Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC | L1 | Accepted-AOC Contract Awarded | |
| 2 | L2₹4.5 L+₹20,510 (4.83%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹5.0 L+₹72,955 (17.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹5.5 L+₹1.2 L (29.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹6.0 L+₹1.7 L (40.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
14 Dec 2022, 6:00 pmClosed
AGE (I) Dharamshala
AGE (I) Dharamshala PIN-176216
Repair/replacement of existing unserviceable point wiring, fittings, service connections and other connected works in Tirah Line at Mil Stn Dharamshala
2022_MES_563737_1
AGE(I)/DSL-34/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Tirah Lines
As per NIT
7 documents required · 7 mandatory
₹500
AGE(I) Dharamshala
₹14,000
Yes
2 Jan 2023
17 Nov 2022
16 Dec 2022
17 Nov 2022
14 Dec 2022
1 Dec 2022
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings such as bend/corners/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core(Green colour) cable as continuous earth wire connected to common earth dolly in existing CI/wooden/pvc box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. Note :- (i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost
All as per item No 2.00 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2.00 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2.00 above , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for switch socket combination 2 in 1, 5 Amp and 15 Amp flush type complete all as specified and directed by Engr-in-Charge.
M&L for Switch socket combination 2 in 1, 5 A flush type, complete all as specified and directed by Engr-in-Charge.
M&L for switch piano flush type single pole one way 5/6 Amp, complete all as specified and directed by Engr-in-Charge.
M&L for Bell push Switch flush button single pole one way 5 Amps complete all as specified and directed by Engr-in-Charge.
M&L for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
M&L for plug top of 15 Amp complete all as specified and directed by Engr-in-Charge.
Sub main wiring in PVC casing caping/conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 4 sqmm multistrand and 2.5 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar complete all as specified and directed by Engr-in-Charge. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing surface.
Supply and fix amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SP 5 to 32 Amp MCB complete all as specified and directed by Engr-in-Charge.
Supply and fix amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SPN 32 Amp MCB complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of existing unserviceable FTL with new technology ultra bright LED tube rod and polycarbonate diffuser having high efficacy suited for installation in existing T5 or T8 tubelight with G5 lamp holders to give glare free light of capacity 18W LED double side connection including neccessary electric conection with batten complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of existing unserviceable batten with BOX TYPE Pre-coated CRCA body, heavy duty regaL Batten for LED tube universal batten for G13 T5 or T8 lamps including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. .
Supply and fix in replacement of existing unserviceable FTL with new technology ultra bright LED tube light batten fitting with aluminium housing and integrated electronic driver to give glare free light of capacity 10W 865 fixture size (592x23x37mm) LED including necessary electric connections from ceiling rose to connector, complete all as specified and specified and as directed by the Engr-in-Charge.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
M&L for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 15/18 watts for batten fitting, including plastic square board of required size complete all as specified.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed by Engr-in-Charge.
M&L for call bell ding dong AC 230 volt single pole complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I & complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with DB’s suitable for MCBs of triple pole and neutral 4 way, 415 volt, double door type with 200 amp rated bus bar double door type with one incoming and 12 outgoing complete all as specified and directed by Engr-in-Charge. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing surface.
Supply and fix in replacement of MCB TPN/FP 40 to 100 Amp complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Taking down exhaust fans 225/ 300/ 380/ 450 mm sweep, and then properly cleaning and greasing of bearings after opening of the fan including replacement of unserviceable parts, reassembling and reconnecting of exhaust fan complete all as specified and directed by Engr-in-Charge. Note: - Spare parts will be measured and paid separately at 'supply only rates'.
Supply only ball bearing of exhaust fans of any size and type all as per site requirement including greasing, complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC/ABC
M&L for rewinding of exhaust fan of 225 to 300 mm sweep complete with super enameled insulated copper wire of appropriate size , including all winding, insulating material and impregnation of insulating varnish as per detail given below of any make, type, model including transportation from AGE E/M store yard to site of rewinding complete all as specified and directed by Engr-in-Charge.
All as per item No. 30.00 above but exhaust fan of 450 mm sweep complete all as specified and directed by Engr-in-Charge.
Painting of exhaust fans after due preparation of surface 225/300/380/ 450 mm sweep complete at site with super enamel synthetic paint of colour as per old one by spray gun including filling cavities with filler, two coats after cleaning all dust, grease, smoke spots etc complete all as specified and directed by Engr-in-Charge.
Supply only copper alloy bush of exhaust fan any make and size all as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply only the deshaped blade from exhaust fan of any size complete all as specified and directed by Engr-in-Charge.
Supply only capacitor of size 2.5/3.5 MFD for ceiling fan complete all as specified and directed by Engr-in-Charge.
Supply only bolts,nuts and washers,rubber reel, split pin of appropriate size as required at site for ceiling fan of any size complete all as specified and directed by Engr-in-Charge.
Taking down carefully from wall after unscrewing nut/bolts geyser 50/35/25 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc and reassembling and refixing after repair all as specified and as directed by Engr-in-Charge. Note:-(I)- Spares parts shall be measured and paid separately under respective items of Sch 'A' BoQ. (ii)- Spare parts shall be replaced with existing make of geyser.
Supply only heating unit (element) ISI marked of 1500 watts triangular shape rating as required at site including rubber washers complete all as specified and directed by Engr-in-Charge. (As per sample)
All as per Serial item No 38.00 above but circular shape, complete all as specified and directed by Engr-in-Charge.
Supply only internal steel tank of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , all as specified and directed . Note-: The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor.
Supply only internal steel tank of geyser 50 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , all as specified and directed . Note-: The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor complete all as specified and directed by Engr-in-Charge.
Supply only of syphon assembly made out of brass of 50 ltr capacity including necessary studs screws and rubber gasket/washers complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 42.00 above but 25 ltr capacity complete all as specified and directed by Engr-in-Charge.
Supply and replacement glass wool of 25 ltrs capacity geyser complete all as specified and directed by Enginner-in-Charge.
All as per sl item 44.00 above but in 50 ltrs capacity geyser complete all as specified and directed by Engr-in-Charge.
De-scaling of geyser of capacity 25/50 ltr after taking down the geyser from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of geyser complete all as specified and directed by Engr-in-Charge.
Supply and replacement PVC connection 15mm dia complete with brass flair nuts at both ends. (ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed by Engr-in-Charge.
Supply and replacement brass pressure relief valve chromium plated suitable for geyser 25/50 ltr capacity complete all as specified and directed by Engr-in-Charge.
Supply and fixing anchor bolt 12mmX100mm long complete all as specified and directed by Engr-in-Charge.
Supply and replacement of defective mild steel base plate cup any type with screws of suitable size as per requirement complete all as specified and directed by Engr-in-Charge.
Supply only ISI marked thermostat range 0°-75°C for the geysers of 25 to 50 Liters capacities complete all as specified and directed by Engr-in-Charge.
Supply only 15mm stop valve CP fancy type,cast copper alloy,screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable complete all as specified and directed by Engr-in-Charge.
Supply only non return valve 15mm dia cast copper alloy ISI mark complete all as specified and as directed by Engineer-in-charge.
Supply only Indicator lamp rectangular/ round type, complete all as specified and directed by Engr-in-Charge.
Supply only GI union 15mm dia complete for fixing the non return valve complete all as specified and as directed by Engineer-in-Charge
Cleaning / scrapping of old paint/dust and painting of geysers of 25/35/50 litres capacity at site/ stores with two coat of super enameled painting by spray complete all as specified and directed by Engr-in-Charge.
Supply and fixing Exhaust fan louvers with nuts, bolts, washers and all fitting material at site for complte the works, making good existing surfacewith existing colour complete all as specified and directed by Engr-in-Charge.
Supply and fix mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets,bends,elbow,unions,tees diminishing pieces etc, fixed to wall or ceiling or in floor complete all as specified and directed by Engr-in-Charge.
Him Builders
Krithvik Electricals
KISHAN CONTRACTOR
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .