| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC DINADAYAL ASRAM PARA A D NAGAR AGARTALA TRIPURA WEST PIN 799003 | WEST TRIPURA | TRIPURA | 799003 | ₹4.6 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical COLLEGE TILLA AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | R.P.ELECTRONICS L3 | SWAPAN CHOWHAN L2 | S D COOL TECH L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 1.50 TR (4,500 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge. | 3 | Job | 53,000 ₹1.6 L | 31,000 ₹93,000 | 39,400 ₹1.2 L |
| 2.00 | Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 2.00 TR (6,000 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge. | 6 | Job | 63,000 ₹3.8 L | 30,500 ₹1.8 L | 48,400 ₹2.9 L |
| 3.00 | Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation,clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge. | 9 | Job | 4,000 ₹36,000 | 20,000 ₹1.8 L | 2,000 ₹18,000 |
| 4.00 | Supply and installation of additional length of copper pipe of 5/8'' and 1/4'' diameter or suitable diameter for suction and liquid line in a set and wrapping of copper pipes between indoor and outdoor unit (1.50 TR & 2.00 TR AC) beyond the standard length of pipe as per direction of the Engineer-in-Charge. | 9 | Nos | 1,500 ₹13,500 | 2,500 ₹22,500 | 1,200 ₹10,800 |
| 5.00 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 9 | Nos | 2,500 ₹22,500 | 576 ₹5,184 | 1,200 ₹10,800 |
| 6.00 | Providing hard PVC pipe of good quality of at least 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.. | 54 | Mtr | 200 ₹10,800 | 150 ₹8,100 | 120 ₹6,480 |
| 7.00 | Providing and connecting Electric Control cables between indoor unit and outdoor unit beyond stand quantity kit. 3C X 2.5 Square mm Copper Cable. | 65 | Mtr | 200 ₹13,000 | 102 ₹6,630 | 120 ₹7,800 |
Tender Value
₹6.5 L
EMD Value
₹12,954
Closing Date
29 Nov 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer, Mechanical Division
Providing Installation commissioning of 15 and 2 TR Split type high wall inverter compressor technology Air Conditioning machines at OT unit in the newly constructed Sabroom Sub Divisional Hospital Sabroom South Tripura
2025_CEPWD_67268_1
65_EE_DNIT_MECH_AGT_2526
Open Tender
Electrical Works
30 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹12,954
25 Feb 2026
17 Nov 2025
29 Nov 2025
17 Nov 2025
29 Nov 2025
17 Nov 2025
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: The Executive Engineer, Mechanical Division,PWD, Agartala.
Name of work: Providing, installation and commissioning of 1.5/2.0 TR Split Type High Wall Inverter Compressor Technology Air Conditioning Machines at OT unit in the newly constructed Sabroom Sub-Divisional Hospital, Sabroom, South Tripura.
Contract DNIeT No: 65/EE/DNIeT/MECH.DIVN/AGT/2025-26
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE in/c all taxes & GST In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in/c all taxes & GST in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT in/c all taxes & GST In Words
1 Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 1.50 TR (4,500 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge. 3 Job 0 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
2 Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 2.00 TR (6,000 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge. 6 Job 0 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
3 Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation,clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge. 9 Job 0 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
4 Supply and installation of additional length of copper pipe of 5/8'' and 1/4'' diameter or suitable diameter for suction and liquid line in a set and wrapping of copper pipes between indoor and outdoor unit (1.50 TR & 2.00 TR AC) beyond the standard length of pipe as per direction of the Engineer-in-Charge. 9 Nos 0 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
5 Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. 9 Nos 0 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
6 Providing hard PVC pipe of good quality of at least 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.. 54 Mtr 0 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
7 Providing and connecting Electric Control cables between indoor unit and outdoor unit beyond stand quantity kit. 3C X 2.5 Square mm Copper Cable. 65 Mtr 0 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_68450.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.08 MB
DNIT.pdf
Tender Documents • 3.41 MB
BOQ_68450.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid