wall fixed with self tapping screws etc including dismantling existing AC complete all as specified and directed
Rolled structural mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00 m mean radious built in CM (1:6) including demolition of brick work/stone masonry built in cement mortar complete all as specified and directed
Rendering 15mm thick plaster on other than fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and mixed with water proofing compound as per manufactures instructions, complete all as specified and directed Note- WPC will be measured paid as supply only under respective items separetely.
Rendering 15mm thick plaster on fair faces of brick or concrete surfaces in CM 1:3, finished even & smooth without using extra cement complete all as specified and directed
Rendering 10mm thick plaster on concrete surface in CM (1:3) on ceiling finished even and smooth without using extra cement complete all as specifiied and directed.
Supply only liquid water proofing compound complete all as specified and directed
PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps,seismic and other similar bands,coping, benching, kneelers, apex stone, bed plates, kerbs etc including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as specified and directed.
12 mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish including finishing with two coat of oil bound distemper over a coat of primer over a coat of plaster of paris putty including dismantling existing ceiling complete all as specified & directed. Note :- (i) The work shall be carried out above 7.5m height. (ii) Arrangement to be made in the ceiling accommodate the light fittings & fixtures. (iii) The rate quoted shall be inclusive of scaffolding upto required height and all T&P reqd to complete the work.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channe 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including dismantling existing frame work complete all as specified & directed. Note :- (i) The work shall be carried out above 7.5m height. (ii) Arrangement to be made in the ceiling accommodate the light fittings & fixtures. (iii) The rate quoted shall be inclusive of scaffolding upto required height and all T&P reqd to complete the work.
75 mm thick PCC 1;3:6 type C-2 using 40mm graded stone aggregate as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and including demolition of existing old cement concrete, complete all as specified and directed.
Vitrified ceramic tiles 10 mm thick light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 15 mm thick screed bed or bedding layer in CM 1:4 complete and dismantling of existing floor tiling including cement mortar bedding and rubbish off the premises complete all as directed.
Dismantling boarding any description fixed in any position as in court floor all as specified and directed.
Post construction Anti termit treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
Post construction Anti termit treatment along the external wall below concrete or masonary apron using camical emulsion @ 2.25 ltr per linear meter including driling and plugging holes etc in apron, complete all as specified and directed.
M&L for Squash court of size 9.8m x 6.4m wood parkett floor HARO squash with the following:- (I) Elastic bearing elements made of spruce, classification I/III, fully planed, with rubber pads, dimensions : 4000mm x 95mm x 37 mm. (ii) Counter sub- floor made of spruce, classification I/III, fully planed, with rubber pads, dimensions : 4000mm x 95mm x 17 mm. (iii) PE foil, sports floor according to DIN280, Para5, Thickness 0.3mm. (iv) Haro parquet squash floor of 12.5mm thick including 3.6mm ASH solid hardwood top layer, slip resistant SST surface with special polish and depth impregnation stapled on to the counter floor.. (v) Haro parquet squash floor dimensions :2200mm x 180mm x 12.6mm (vi) Flooring construction height: Approx 66.6mm, required height on site – 70mm Note :- (i) The product used should be WSF approved and certificate for the same to be submitted. (ii) It will be responsibility of executing agency to arrange the visit of representative of world squash federation through their Indian counterpart the Squash & Racquet federation of India ( (S & FI) for approval & certification physically on site after execution of Squash courts flooring on site.
PCC 1;4;8 type D-2, using 40 mm graded stone agg as in foundation, filling, mass concrete and sub base of floor including demolition of existing old concrete complete all as specified and directed
Rubberised polished precast coloured concrete Interlocking paver block any shape,size & colour confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete with & including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified & directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area n.exc 1.50 Sqm each complete all as specified & directed.
Powder coated aluminium Anodized frame for doors , windows, ventilators, partition wall with one or more rebates including joining cleat for fixing etc fixed in repair complete all as specified. (Minimum thickness of powder coating not less than 50 micron) complete all as directed
Powder coated aluminium decorative grill of approved design for windows/vent including side channel fixed with brass/ stainless steel screw including cutting the grill to proper opening size for fixing & operation of handles etc complete all as directed.
5.5mm thick glass fixed in aluminium door/window/partition fixed with rubber gasket and aluminium beading complete all as directed.
12 mm thick colored pre laminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in partitions, cup board shutter / shelves, pelmet box and similar items fixed in repair complete all as directed.
Floor door stoppers of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in door, overall length of cover plate 150mm complete all as specified and directed
Double action floor spring hydraulically regulated made up of min 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified & directed.
200mm long aluminium anodized barrel tower bolt of extruded section complete all as directed.
250mm long aluminium anodized sliding door bolt with hasp staple (bolt type) and fixing clips to sheet cast or extruded section of cast aluminium complete all as specified and directed.
150mm long aluminium anodized handle cast type complete all as specified and directed.
Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed
3mm thick wall care putty on wall complete all as specified and directed.
Preparation of wall surfaces and finishing with Acrylic Smooth exterior paint of required shade with (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash etc complete all as directed.
Preparation of new plastered surfaces of wall of any description over 10 Cm width or girth and applying two coat of synthetic enamel paint over a coat of primer including marking lines as per squash court pattern etc complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound emulsion over a coat of chalk whitening complete all as directed
Examining concrete by tapping with light hammer and marking of the loose concrete area of structural elements in straight line, grooving the edges with grinder upto 5-10mm depth with out damaging existing rebars, carefully removing carbonated concrete around the rebars upto 10mm depth by low impact high frequency hammer/chipper with out damaging the sound concrete and removing the debris from site complete all as specified and directed
Cleaning existing reinforcement with wire brushes/rotary wire brush to make surface free from rust scales, loose materials, dirts etc complete and providing and applying two coats of alkaline rust removing primer (Sika Rustoff – 100 or equivalent) with a coverage of 350gm/Sqm on existing rebars and allowing it to react with rust for 6 hours to form corrosion resistant, insoluable and adherant protective layer including cleaning cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats. complete all as specified and directed.
Providing and applying of zinc rich epoxy anti corrosive protective coating for rebar corrosion protection system. Friazinc® R or equivalent in two coats of 0.4 kg/sqm. The product should confirm carbonation resistance of 2mm and bond strength > 1N/mm2 according to ASTM C 882- 78.complete all as specified and directed.
Preparing prepared RCC surfaces as per manufacturar's instructions by chipping and theroly cleaning complete as per directions of Engineer-in-Charge and providing, mixing & applying two component Epoxy resin concrete Bonding coat Sikadur®-32 LP or equivalent in Consumption of 0.4 kg/sqm. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 Mpa complete all as specified and directed.
Rebuilding the section of structural damaged spalled concrete or RCC elements to its original size as per recommendations of Engineer-in- charge in thickness upto 40mm in two layers of 20mm each of average thickness 30mm by providing and applying pre- batched, one component fiber reinforced cementitious patch repair mortar Sika®Mono Top®-122F or equivalent having compressive strength strength >= 5N/ mm2 ( 7 days) according to ASTM C293-79.complete all as specified and directed.
Mild steel TMT bars 8mm dia and over, bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed. Additional reinforcement with adequate lap length & rings as required spacing shall be tied with existing reinforcement using binding wire or welded complete as per site requirement and directions of Engineer-in-charge.complete all as specified and directed.
Cleaning of roof slab, chajja including picking, sweeping, cleaning and washing with water to remove dust including taking down of existing roof treatment and providing water proofing treatment as under:- (a) Applying a coat of STAR PROOF MB-602 with help of brushes on the cleaned RCC slab/Chajja after repair of any depression/damaged surface of roof with suitable repair mortar of asian & equivalent. (b) Laying a layer of fiber cloth on wet MB-602 coating and applying another coat of MB-602. (c) After drying of surface finally applying two coat of STAR PROOF SP-600 of any colour as per manufacturers instruction. (d) The work of water proofing treatment shall be got executed as per manufacturer instruction through expert team or authorized applicator of M/s Star SSPL.
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all specified and as directed
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including PVC conduit concealed and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLSH as continuous earth conductor, connected to earth dolly by providing suitable lugs with inner and outer frame plate matching with surrounding with sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets etc complete for the following:- Note:- (i) Point wiring & earth wire shall be connected to each & every sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) Modular cover plate with frame and sunken steel boxes zinc oxide plated as per site requirements shall be included in quoted rates.
One light point/fan point controlled by one, one way Modular switch 6 Amps
One fan/exuast fan point controlled by one, one way Modular switch 6 Amps
One 5 pin 5 Amps switch socket outlet point controlled by one Modular switch on independent boad.
One 5 pin 5 Amps switch socket outlet point controlled by one modular switch on the same board.
Description all as per item No 48 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
Modular switch single pole one way 6 Amp complete all specified and as directed.
Modular switch single pole one way 16 Amp complete all specified and as directed.
Modular socket outlet 2/3 pin combined 6 Amp 240 volts complete all specified and as directed.
Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all specified and as directed.
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all specified and as directed.
MCB DB, sheet metal enclosures double door SPN 12 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as specified and directed.
Extruded aluminium surface and wall mounted LED batten fitting, 25 W, 230 volts AC , with all accessories complete suitable for and including 25 W LED tube rod complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as directed. Make: Philips cat part No. BN021C LED 25S 6500PSU CW GR S1 or equivelent of Wipro/Havells.
Supply and fix building security light fitting 1x30 W new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with mid power led as lighting source and PC cover having top opening seperate driver compartment with IP 66 protection and impact resistance of IK 07 including suitable size of bracket bend in shape with 2 Nos of clamps,nuts,bolts etc including taking down existing fitting etc all as specified and directed. .Make:- Wipro Product Code LR02-331-XXX-57-XX or equivallent of Philips/Havells.
Supply and fix in replacement of metal body exhaust fan 300 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Turbojet SP of Havells and equivalent of Bajaj/Usha.
Wall fans 230 Volts single phase oscillating 400 mm sweep with remote white suitable for wall mounting complete all as specified and directed. Make:- Havells, Model No. Platina Remote (SKU- FHWPTRCWHT16) or equivalent of Bajaj/Usha.
Supply and fixing of LED luminaire for Squash court with a housing of Pressure Die casted Aluminium and cover of toughened and shatter-proof quality polycarbonate to ensure protection. The luminaire should have a color consistency SDCM < 5, CRI > 70 and CCT of 5700K. The luminaire shall be compliance with IP65 classification and impact protection of IK08 to ensure durablility. Luminaire shall be designed to emit at least 10000 nominal lumens at a system efficacy of atleast 100 lumen/watt and maximum system wattage of 100W. Make:- Philips Cat No: BY515PLED100S 5700 NB PSU GR or equivalent of Havells/Wipro.
Supply and laying or fixing or passing through pipe XLPE insulated, armoured, heavy duty electric cables 1100 volts grade with stranded aluminum conductor of size 16 sqmm 2 core laid in trenches /duct /wall /floor etc complete all as specified and directed.
Excavation in trenches n. exc. 1.5M wide and n. exc. 1.5M in depth for laying cable/taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed.
Un-reinforced precast concrete cable cover class LV type1 flat size250 mmx 150 mm x40 mm as protection to under ground cable laid dry flat adjjoining each other complete all as specified and directed
Supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
GI pipe light grade ISI marked 40mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah with calmps, bolts, nuts & washers etc complete all as specified and directed.
MCB SPN 40 to 63 Amps, 240 volts ,50 HZ, including connection with suitable size copper lugs complete all as specified and directed. Make:- Legrand, cat part no 408618 to408620 or L&T, ABB, Schneider, C&S
MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed. Make:- Legrand, cat part no 408587 to408595 or L&T, ABB, Schneider, C&S
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI earth strip 25mm X 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Amit Traders
Meher enterprises
M/S S P BUILDERS
shreyansh construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .