Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.8 L+₹2.0 L (5.30%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹40.1 L+₹3.3 L (8.88%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | - | Rejected-Technical Not enlisted in b(i) b(ii) | |
| 5 | Rejected-Technical KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | - | Rejected-Technical Not enlisted in b(ii) |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
26 Dec 2023, 6:00 pmClosed
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
REPAIR MAINT OF HT VCBS RMU CSS INTERNAL EXTERNAL ELECTRIC SUPPLY STREET LIGHTS POLES GARDEN LIGHTS AND MISC ITEMS AT DHQ-01 CG JETTY ICGRA DHARMAPUR UNDER GE(I) CG PORBANDAR
2023_MES_630762_1
8951/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
PORBANDAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹74,000
Yes
7 Feb 2024
2 Dec 2023
28 Dec 2023
2 Dec 2023
26 Dec 2023
19 Dec 2023
Amount
SCHEDULE 'A' E/M ITEMS
Material and labour for painting of the tranformer 250 KVA to 630 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., Complete all as specified & directed by Engineer-in-Charge.
Taking out UNSV HT UG cables of any sizes from trenches, Complete all as specified & directed by Engineer-in-Charge.
Supply, Laying, connecting, testing and commissioning and jointing, HT under ground cable of size 120 Sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in renches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, Complete all as specified & directed by Engineer-in-Charge. Make Polycab/Havells/ RR Kabel
Supply, Laying, connecting, testing and commissioning and jointing, HT under ground cable of size 185 Sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in renches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, Complete all as specified & directed by Engineer-in-Charge. Make Polycab/Havells/ RR Kabel
Supply & fixing Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, Complete all as specified & directed by Engineer-in-Charge. Make-Denson/Raychem/3M
Supply & fixing Cable jointing kit for 11 KV (Earthed) grade cable for Indoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, Complete all as specified & directed by Engineer-in-Charge. Make-Denson/Raychem/3M
Supply & fixing Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, Complete all as specified & directed by Engineer-in-Charge. Make-Denson/Raychem/3M
Material & Labour for Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, Complete all as specified & directed by Engineer-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Supply and Fixing in replacement air break switch triple pole, 11KV, mechanically operated mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete with including insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceble air break switch, jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated, Complete all as specified & directed by Engineer-in-Charge. Make: Jaipuria/ Atlas/Pactil
Supply & fixing in replacement HT 11 KV drop out fuse assembly with insulator and base including fuse tube, fuse carrier top connectors incomming and out going connectors, Complete all as specified & directed by Engineer-in-Charge. (Note: Rate include taking down existing unserviceble/ Faulty DO fuse assembly and fix the new one and make the incomming and out going connections and switch on the supply through the new DO fuse assembly all as directed by EIC) Make: Jaipuria/ Atlas/Pactil
Preventive Maintenance and Servicing, 11/0.433 KV Step down Transformer Indoor and Oil Cooled type by disconnecting carefully electric connection on primary & secondary side, Checking both side HT bushing, bushing rod, opening top cover of the transformer by unscrewing nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any from the entire body of the transformer, during servicing and re-fixing the top cover of transformer according to previous system. Servicing of the transformer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each transformer to the Engr-in-Charge. Note 1. :- Inspection of transformer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints. (c) Checking all terminations / connections inside/ouside the transformer. (d) Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding. (e) Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge. Note 2. : Spares used bushes studs HT/LT, bushing rod HT/LT, transformer oil, filteration of oil, buchholtz relay, Gaskets set, Off Load Change over switch etc will be measured and paid separately under respective item of BOQ. Note 3 :- The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement. Locations ICGRA Dharampur
250 to 630 KVA
RMU/CSS
Material & Labour for Maintenance/Over hauling of RMU (1 No incoming, 2 No’s outgoing) of outdoor type no extensible 11 KV, SF6 insulated compact ring main unit (RMU) with short circuit peak making current 50 KA and short circuit breaking current 20 KA fully arc proof metal enclosed free standing floor mounting manually operated fixed type SF6 insulated, 2 Nos. Load break switches 400 Amps (as incoming) and 1 No SF6 circuit breaker 200 Amps (as outgoing), by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT RMU by employing the Skilled trades man and helper, Complete all as specified & directed by Engineer-in-Charge. Note: Rate Include following:- (i) Replacement of Mechanical indication in the front in the mimic for open & close breaker/isolator/ earth switch and Manual push button for emergency trip etc., all as specified and as directed by Engineer - In - Charge. (ii) Disconnect the HT cables in Test position, Check the megger value of RMU terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of earthing connection by Earth megger note down the readings.
Material & Labour for Maintenance/Over hauling of Compact Substation outdoor type (CSS), 630 kVA Transformer, 11kV Ring Main Unit consisting of 2 Nos (01 No In Cmg & 02 Nos Out Going) & 630A at 11kV fault making load breaking switch with one no SF6 insulated Vacuum Circuit Breaker & with LT Panel comprising of 1000 Amp ACB as secondary side, by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT RMU by employing the Skilled trades man and helper, Complete all as specified & directed by Engineer-in-Charge. Note: Rate Include following :- (i) Replacement of Mechanical indication in the front in the mimic for open & close breaker/isolator/ earth switch and Manual push button for emergency trip etc., all as specified and as directed by Engineer - In - Charge. (ii) Replacement of Digital volt meter, Amp Meter, Power factor meter and CT of Ratio 1000/5 for RYB Phase in LT Panel
Material & Labour for Maintenance/Over hauling of HT VCB 11 KV (1 No incoming, 3 Nos outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightning the control circuit, Checking the all fuses, to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helperm, Complete all as specified & directed by Engineer-in-Charge. Note: Rate Include following:- (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unseviceble indicator lamps asper colour code all as specified and as directed by Engineer - In - Charge. (ii) Rack out /Down the HT VCB kept in Test position, Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the servicebility of earthing connection by Earth megger note down the readings.
Supply and fixing in replacement of closing coil 24 Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model and directed at site, Complete all as specified & directed by Engineer-in-Charge.
Supply and fixing in replacement of vaccum bottle suitable for 11 KV VCB, 400 Amps as per existing make and model and directed at site, Complete all as specified & directed by Engineer-in-Charge.
Supply and Fixing in replacement of indiaction LED lights for each phase of 230 Volt, Complete all as specified & directed by Engineer-in-Charge.
Supply and Fixing in replacement of Multifunction Meters (MFM) suitable for 11 KV VCB 400 Amps as per existing make and model and directed at site, Complete all as specified & directed by Engineer-in-Charge.
Supply & fixing in replacement Silica Gel (Moisture absorbent chemical) for breather of transformer 11 KV /433 Volt of any make / rating, Complete all as specified & directed by Engineer-in-Charge. Locations ICGAE/ICGRA D.Pur
Supply & fixing in replacement oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt, Complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, Complete all as specified & directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25 cm thick , Complete all as specified & directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, Complete all as specified & directed by Engineer-in-Charge.
Laying only un-reinforced precast concrete cable cover class HV, type-I, flat size 300mm x 180mm x 40mm laid cable cover to be reused, Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for cutting existing road/hard standing not exceeding 45cm x 45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10cm from top using PCC 1:2:4; including removal of surplase soil, Complete all as specified & directed by Engineer-in-Charge.
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, Complete all as specified & directed by Engineer-in-Charge. Note: Defective parts if any will be measured and paid seprately.
Supply and fixing in replacement of heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified & directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fixing in replacement of heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified & directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fixing in replacement of heavy duty gas filled Capacitor 15 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified & directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fixing in replacement of heavy duty gas filled Capacitor 20 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified & directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fixing in replacement of heavy duty gas filled Capacitor 25 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified & directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fixing in replacement of 6 Steps APFC Relay, microprocessor based and connected items, Complete all as specified & directed by Engineer-in-Charge. Make: L&T/Epcos/Schneider/C&S
Material & Labour for applying two coat of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubing of dust etc and apply one coat of epoxy based primer before painting, Complete all as specified & directed by Engineer-in-Charge. Note: Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position deemed to be included in unit rate.
Supply and fixing in replacement Digital time switches (SST 15 min) for street light 215 V single Phase, Complete all as specified & directed by Engineer-in-Charge. Make :L&T/Havells
Material & Labour for preparation of old painted surfaces of Steel Tubular pole upto 9 Mtr long by scarping old paint and applying Single coat of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and Blue stripes each 30 cm (5 Strips) apart up to 1.5 Mtr height and including one coat white distempering for pole foundation above ground level shall deemed to be included in the quoted rate etc., Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor, Complete all as specified & directed by Engineer-in-Charge. cable of following sizes:- Make-Denson/Raychem/3M
25 Sqmm to 50 Sqmm
70 Sqmm to 120 Sqmm
150 Sqmm to 185 Sqmm
240 Sqmm to 300 Sqmm
Taking out UNSV LT UG cables of any sizes from trenches, Complete all as specified & directed by Engineer-in-Charge.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area, Complete all as specified & directed by Engineer-in-Charge. cable of following sizes:- Make: Polycab/ Havells/RR Kabel
16 Sqmm 4 Core
25 Sqmm 4 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
95 Sqmm 3.5 Core
150 Sqmm 3.5 Core
185 Sqmm 3.5 Core
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories, Complete all as specified & directed by Engineer-in-Charge. pipe of following size:- Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate. Make: Rex/Poly/Geminie
Dismantling and taking down the existing defective street light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 Core 1.5 Sqmm size multistranded copper conductor including taking down old unsv 3 Core 1.5 Sqmm size copper conductor, Complete all as specified & directed by Engineer-in-Charge. Note:- 1.5 Sqmm 3 core size multi-stranded copper conductor etc. will be measured and paid separately.
Supply & fixing in replacement street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit etc., and taking down old unsv any size/watt of security light, Complete all as specified & directed by Engineer-in-Charge. Make:-Wipro /Bajaj/Philips
Annual Comprehensive maintenance, servicing and testing of Split type air conditioners of capacity 1.5 ton/2.0 tr of any make complete by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing, oiling, greasing of blower motor, checking and removing any vibration and leakage ensure cutting of compressor / heater in case of failure of blower motor, Gas charging and testing after fixing at site, Complete all as specified & directed by Engineer-in-Charge. Note: (a) Cost of any minor nature repair / items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc. and labour required for removing / refixing including transportation of equipment and repair of PCB is deemed to be included in the unit rate of this items.
Supply and fixing in repair u/s hermetic sealed rotary compressor with new compressor capacity not less than 19000 BTU/hr single phase, including gas charging in the system, Complete all as specified & directed by Engineer-in-Charge. Make : Tecumseh/Toshiba
Supply and fixing in repair u/s hermetic sealed rotary compressor with new compressor capacity not less than 24000 BTU/hr single phase, including gas charging in the system, Complete all as specified & directed by Engineer-in-Charge. Make : Tecumseh/Toshiba
Material & Labour for rewinding of blower motor or condenser fan motor, replacement of wornout bushes, complete of split type air conditioner, Complete all as specified & directed by Engineer-in-Charge. Note: Cutting of wornout wiring deemed to be included in unit rate
Supply and fixing hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, Complete all as specified & directed by Engineer-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor, rewinding electric motor, single phase 230 Volts of water cooler 40 ltrs/Hrs with super enameled copper wire of same gauge, Complete all as specified & directed by Engineer-in-Charge.
Supply and fixing relay for water cooler of capacity 40/80 ltr/hrs, Complete all as specified & directed by Engineer-in-Charge. Make:- Renetor/ Shriram /Dunfoss.
Supply and fixing Thermostat for water cooler capacity 40/80 ltr/hrs, Complete all as specified & directed by Engineer-in-Charge. Make:-Renetor / shriram / Godraj / Danfoss
Supply and fixing PVC Float valve with epoxy coated aluminium arm, with PVC polythene ball suitable for water coolers, Complete all as specified & directed by Engineer-in-Charge.
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc., Complete all as specified & directed by Engineer-in-Charge.
Material & Labour for point wiring with PVC insulated and unsheathed cable 1.5 Sqmm (Nominal area) ISI marked stranded copper conductor single core in existing conduit including 1.5 Sqmm PVC insulated and unsheathed stranded copper cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase-Red, Neutral- Black and Earth- Green complete all as specified and as directed by Engineer-in-Charge for the following. Make of wire: Finolex/RR Cables/Havells
One light/fan point controlled by one, one way switch
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
Material & Labour for point wiring complete with stranded copper conductor 2.5 Sqmm single core (nominal area) PVC insulated and unsheathed cable 1100 volts grade drawn in existing conduit including single core stranded copper conductor connected PVC unsheathed cable 2.5 Sqmm as earth wire to the common earth and connecting to earth dolly all as specified for one 6 pin socket outlet two in one 16/6 amps on an independent board, complete all as specified and directed by Engineer-in-Charge. Make of wire : Finolex/RR Cables/Havells/KEI/Polycab.
Material & Labour for Submain wiring with two single core 2 x 2.5 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 1 x 2.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete including taking down of worn old wiring, complete all as specified and directed by Engineer-in-Charge. Make: RR cables/Finolex/Havells/KEI/Polycab.
Material & Labour for Submain wiring with two single core 2 x 4.0 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 1 x 4.0 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete including taking down of worn old , complete all as specified and directed by Engineer-in-Charge. Make: RR cables/Finolex/Havells/ KEI/Polycab.
Supply & fixing in replacement Casing and caping size 25mm X 16mm, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement uPVC conduit of size 25mm, FRLS, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement corrugated flexible pipe size 25mm, complete all as specified and directed by Engineer-in-Charge.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ, complete all as specified and directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately.
Supply & fixing spare parts for Geyser:-
Heating element 1.5 KW with rubber gasket . Make-bajaj Model Caldia
Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Indication lamp red and green suitable for geyser as required
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro / Bajaj/Philips
Supply & fixing in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro / Bajaj/Philips
Supply and fixing in replacement following items for maintenance of Internal Electrification , complete all as specified and directed by Engineer-in-Charge.
Piano switch, flush type 5 Amps, 1 way.
Piano switch, flush type 5 Amps, 2 way.
Bell push, flush type 5 Amp.
Electric bell Ding Dong type , 230 Volts Single pole.
Socket Outlet 2 in 1, 3 pin, 6A
Switch socket combination, 6 Amps flush type.
Switch socket combination, 16 Amps flush type.
2.5 mfd Capacitor
Stepped type electronic fan regulator
Supply & fixing Modular switch 6/10 A, 1 way, 1 Module (ISI Marked),complete all as specified and directed by Engineer-in-Charge. Make: Legrand/ Schneider/Anchor
Supply & fixing Modular switch 16 A, 1 way, 1 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make: Legrand/ Schneider/Anchor
Supply & fixing Modular socket 6/16 A, 2/3 pin combined, 2 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make: Legrand/ Schneider/Anchor
Supply & fixing Modular socket 6 A, 2/3 pin combined, 2 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make: Legrand/ Schneider/Anchor
Supply & fixing Modular Fan regulator 120W, 2 module (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make: Legrand/ Schneider/Anchor
Supply & fixing in repair metal box 3 module including frame and plate, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair metal box 6 module including frame and plate, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Multi standard Copper Conductor cable of size 1.5 Sqmm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc., complete all as specified and directed by Engineer-in-Charge. Make :- Polycab/Plaza/Havells/ RR Kabel
Supply and fixing in repair power contactor MNX - A1,/MCX-22/MCX-13, 50 Hz, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair power Relay MNX - A1,/MNX - A2, 50 Hz, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in Replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engineer-in-Charge. Make:Wipro / Bajaj/Philips
Supply & fixing in Replacement of LED flood lights 50W, aluminium die cast housing with purity lense for facade lightning with glare free light distrubition enhancing accent lighting, including fixing arrangements etc., complete all as specified and directed by Engineer-in-Charge. Make : Wipro / Philips/Bajaj
Supply & Fixing in Replacement of LED Bollard 11W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, 50 Hz, pole mounted, including PCC 1:2:4 type B1 (20 mm graded aggregate) base of size 300mm x 300mm and depth 600mm for fixing of Bollard with nuts bolts etc., required as per site, complete all as specified and directed by Engineer-in-Charge. Make : Wirpo / Philips/CG/Bajaj Note: Apply for single coat of suitable colour distempering for bollard foundation shall deemed to be included in the quoted rate.
Supply & fixing in Replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted, including PCC 1:2:4 type, base of size 300mm x 300mm and depth 500mm for fixing of Bollard with nuts bolts etc required as per site, complete all as specified and directed by Engineer-in-Charge. Make : Crompton / Bajaj/Wipro/Philips
Supply & fixing in Replacement of automatic street light switch (5 KW to 8 KW) Amps rating 20 Amps NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16/10 sqmm copper shall be suitable, complete all as specified and directed by Engineer-in-Charge. Make :- Healer /Havells /L&T
Supply & fixing in Replacement of On-Load Changeover Switch with encloser 100 Amps, 4 Pole, 415 Volt with cable entry, connecting the cables with proper lugs and glands, complete all as specified and directed by Engineer-in-Charge. Make: Indo Asian/Standard/Havells
Supply & fixing in replacement of Pole box with 6 Amps MCB provision and suitable connector for single hose connections loop in and out 10 to 16 Sqmm 4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, internally embedded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm ), fixing arrangement and clamps including making connections, complete all as specified and directed by Engineer-in-Charge. Make : Hensel / Sintex)
Supply and fixing in replacement MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cabes with proper lugs and glands complete all as specified and directed by Engineer-in-Charge. of following:- Make: Havells/ L&T / ABB /Schneider
MCCB 63/100 Amp FP, 415 V breaking capacity 27 KA
MCCB 200 Amp FP, 415 V breaking capacity 25 KA
MCCB 250 Amp FP, 415 V breaking capacity 36 KA
MCCB 320 Amp FP, 415 V breaking capacity 36 KA
MCCB 400 Amp FP, 415 V breaking capacity 36 KA
MCCB 630 Amp FP, 415 V breaking capacity 50 KA
MCB 40 Amps FP, 415 V breaking capacity 10 KA
MCB 63 Amps FP, 415 V breaking capacity 10 KA
MCB 6 to 32 Amps SP, 240 V breaking capacity 10 KA
SURESH ELECTRICALS
RAJ ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .