| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.7 LAccepted-AOC MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹42.3 L+₹2.9 L (7.25%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹44.2 L+₹4.7 L (12.0%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45.1 L
EMD Value
₹90,200
Closing Date
22 Nov 2022, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
SPECIAL REPAIRS TO CONTAINER SHED OF WORKSHOP BUILDING NO. P-08 COMPLEX OF TPW INSIDE NAVAL DOCKYARD PROVN OF VIEW CUTTER NEAR MAIN STAGE AT NAVAL OFFICERS INSTITUTE AND LEFT OVER ITEMS OF SPECIAL REPAIRS TO GUARD ROOM (BLDG NO. P-05) 05 NOS WATCH
2022_MES_559752_1
C/8103/22-23/E8 / Token 72 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,200
Yes
14 Dec 2022
25 Oct 2022
24 Nov 2022
25 Oct 2022
22 Nov 2022
8 Nov 2022
Amount
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed
M & L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:4 complete all as specified and directed.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved Bonding Agent / Epoxy Treatment in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed.
S & F 12mm mesh size Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staplescomplete all as specified and directed.
M & L for preparation new external surfaces of wall etc "Vacuum based sandng machine" and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by "Auto Roller" machine complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc after complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm by "Auto Roller" machine complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc by "Vacuum based sandng machine" and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant primer by Auto Roller machine and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment "Vacuum based sandng machine" and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant priming coat by Auto Roller machine over one or more coat of wall care putty complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing, etc, and finished the cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in roof kerb or mud stop, benching etc rounded or chamfered on edges incuding necessary form works etc complete all as specified and directed.
M & L for 40 mm thick, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in sub base of flooring, etc complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing & 15 mm thick, screed bed in cement mortar 1:6 complete all as specified and directed.
M & L for Machine cut kota stone slab, 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing & 10 mm thick, screed bed in cement mortar 1:4 as in vertical surfaces as skirting/dado etc complete all as specified and directed.
M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
S & F in repairs Steel rolling shutters, 1.25mm thickness of lath with out ball bearing, as specified including top cover, an-choring rod, hasp and staple and one shop coat of primer; erected in position as indi-cated, complete: push pull or manual type complete all as specified and directed.
M & L for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
S & F in repairs Aluminium powder coated (minimum 50 micron thick) windows frame with shutters sliding pattern consisting of three tracked frame and 03 shutters (2 shutters glazed and 01 shutter gauge) using standard medium weight section of weight not less than 0.55 Kg/RM including glazing with 4.8 mm thick sheet glass fixed with suitable EPDM rubber beading and one shutter with stainless steel mosquito proof wire cloth of 0.36mm nominal dia wire and average aperture 1.4mm) and aluminium decogrill (DG-102) and necessary handles/locking arrangements for shutter of Jindal (or equivelant) sections Window Frame ( Top & Sides) : 21137, Bottom L 20977, Window shutters : Top & Bottom : 20567, Sides : 20738 and making good disturbed surfaces all as per the existing one complete all as specified and as directed.
S & F in repairs Aluminium powder coated (minimum 50 micron thick) ventilator, half fixed glazing and half openable shutter with side or top hung including necessary operating arrangements , frame size shall be 100mmx42mmx1.55mm thick and shutter size 40mmx18mmx1.55mm thick section and glazed with and including 4.8mm thick sheet glass including necessary jointing, cleats, powder coated glazing clips, snap beading, screw and aluminium fittings, suitable size of handle etc and making good disturbed surfaces all as per the existing one complete all as specified and as directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, shelves etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Dismantling of Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings with ridges complete all as specified and directed.
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 40 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
S & F 125 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 100 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 300mm long, Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated soils exc 250 m but n. exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm including form mould, mitred/stopped etc. complete all as specified and as directed.
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S & F Rolled mild steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched, forming holes, with riveted, bolted or welded attachmentcomplete all as speicfied and directed.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing, etc, and finished the cement concrete surfaces even and fair without using extra cement complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M & L for preparing old decorated surfaces of walls, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. complete all as specified and directed.
M & L for Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 79 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 79 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F Sheet metal enclosure with socket plug top and MCBs having triple pole and nutral enclosure with a three pin and earth plug and socket complete with one triple pole MCB of capacity 32Amp, 415V complete all as specified and as directed.
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch, AC 230V, 50HZ, complete all as specified and as directed.
S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (ii) Four runs of 10 sqmm and two runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
S & F LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 30 Watt, Lumen ≥ 3000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-GRY-LSRT015030XC or equivelant of make as per list of manufacturer)
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F MCCB 415 Volt 16 KA, 3 Pole, 63 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 03 or equivelant of make as per List of Manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 12 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 18 to 20 or equivalent make as per List of Manufacturer's)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs earth continuity conductor or main earthing lead with aluminium strip of size 25x3mm mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
S & F in repairs earth continuity conductor or main earthing lead with galvenised iron strip of size 25x4 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
S & F in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long fixed to overhead reservoir as in lightening protection with necessary connections to earthing etc complete all as specified and directed.
S & F in repairs Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
K SATYANARAYANA ENTERPRISES
M/s VENKATA JAHNAVI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .