Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹4.9 L+₹2,669.93 (0.55%)Rejected-Finance | L2 | Rejected-Finance Due to higher rate than L1 bidder | |
| 3 | L3₹4.9 L+₹2,912.65 (0.60%)Rejected-Finance | L3 | Rejected-Finance Due to higher rate than L1 bidder | |
| 4 | L3₹4.9 L+₹2,912.65 (0.60%)Rejected-Finance N A | L3 | Rejected-Finance Due to higher rate than L1 bidder | |
| 5 | L3₹4.9 L+₹2,912.65 (0.60%)Rejected-Finance N A | L3 | Rejected-Finance Due to higher rate than L1 bidder |
Tender Value
₹4.9 L
EMD Value
₹9,709
Closing Date
16 Feb 2026, 11:00 amClosed
Assistant Engineer
BIDHANNAGAR WEST SUB DIVISION-III, PURTA BHAVAN, 1ST FLOOR, ROOM NO-122, SALT LAKE, KOLKATA -91
Necessary repairing of damaged Granite at the lift fascia at 2nd floor and Computer cabinet of Room No. 111 at 1st floor along with some other allied works at Purta Bhavan during the year 2025-2026.
2026_WBPWD_999788_5
WBPWD/AE/BNWSD-III/NIT-21e /2025-2026
Open Tender
CIVIL WORKS
Percentage
18 days
Bidhannagar, Salt Lake
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,709
Yes
7 Sept 2026
6 Feb 2026
18 Feb 2026
6 Feb 2026
16 Feb 2026
9 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board etc. of any thickness and refixing same in new position with necessary clamps making holes in walls, floor, roof and mending damages if any.[concrete plaster will be paid separately] | 115.5 | Sq.M. | 55 | ₹6,352.5 |
| 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. | 156.52 | Sq.M. | 19 | ₹2,973.88 |
| 3 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge | 6.22 | Cu.M | 166 | ₹1,033.02 |
| 4 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping]
In Seventh Floor
(iv) 12mm | 30.62 | Sq.M. | 1,723 | ₹52,758.26 |
| 4.01 | (iii) 9mm | 1.6 | Sq.M. | 1,304 | ₹2,083.79 |
| 5 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.
The rate includes the cost of labour, adhesive and all incidental charges
thereof.In ground floor]
Glossy/Matt/Suede excluding surface texture or metallic lustre.
(i) Thickness of laminate 1.5mm | 30.62 | Sq.M. | 816 | ₹24,985.92 |
| 6 | Supplying, fitting and fixing of false ceiling framework with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit all complete as per the drawing & directions of Engineer-in-charge. | 115.5 | Sq.M. | 467 | ₹53,938.5 |
| 7 | A. Exposed False-ceiling Work --
(b) Supplying, fitting & fixing High Pressure steam Cured Non Asbestos Pearl designer fibre cement standard ceiling board (Density > 1500Kg per Cu.m. ) of size595mm X595mm conforming IS 14862 and type A, catagory IV of ISO 8336, tested as per AS-1530 Part 3 and BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a false ceiling all complete as per drawing & direction of Engineer - in- Charge. False ceiling with
(i) 4mm thick Pearl Designer Fibre Cement Standard ceiling board. | 115.5 | Sq.M. | 412 | ₹47,586 |
| 8 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with
admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete.
[Using cement slurry at back side of granite @ 4.4 kg/sq.m &
white cement slurry for joint filling @ 1.8 kg/sq.m]
In Third floor | 6.72 | Sq.M. | 3,212 | ₹21,584.64 |
| 9 | Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings.
In First floor:
(a) 35mm thick shutters (single leaf) | 6.12 | Sq.M. | 3,969 | ₹24,290.28 |
stage.html
html • 0.12 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
2911.pdf
Tender Documents • 1.25 MB
BOQ_2450815.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .