Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
16 Dec 2021, 6:00 pmClosed
SHRI T C SHISHODIYA, DCWE (C)
MULTAN LINE ARMY AREA JODHPUR
Repairs To Plinth Protection, Drain Path Culvert and Hardstanding, Fencing RCC Jali and Misc Works in PBOR MD Accn in Army Area Jodhpur
2021_MES_489137_1
CWE (A) JODH-43 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE(Army) Central
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE(Army) Central
₹70,000
27 Dec 2021
18 Nov 2021
17 Dec 2021
18 Nov 2021
16 Dec 2021
2 Dec 2021
Amount
Demolition of cement concrete in ground floors and pavings n. exe 15 cm thickness (below or above ground level) complete all as specified & as directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B1, (using 20mm graded stone aggregate) as in floor including finishing cement concrete surface even and smooth without using extra cement complete all as specified & as directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring, path , foundation etc complete all as specified and directed.
M&L 50mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar places, without using extra cement complete all as specified and directed.
Supply only 38 mm wide 3 mm thick glass dividing strips.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & as directed.
M&L PCC solid building blocks exc 10 cm in width type B1 (1:2:4 ) using 20 mm graded aggregate set in cement mortar (1:6) complete all as specified and directed.
M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 complate all as specified and directed.
All as per item No 8 above but except stone complete all as specified and directed.
Extra over squarred rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete all as specified and directed.
M&L for 5 cm thick sand stone slabs as in chajjas, copings, window cills, etc n.exc 2 m in length punched dressed on exposed faces and self faced on other side and set and pointed in cement mortar 1:4 all as specified and directed.
M & L 20 to 25 mm thick machine cut one side polished granite of approved colour in kitchen plate form, etc set and jointed including 20 mm thick screed bed in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing complete all as specified and directed.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface complete all as specified & directed.
M&L Rendering 10 mm thick CM (1:3) on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth complete
Racking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar all as specified
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 all as specified.
M/L two coat of colour wash on newly plastered/ unplastered surfaces over one coat of white wash on wall & including preparation complete all as specified and directed.
M & L three coats of white wash on newly plastered surface of ciling/facia /rcc including preparation of surfaces complete all as specified and directed..
M & L one coats of white wash on old surface of walls complete all as specified and directed..
M & L one coats of white wash on old ceiling surface complete all as specified and directed..
M & L two coat of cement base paint over a coat of white chalk on wall over a plaster/unplastered surfaces including preparation of surface complete.
M & L applying one coats of synthetic enamel paint on old steel surface of any description over 10 cm width or girth including preparation of surfaces complete.
Demolition of reinforced cement concrete of as staircase, landing, chajjas and similar suspended work of any description and any position not otherwise
Providing precast RCC using 20mm graded aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles set in CM 1:6 complete all as specified and drected.
M&L for TMT bars 6 to 8mm dia and over, cut to length , bent to shape required including cranking, bending & binding with MS wire (annealed ) not less than 0.9mm dia or securing with clips, as in stirrups also & all as specified.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 100 mm bore as directed
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 75mm bore as directed
S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed
S&F 75 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed
S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on wall complete all as specified and directed
S&F 75 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on wall complete all as specified and directed
S&F in repair 100mm CI bends any radius complete all as specified and directed
S&F in repair 75 mm dia CI bend with oval acess door fixed to pipe complete all as specified and directed.
S&F in repair 75 mm dia CI floor trap plain grating including jointing with solvent cement complete all as specified and directed.
S & F in repair Cast iron nahani trap 100 mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggreate complete.
S&F in repair of PVC SWR gully trap 125/110 mm size including setting and jointing with solvent all as specified and directed.
S&F 110 mm PVC SWR pipes single socketd in any length with rubber rings joints laid fixed to wall complete all as specified and directed.
S&F 75 mm PVC SWR pipes single socketed in any length with rubber rings joints fixed to wall complete all as specified and directed.
S&F110 mm PVC (SWR) bends any radius complete all as specified and directed
S&F 75 mm PVC (SWR) bends any radius complete all as specified and directed
Dismantling of RCC fencing post or struts of any description/section including taking out embeded ,barbed wire in concrete and making good disturbed all as directed
Dismantling expanded metal, chain link fencing, barbed wire in carefully any thickness or mesh, fixed with steel or wood fillets, if anyall as directed
Excavation in post holes (or similar holes) each n exc 0.5 cum in soft/loose soil getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm watering and removing surplus soil to a distance n exc 50m and making good surfaces in any type of soli complete all as specified and directed.
S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for round bars 10mm dia and over, cut to length , bent to shape required including cranking, bending & binding with MS wire (annealed ) not less than 0.9mm dia or securing with clips, as in stirrups alsoFE 410-w(Gde, E-250 quality A or Fe 290(Gde-E-165) complete all as specified and directed.
Supply only chain link MS galvanised fencing of size mesh (50 mm x 50 mm/75mm x 75 mm) complete all as specified and directed.
Fixing only chain link MS galvaniced fencing including line wires any mesh size and type to any type of standards, rails straining bolts etc including peovission of binding wire complete all as specified and directed.
S & F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or stel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M&L mild steel bolts machine made 10mm dia of neck hexagonal or square head at one end and screwed the other or screwd both ends each screwed end to be fitted with washers and one hexagonal or square exceeding 5 cm but not exceeding 10 cm long complete all as specified and directed.
M & L chequrred cement concrete tile 25 cm x 25 cm x 22 to 25 mm thick, set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M & L rubberised coloured chequrred tile 25 cm x 25 cm x 22 to 25mm thick/30 cm x 30 cm x 22-25 mm thick, set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Providing and laying (interlocking paver)60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand.
Providing and laying (rubberised interlocking paver)60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
S&F machine made precast cement concrete Kerb stone blocks using cement concrete 1:3:6 type C2 using 20mm graded stone aggregate all as directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal and wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
M&L 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane
S/F of 4mm thick pinheaded sheet glass panes of size not. exceeding 0.5 Sqm fixed with oil putty
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.0mm as in repair.
M&L for repair to any size window including taking down replacement of unserviceable hinges device box type handle making them serviceable condition and refixing on same opening making the soffit and jamb good condition as per directon of Engineer -in -Charge .
Taking down bush/vegetation in roof side, wall and any position in the existing bldg complete portion removing the all root on wall complete with the satisfication of Engr in charge and after removing the root the whole area of spray the acid in the and making good distrubed area with PCC/Plastering etc complete all as specified and directed.
Dismantling structural steel work including doors, gates etc complete all as specified and directed.
M&L for framed work using MS angle iron , rectangular hollow sections. solid square bars , fat iron, MS Channel sections , or hollow structural tubes etc incl necessary cutting & bending to shape & welding together complete as in cooler stand, gates, cattle traps, overhead trusses, railings etc complete all as per the design & patterns complete all as specified and directed.
Dismantling of asbestos cement/GI// PVC ( corrugated , semicorrugated , etc ) sheet in roof covering.
Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
S & F 2mm thick fiber glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof , wall etc.
S & F framed work such as grills, grating, etc. with ends of bar shoulder and/or riveted, or forged into spikes, framed guard bar complete.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching to drain, coping, etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and as directed.
M & L providing 35 mm thick pre-cast cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in louvers & jallies (measured solid) including all mouldings and including pre-cast frames set in cement mortar 1:4 complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
M & L cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for 150 mm dia pipe complete all as specified and directed.
Supply , laying jointing and testing 150mm bore reinfirced conctete pipes class NP-2 laid and jointed in cement mortor 1:1 complete with collars or socket/spigot type laid jointed and haunching at side in cement complete all as specified and directed. (Note- cement concrete used for haunching concrete shall be measured and paid seperately)
Cleaning and removing all scale and dirt etc from over head water tanks and from mouths of circulating pipe etc including dismantling & refixing at same or other place of capacity exc 250 ltrs but n exc 500 ltrs complete all as specified and directed by Engr-in- Charge. Note :- Accessories including replaced the float valve trede nipple , gate valve if damaged during the cleaning of tank shall be replaced by the contractor at his own arrangement and will not be paid by the department.
Demolition of existing water proofing Treatment including PCC padding etc and cleaning roof surface etc preparing the surface to receive plaster /PCC by brushing with wire brush and fanning the surface to remove all loose dirt etc .
Material and labour for providing cement concrete (1:2:4) type BO using 12.5mm graded crushed stone aggregate as over roof for making good depression/undulation to make the existing as filling in depression of roof slab complete all as specified and directed.
M&L for PCC 1 : 2 : 4 type B0 using 12.5 mm graded stone aggregate as in roof kerb including weathering, slightly rounded or chamfered angles and throating, as directed etc
M& L for roof treatment in the following stages :- (a) first Course : M&L for 10 mm thick plaster with CM 1:3 mixed with water proofing compound as per manufacturee instructions (Note: - WPC shall be measured and paid separately) (b) Second Course : One coat of bitumen primer T-10/polymerised confirming to IS 3384 @ 0.30 ltr/Sqm (c) Third Course : One coat of Bininding material using blown type bitumen conforming to IS 702 grade 85/25 @ 1.20 Kg/Sqm (d) Fourth Course : A layer of APP membrane polymeric membrane centre core of 100 micron HMHDPE outer film 20 micron each, thickness 2 mm having weigh 3.00Kg/Sqm (e) Fifth Course : A coat of bonding materail using blown type bitumn conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm (f) Sixth Course :40mm thick PCC 1:2:4 padding, well compacted using 20 mm graded aggreegatel with groovs shall not be exceeding 1.40 Sqm
m/s Firoz khan
Jai Doulat Construction Co
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .