| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC AOC | |
| 2 | L2₹17.2 L+₹43,994 (2.62%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹21.7 L+₹4.9 L (29.2%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
27 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (I) (CG) Goa
Garrison Engineer (I) (CG) Goa HQ Coast Guard DHQ-11 Chicolna PO- Bogmalo Goa 403806
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY UNDER TECH AND NON TECH AREA AT GOA UNDER GE(I)(CG) GOA
2023_MES_620758_1
8421/GOA/E8
Open Tender
Miscellaneous Services
Item Rate
180 days
TECH AND NON TECH AREA AT GOA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Goa
₹48,000
Yes
27 Dec 2023
27 Sept 2023
4 Nov 2023
27 Sept 2023
27 Oct 2023
12 Oct 2023
27 Sept 2023 - 4 Oct 2023
Amount
Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wide and getting out in hard dense soil for taking up/relaying LT UG cable/ pipe Complete all as specified and directed.
All as per Item No 1.00 above but in soft disintegrated rock/ laterite rock. Complete all as specified and directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata. Complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5m above the starting point. Complete all as specified and directed.
Supply & Lay dry river sand/ M sand in trenches for cable protection. Complete all as specified and directed. [Note : Only Punned thickness will be measured & Paid]
Supply and lay cable cover LV type 1 flate size 250 X 150 X 40 mm for cable protection. Complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 95 Sqmm 3.5 core including taking out old unservicable cable.Including testing Complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 70 Sqmm 3.5 core including taking out old unservicable cable.Including testing Complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 50 Sqmm 3.5 core including taking out old unservicable cable.Including testing Complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 16 Sqmm 4 core including taking out old unservicable cable.Including testing Complete all as specified and directed.
M & L in replacement for GI pipe light grade laid in trenches for cable protection of size 50mm dia. complete all as specified and directed
M & L in replacement for GI pipe light grade laid in trenches for cable protection of size 80 mm dia. complete all as specified and directed
S & F in replacement of Lugs of 16 sqmm to 50 sqmm complete all as specified and directed.
S & F in replacement of Lugs of 70 sqmm to 185 sqmm complete all as specified and directed.
S & F in replacement danger notice plate of 1.6 cm thick mild steel vitreious enamelled white, with letters, figures and conventional and boxes in signal red colour and fixed with MS clamps, bolts & nuts of approved size for HT 25 x 20 cm size complete all as specified and directed.
S & F in replacement danger notice plate of 1.6 cm thick mild steel vitreious enamelled white, with letters, figures and conventional and boxes in signal red colour and fixed with MS clamps, bolts & nuts of approved size for LT 20 x 15 cm size complete all as specified and directed.
M & L for repairs to LT/HT pillar box by opening door hinges and taking rusted portion of door incl removing bends / dents and refixing the door with new hinges, handles, making good surfaces bolting etc and painting of LT pannels by duly cleaning the surface from dust and grease and applying one coat of synthetic enamel paint by using spray gun colour as directed by the Eng-in-Charge and lettering the LT pannels with black/white paint using stencils or making lettering by using stickering with minium size of letter to be of 5 Cm all as specified and directed
M & L for cement painting of with prepared white ( snowcem ) for transformer /LT /HT poles plitnth area/ Copings of any size all as specified and directed ( including scrapping & cleaning with wire brush ) complete all as specified and directed.
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 250 Amps/25KA, 4 Pole adjustable type complete all as specified and directed.
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 160 Amps/16KA, 4 Pole adjustable type complete all as specified and directed.
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 125 Amps/10KA, 4 Pole adjustable type complete all as specified and directed.
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 100 Amps/10KA, 4 Pole adjustable type complete all as specified and directed.
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 63 Amps/10KA, 4 Pole adjustable type complete all as specified and directed.
Preparation of surfaces RCC Pole of 9 mtr by scraping with emry paper and making free from rust, dust and any foreign material and apply two coats of ceament based weather proof distemper including letter writing on poles such as Pole No and source point of electric supply with black paint and flurcent paint in circumference of poles / mast towers of various heights complete all as specified and directed.
Taking down street light fitting from pole for repairing / replacement / cleaning of any Wattage, including removing dead insect, dust and refixing again to same location complete all as specified and directed. [Note:- Replacement of accessories like Ballast, ignitor, lamp will be measured & paid seperately]
S & F in repairs PVC FRP junction box with 01 No MCB SP of 6 Amp fixed on existing pole with clamp, nut & bolt connections including removing dismantling of unserviceable pole box and MCB complete all as specified and directed.
S & F in repairs FRLS PVC insulated copper conductor 2x 2.5 sqmm+1x 2.5 sqmm earth wire in PVC conduit from fitting through the bracket to DB sintex box complete all as specified and directed. [Note: 2 run of 2.5sqmm, 1 run of 1.5 sqmm and 20mm PVC conduit will be measured as one length]
Taking down unserviceable indication lamp and supply & fix and testing indication lamp (LED type) with showing red, yellow and green in colour of 22.5mm dia monitor on HT/LT panel board suitable for 240V AC supply complete all as specified and directed.
M & L Painting of steel tubular electric poles 9.0 mtr long with two coats of aluminium paint over a coat of red oxide primer after preparation of surface approved colour and quality including marking and painting with black & yellow colours strips with coping level and making of Pole Number complete all as specified and directed.
S & F in repairs LED street lights 70W new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover havint TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device and giving electric connection and testing complete all as specified and directed.
S & F in repairs LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.complete all as specified and directed.
S & F Astronomical Programmable in replacement every 1 min, back up of 10 years, 28 memory locations, with built in battery Digital time switch Current carrying capacity of 16A with 1CO all as specified and directed by taking down the old damaged timer complete all as specified and directed
S & F contactor in replacement, 4 pole, 415V, 40A cap, MCX , 2 NO+2 NC utilsed for heavy duty by taking down the old perished / deteriorated contactor aganist repairs complete all as specified and directed
Servicing and repairing/ carryingout maintenance of 11KV/440V transformer including the following works for 500 KVA capacity as follows (Complete all as specified and directed.): - (a) Disconnecting the transformer from plateform, electrical connection from HT & LT side, earthing side , lifting with the help of crane transporting to trade work shop and unloading all as specified. (b) Dismantling the transformer, drain out trransformer oil, lift the cover, coil assembly & keep up the assembly in oven upto the preparation. Scratching the body with wire brush for any carbon deposite and oily substance from the transformer. (c) Cleaning the core iron sheet laminations assembly by oil complete, removing carbon sediments, dust in the coil and core gently without making any damage to coil and core. (d) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil. (e) Lifting the transformer from trade workshop, transporting back to site. Unloading on the platform connecting the transormer with foundation, electrical connection to HT, LT and earthing side, testing and commissioning for satisfactory performance. Note: (i) Transformer oil filteration and topup of new oil will be measured seperately. (ii) All petty parts including nut, bolts, gasket and minor weldings /patch work are deemed to be included in the rate quoted. (iii) The rate for lifting by crane, transporting, unloading are deemed to be included in the unit rate quoted.(iv) All major parts if any replaced and rewinding of HT & LT coil are not included in the unit rate mentioned . Same will be priced and measured seperately under relevant items of Sch.
All as per item No 35.00 above but up to 400 KVA. Complete all as specified and directed.
All as per item No 35.00 above but for 250 KVA. Complete all as specified and directed.
All as per item No 35.00 above but up to 200 KVA. Complete all as specified and directed.
All as per item No 35.00 above but for 100 KVA Complete all as specified and directed.
All as per item No 35.00 above but up to 63 KVA. Complete all as specified and directed.
Attending electrical breakdown in the distribution transformer by repairing the same by arresting the sparking on HT & LT side by securing the joints, replacing the HT fuses, nuts, bolts in the spot for restoration of supply for upto 500 KVA transformer. Complete all as specified and directed.( A payment shall be maid after submitting necessary breakdown report duly sign by Engr-in-Charge.
Supply only HT bushing insulator, Brass metal studs nut & washers suitable for HT bush side of transformer up to 500 KVA. Complete all as specified and directed.
Supply only LT bushing insulator, Brass metal studs nut & washers suitable for LT 415 Volt bush side of transformer up to 500 KVA capacity of transformer. Complete all as specified and directed.
Supply and fill new EHV grade insulating transformer oil complete with minimum BDV 60 KV all as specified and as directed by Engr-in-charge. Complete all as specified and directed. [Note:- Purchase voucher and test certificate to be produced to Engineer in charge for claiming of payments]
Filteration of existing transformer oil with high pressure vaccum filteration plant to improve dielectric strength of insulating oil including testing for BDV of the filteration oil not to be less than BDV 60KV. Complete all as specified and directed.. Note :- (a) Rates includes the requirement of tools/plants at site where transformer oil to be filtered. (b) Transformer shall be kept in OFF position during filteration. (c) Temperature of oil should be kept below 75 ' C' during filteration. (d) Filteration report to be kept in safe entity by Engineer in charge
Supply & Fill in repairs existing breather silca jel of superior quality for transformer breather. Complete all as specified and directed.
S & F in repairs breather unit of transperant PVC material including its replacement for transformer of capacity up to 500 KVA. Complete all as specified and directed.
M & L Disc type porcelain vitreous, brown or white insulator to suit 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete including dismantling existing old insulator from position. Complete all as specified and directed.
M & L Pin type porcelain vitreous,brown of white insulator to suit 11 KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete including dismantling existing old insulator from position. Complete all as specified and directed.
M & L Post insulator suitable for 11 KV HT working pressure including all connected accessories including dismantling existing old insulator from position. Complete all as specified and directed.
Replacement of ACSR type jumpers(appx 1.5 RM in length) of suitable dia incl aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints,applying jelly to each contact points and GOD male & female contacts and dismantling old jumpers. Complete all as specified and directed.
Taking down 11 KV air break gang operated switches vertical / horizontal mounted including insulators and operating mechanism for insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc. Complete all as directed.
M & L outdoor type Gang operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame,with operting mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps suitable for vertical mounting fixed type complte with 15 Nos HT insulators suitable for HT 11 KV . Complete all as specified and directed.
M & L Lightning Arrestor (LA) zinc oxide type complete with all fittings transmission class, discharge capacity 10 KA, suitable for 11 KV and removing old existing unserviceable one . Complete all as specified and directed.
Supply only in repairs HT Fuse element of HT 11KV, 10 Amp to 30 Amp rating . Complete all as specified and directed.
Dismantling of MS cross arms bracing support clamps nuts bolts and washers etc and M/L for cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles all as specified and directed incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces. Complete all as specified and directed.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 Sqmm to 120 Sqmm Complete all as specified and directed.
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm Complete all as specified and directed.
M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25m deep below the ground level with top to edge of the plate n. less than 1.5m below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing. Complete all as specified and directed.
M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe of suitable dia and required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing. Complete all as specified and directed..
S & F in repairs AAC(All Aluminium Conductor) for binding purpose of not less than 0.9mm dia for tightening the conductors on poles. Complete all as specified and directed.
M & L Graded coarse aggregate (broken stone or boulders) of size 40mm in substation yard for laying. Complete all as specified and directed. [Note:- Stack measurment of materia to be entered in MB]
M & L for servicing /testing and calibration of line breaker/control panel including outdoor CT, PT and relays in control panel of indoor VCB of capacity 630/400A Amps and rating 11 KV as details mentioned as under complete all as specified and directed:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Visual check for rust and deformation. (ix) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (x) Check for loosened connections, rust, damaged lead wires. (xi) Checking of control circuit & tighten the connections if any. (xii) Check close & trip coil. (xiii) Replacement of Dashpot/shock absorbers . (xiv) Replacement of carbon brush of spring charging motor (xv)Cleaning of porcelain bushing (xvi)Checking of limit switch
S and G Constructions
Shree Ram Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .