Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.4 LAccepted-AOC | L-1 | Accepted-AOC AS PER CWC-II DECISION HELD ON 30/09/2023 | |
| 2 | L-2₹9.4 L+₹98,466 (11.7%)Rejected-AOC 550 HIWARI LAYOUT WARDHAMAN NAGAR NAGPUR MAHARASHTRA 440008 | NAGPUR | MAHARASHTRA | 440008 | L-2 | Rejected-AOC AS PER CWC-II DECISION HELD ON 30/09/2023 | |
| 3 | L-3₹10.2 L+₹1.8 L (21.4%)Rejected-AOC | L-3 | Rejected-AOC AS PER CWC-II DECISION HELD ON 30/09/2023 | |
| 4 | l-4₹12.0 L+₹3.6 L (42.8%)Rejected-AOC | l-4 | Rejected-AOC AS PER CWC-II DECISION HELD ON 30/09/2023 | |
| 5 | L-5₹13.9 L+₹5.6 L (66.2%)Rejected-AOC GODHAR P O KUSUNDA DHANBAD 828116 | DHANBAD | DHANBAD | JHARKHAND | 828116 | L-5 | Rejected-AOC AS PER CWC-II DECISION HELD ON 30/09/2023 |
Tender Value
₹14.7 L
EMD Value
₹29,400
Closing Date
26 Jun 2023, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER
O.F.BHANDARA
Extension of building for installation of automatic Re-work cutting machine at bldg no. R-O7 inside Factory at O. F. Bhandara.
2023_MIL_156712_1
EO/F/51/ND2205/BF
Open Tender
Civil Works - Buildings
Works
180 days
O.F.BHANDARA
As per Tender Documents.
7 documents required · 7 mandatory
₹0
₹29,400
Yes
7 Oct 2023
9 Jun 2023
28 Jun 2023
9 Jun 2023
26 Jun 2023
9 Jun 2023
Amount
Site clearance soft/loose soil.
M & L for grubbing up tree trunk exc. 100 cm and n exc.150cm girth including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50m and clearing site, complete all as specified
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified
Demolition, Cement concrete (unreinforced or reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge.
M & L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified
M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified.
M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC 1:2:4 type B1 using 20mm graded aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC 1:2:4 type B1 using 20mm graded aggregate in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed by the Engineer-in-Charge . .
M & L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L for forming 12mm thick Expansion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, Thickness of concrete slab in 100mm, complete all as specified and as directed by the Engineer-in-Charge .
M & L for finishing surface of concrete roads, pavements, by belting but by brooming, complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L for removing excavated material (soils), exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified & directed by EIC
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel deformed or twisted bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for rendering 20mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces & inished even and smooth without using extra lime or cement complete all as specified and as directed by the Engineer-in-Charge.
M & L for returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by the engineer -in-charge.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-C
M & L for rough cast wired glass 6.4mm thick and glazing with oil putty in square n exc 0.5 sq m complete all as specified and as directed by the Engineer-in-Charge
S & F 1st class hardwood chowkats and frames Plain, solid, straight, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed by the Engineer-in-Charge
S & F 40mm thick, Ist class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with comercial face veneers; fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge
S & F butt hinges 125mm size, type B-11, extruded brass, with mild steel hinge pin, bright polished complete all as specified and as directed by the Engineer-in-Charge
S & F 250mm long brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and as directed by the Engineer-in-Charge
S & F 150mm long brass barrel tower bolts, with barrel of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge
S & F 125mm extruded brass handles, fabricated type polished complete all as specified and as directed by the Engineer-in-Charge
M&L Preparation of new surfaces including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, and efflorescent salts and trading oil, greasy spots and old paint scaling completly and applying coat of primer(birla cem/tata cem or equivalent) & two coats of cement paint on wall/ ceiling. Make of cement paint will be SNOWCEM or equivalent Colour code will be as per direction of EIC.
M&L Preparation of new painted surfaces including knotting and stopping and painting wood and wood based surfaces of any description,not otherwise described over 10 cm width or girth apply one coat of pink primer with two coats of synthetic enamel paint.. Make of synthetic enamel paint will be of premium quality BERGER/ ASIAN/ NEROLAC OR equivalent. Colour code will be as per direction of EIC.
M&L Preparation of new painted surfaces and painting Bricks, stone, concrete, asbestos cemsnt or plaster surfaces of any description over 10 cm width or girth not otherwise described with one coat of alkali resistant Primer plaster coat and two coats of synthetic enamel paint. Make of synthetic enamel paint will be BERGER/ ASIAN/ NEROLAC OR equivalent. Colour code will be as per direction of EIC.
M&L Preparation of new surfaces by applying one coat not exc.3mm thick wall care putty on wall/ceiling. Make Asian cement base putty/ JK white cement base putty/birla wall care putty OR equivalent.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets roof coverings including roof trusses, pulins etc complete .
S & F Rolled seection IS marked as in main and cross beams, hip and jack rafters, purlins, where connected to common rafters and running rails and guides for siding doors,fixed with angle cleats or other connecting plates.
S & F 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts in roofs, walls etc. complete all as specified and as directed by the Engineer-in-Charge
M & L for 6mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed by the Engineer-in-Charge
S & F only of anodised aluminium/GI snap grid frame work for false ceiling complete all as specified and as directed by the Engineer-in-Charge
S & F only of hangers 6 mm dia. G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceillling cleat made out of G.I flat 40*3 mm size 60 mm long complete all as specified and as directed by the Engineer-in-Charge
Taking down bitumen mastic of any thickness and any situation as directed by EIC
M&L for bitumen mastic antistatic flooring 25 mm thic with matt finish in floor perpared and laid as per confirming to IS8374 (1977),IS-1195(2002) and IS 1196 (1978reaffirming 2001)including 320gauge brass strip 25 mm wide laid @300mm C/Cboth way and fixed with brass screw and grits & antistatic testing as per STEC no.7 all as specified and directed by EIC
M&L for 25 mm bitumen mastic to vertical surface of drains /wall in two coats including wired 0.90mm dia ,16mm mesh fixed with tinned tickets or wire stapels at 150mm C/C all as specified
jain transport corporation
Rajesh Gurao
H R LANJEWAR
LAL AND SONS
DARSHAN SINGH PLAHA
Mangla And Mangla Construction
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .