| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC As Per Financial Evaluation |
| 2 | L2₹1.5 Cr+₹2.2 L (1.47%)Rejected-AOC | ₹1.5 Cr+₹2.2 L (1.47%) | L2 | Rejected-AOC As Per Financial Evaluation |
| 3 | L3₹1.5 Cr+₹3.9 L (2.62%)Rejected-AOC | ₹1.5 Cr+₹3.9 L (2.62%) | L3 | Rejected-AOC As Per Financial Evaluation |
Tender Value
₹1.5 Cr
EMD Value
₹4.5 L
Closing Date
28 Jan 2023, 2:00 pmClosed
EO Nagar Palika
Nagar Pallika Parishad Mussoorie
Tender For Construction of Building Work Karmchari House Nagar Palika Mussoorie Ward No 03
2023_NPPM1_53738_1
2655/2022-23
Open Tender
Civil Works
Item Wise
240 days
Nagar Pallika Parishad Mussoorie
Please refer Tender documents.
2 documents required · 2 mandatory
₹17,700
EO Nagar Palika
₹4.5 L
6 Nov 2023
7 Jan 2023
28 Jan 2023
7 Jan 2023
28 Jan 2023
7 Jan 2023
15.3 Demolishing R.C.C work manually/ by medchanical means including stacking of steel bars and disposal of unservice material within 50 metres lead as per direction of Engineer-in-charge
15.3 Demolishing R.C.C work manually/ by medchanical means including stacking of steel bars and disposal of unservice material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar
15.25 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
15.9 Demolishing stone rubble masonry manually/ by mechaical meansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge 15.9.2 In cement mortar
15.23 Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead 15.23.1 For thickness of tiles 10 mm to 25 mm
15.13 taking outn doors, windows and clerestory window shutters(steel or wood) including stacking within 50 metres lead 15.3.2 of area beyond 3 sq. metres
2.6 Earth work in excavation by mechanical means(Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kind of soil
Disposal , Dismantling & excavated materail (M.R)
4. providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level:4.1.8 1:4:8(1 Cement:4 coarse sand(zone-III) :8 graded stone aggregate 40 mm nominal size)
5.2 Reinforced cement concrete work in walls(any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piears, abutments, posts and struts etc. above plinth level up to floor five level, excluding coast of centering, shuttering , finishing and reinforcement: 5.2.2 1:1:2 ( 1 cement: 1.5 coarse sand(zone-III): 3 graded stoneaggregate 20 mm nominal size)
5.15 Providing, hoisting and fixing above plinth level up to floor five level precastreinforced cement concrete in lintels, beams and bressumers, includingsetting in cement mortar 13:3( 1 cement :3 coarse sand), cost of requiredcentering and shuttering but excluding the cost of reinforcement, with 1:1:2( 1 cement :1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
5.9 centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc for mass concrete
5.9.6 Columns, pillars, piears Abutments, posts and structs
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes(weepholes)
5.22 Steel reinforcement for R.C.C work including staightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
6.4 Brick work with common burnt clay F.P.S(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :6.4.2 Cement mortar 1:6(1 cement: 6 coarse sand)
12 mm cement plaster of mix 1:6( 1 cement: 6 fine sand)(13.1.2)DSR-
7.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12( 1 Cement: 6 Coarses and 12 graded stone aggregate 20 mm nominal size) upto plinth level with: 7.1.1 Cement mortar 1:6( 1cement: 6 coarse sand)
10.25 Steel work welded in buils up sections/ framed work , including cutting, hoisting, fixing in position and applying a priming coat of approved ateelprimer using structural steel etc. as required. 10.25.2 In gratings, frames, guuard bar, ladder, railings, brackets, gatesand similar work.
12.1 providing corrugated G.S sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I limpet washers or with G.I limpet washers filled with white lead, including a coat of approved steel primer two coat of approved paint on overlapping of sheets primer and two coats of approved paint on overlapping of sheets complete( up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m2
9.20 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board constuction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 9.20.1 35 mm thick including ISI marked Stainless steel butt hinges with necessary screws.
11.41 Providing and laying vittified floor tiles in different sizes(thickness to be specified by the manufacturer ) with water absorption less than 0.88% and conforming to IS: 14622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 ( 1 cement:4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete 11.41.3 size of Tile 800X800 mm
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
13.41 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :13.41.1 New work (two or more coats) over and including waterthinable priming coat with cement primer
13.61 Paniting with synthetic enemal paint of approved brand and manufacture to give an even shade: 13.61.1 Two or more coats on new work
13.48 Finishing with Delux Multi surface paint system for interiors and exteriors usning Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 lir/10sqm over an under coat of primer applied @ 0.80 lrt/10sqm of approved brand and manufacture.
4.1 Providing and laying in position cement concret of specified grade execuding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size)
12.31 Providing 10 mm thick of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25X6 mm with 10 mm gap in between and reinforced with rabbit with mash fixed to wooden frame (frame work to be paid separately) : 12.31.1 Flat surfaces
9.3 Providing wood work in frames of false ceiling, partitions etc. swan and fixed in position with nessary stainless steel screws etc. 9.3.1 Sal wood
Sanitary Fittings 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10liter low level white P.V.C. Flushing cistern, including flush pipe, with manually controlled addevice (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever reqired :17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580X440 mm with integral type food rests
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device ( hendle lever), conforming to IS :7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white soild plastic seat and lid
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :17.7.2 White Vitreous China Wash basin size 630X450 mm with s single 15 mm C.P. brass pillar tap
Providing & fixing of 15mm G.I . Class , 'B' Pipe (Jindal hissar Make) complete with G.I. fitting & materials, labour and T&P etc. and including making good the wall etc. (internal work) as per D.s.r. code no. 18.12.1 15 mm dia nominal bore
18.12.2 20 mm dia nominal bore
17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including pinting the fittings and brackets, cutting and making good the walls wherever required: 17.9.1 White glazed fire clay kitchen sink of size 600X450X250 mm
18.48 providing and placing on terrace (at all floor levels) polyethyiene water stroge tank, IS :12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :18.18.2 20 mm nominal bore
18.16 Providing and fixing brass stop cock of approved quality 18.16.2 20 mm nominal bore
1818.21 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.21.2 45 cm length 18.21.2.1 15 mm nominal bore
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :18.49.1 15 mm nominal bore
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:893118.53.1 15mm nominal bore
18.58 Providing and fixing PTMT grating of approved quality and colour. 18.58.1 Circular type 18.58.1.1 100 mm nominal dia
18.37 Constructing masonary Chamber 60X45X50 mm inside, in brick workin cement moryar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400X200X200 mm (inside) with locking arrangement and RCC top slab 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation contrete 1:5:10 (1 cement : 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :18.37.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
8.1 Mrble work gang saw cut (polished and machine cut) of thickness 10 mm for wall lining (venner work), backing filled with a grout of average 12 mm thick in cement mortar 1:3( 1 cment : 3 coarse sand), includingpointing with white cement mortar 1:2(1 white cement: 2marble dust) with an admixture of pigment to match the marble shade( To be securedto the backing by means of cramps, which shall be paid for separately8.1.1 Raj Nagarplain white marble/Udaipur green marble/Zebra black marble. 8.1.1.1 Area of slab upto 0.50 sqm
Item Drainage 12.41 Providing and fixing on wall face unplasticcised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.1 75 mm diameter
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipe 12.41.2 110 mm diameter
Item Electrical Fittings Wiring point light with 1.50 Sq. mm PVC insulated single core cable in HD PVC condute pipe surface complete with 1.50 Sq. mm PVC insulated Aluminium conductor cable as earth continuity wire drawn inside the conduit complete in all respect. (M. R) Light. Rate
Tube Light. / led light
Fan with Box. Rate/ Exest Fan
Plug Point Box.
S/F of Fan Hook Fabric.
MCB Box
C S RAWAT
dhanpal rawat
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .