| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PALAKKAD | PALAKKAD | KERALA | 678001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 24 234 2 NEAR VYDHYUTHI BHAVAN KOTTAPPURAM ROAD PUNKUNNAM THRISSUR KERALA 680002 | THRISSUR | KERALA | 680002 | Admitted-Finance |
| 4 | Admitted-Finance SMT BHAVANA JOCKIAM ANAPAR D O NEYYATTINKARA TRIVANDRUM | TRIVANDRUM | KERALA | Admitted-Finance |
Tender Value
₹21.3 L
EMD Value
₹50,000
Closing Date
11 Feb 2022, 6:00 pmClosed
Manager Subcontract
KEL Kochi
Construction Of Park and Pathway Surrounding Plakkottu Pond at Panmana Grama Panchayath Under MLA SDF in Chavara LAC
2022_KEL_471631_1
KRO/ BDC/1023/2022
Open Tender
Miscellaneous Works
Item Rate
45 days
KEL Kochi
As per NIT
6 documents required · 6 mandatory
₹2,950
Yes
₹50,000
Yes
18 Feb 2022
1 Feb 2022
14 Feb 2022
1 Feb 2022
11 Feb 2022
1 Feb 2022
1 Feb 2022 - 11 Feb 2022
Amount
Lighting:
Supply conveyance installation testing & commissioning of Pre Fabricated 4 Mtr Decorative pole with single and double arm bracket of 0.50 mtr length Bottom 100 mm dia Top dia 50mm 3.mm thickness with standard arm cap. The pole shall be mounted on suitable foundation (design will provide) loop in loop out terminals block required dia pvc pipe shall be provided in the foundation for taking cable in & out from the pole 3 core 1.5 sq mm unarmored pvc insulated round copper cable from loop in loop out to light fixture and Junction box etc as required.
Supply , conveyance installation testing and commissioning of 45 w single piece Led light fittings suitable for roadway installation with pressure die cast aluminium Housing with corrosion resistance Lamp efficiency more than 90 Lm/w wide beam angle of led and desired spread using reflection and high quality lense over voltage protection up to 300 volt, with natural cooling system, surge protection 4 kv internal with IP 66 protection, horizontal pole mounting bracket with all connected accessories, fixing in existing arm and giving connection with 1.5sq mm 3 core pvc insulated sheathed copper conductor etc
Supply and laying 1.5 sqmm 3 core copper flexible cable Conductor for above luminaries
Supply and installation of 5 to 32 Amps Single pole C curve Minute Circuit Breaker
Fabrication supply & installation of dust vermin proof wall/ floor mounting meter cubicle construction made from thermo plastic as per approved design necessary ti fix KSEB meters fuse unit providing necessary cut-outs for mounting meters, relays,etc.
Supply and fixing 25 a 2 pole ac 1 rated power contractor 25 A connector Digital timer Suitable copper socket 2.5 sqm (ISI) marked FRLS PVC insulated single core copper conductor 1.5 sqm IsI marjedc FRLS PVC insulated single core copper conductor cable
Supply and installation of double pole 25/40 A Residual current circuit breaker having sensitively current up to 300 milli amps
Supply and fixing 240v 40 A Double pole isolator
Supply and provide pipe earthing as per is 3043 with 2 mtr long 40 mm dia b class GI pipe GI funnel with weld mesh, with charcoal including construction of inspection chamber with bed concrete of 1:4:8 pcc using 40 mm broken stone (10 mm thick) brick work in cement mortar 1:6 plastering surface of brick masonry and the exposed surface of pcc bed with cement mortar 1:4:12 mm thick( the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint earth continuity conductor to the plate at the covering at the top
Supply and fixing HRC fuse base of 20/32 A used suitable nut bolt 32 2 way neutral links mounted on smc base and 2.5 sqmm marked FRLS pvc insulated single core copper conductor cable
Supply and laying bare Earthing with 3.15 mm 10 Sw GI Wire Laid 0.6 below ground level including excavating trench of suitable size and refilling etc as required
Supply & laying of one number pvc insulated and pvc sheathed armoured aluminium power cable 1.1 kv grade 3 core 10sq mm in the existing dwc pipe
Supplying laying and jointing 50/38 mm DWc pipe made out of HDPE conforming to is 14930 part II for all mechanical protection to underground power cables with all required accessories in existing trench
Earth work excavation by mechanical means (Hydrylic/Excavator manual means over areas e(exceeding 30 cm in depth 1.5 m in width as well as 10 sqm on plan)including dispose !of excavated earth lead upto 50 m and lift upto 1.5 m disposed earth to be leveled and neatly dressed all kind of soil
Providing and laying in position cement concrete of specified grade exclud ing the cost of centering and shuttering all work up to plinth level 1:4:8(cement '.4 course sand:graded stone 40 m m normal size)
Centering and shuttering including strutting .etc and removal of form work for foundation ,footting bases of s;olmns etc for mass concrete (First footing 38.640,pedestal 212.520.add extra 0.60)
Steel reinforcement for RCC work including straighting cutting bending placing in position and binding all complete upto plinth level thermo -mechanically treated bars of grade Fe 500D or more
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1T5:3(1cement T5 course sand :3 graded stone 20 m m norm el size)
charges for kseb connection including all laison work
fabrication supply conveyance and installation of granite name board indicating all details
FM Radio
Supply and installation of PA Power Amplifier power output 300w max, 250w RMS at 10% THD,220 w RMS at 5 % THD , Output Regulation <_2 dB no load to full load at 1 kKz, input channels 1 X Lins 200mV/100kΏ, Frequency Response 5-15000Hz +_3db, Signal to Noise Ratio, 60 dB, Tone controls Bass:+_10dB at 100Hz, Treble :+_10dB at 10 L kHz, Speaker Outputs,:4Ώ,8Ώ, 70v& 100v, power Supply: Ac 200-240v 50/60Hz Dc:24(2x12v), Power Consumption : Ac:500VA DC:6A and etc required
Supply and Installation Rugged and stable construction, floor mountable Garden speaker: Fitted with two nos of wide response and water resistance polypropylene cone speaker, input power 40W RMS, Power Taps on 100v @ 40/20/10/5 w speaker 2x5” full range, Impedance 250/500/1k/2kΏ, Frequency Response 160-16000Hz, SPL (at 1W/1M) 88 dB, Aluminium Finish
Supply and laying 1.5 sqmm 2 core copper flexible cable Conductor for above speaker
Supply and installation of F M/AM Radio with AFC Tuner Frequency Range FM 87 to 108 MHz AM 520 to 1730 kHz, Analog Tuning Head phonejack, 110 VAC
Supply and installation of 50 to 32 Amps C curve double pole mainture circuit breaker
Supply and installation or Digital Timer switch
Supply and installation of 5 to 32 Amps Single pole c curve Mainuter Circuit Breaker
Supply and installation of fiber cubicle size of 34X 25
Interlock Work
Excavation for leveling of soil with hydrolic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side steps in accordance with requirement of line ,grades and cross sections and the transporting to the embankment location within all lift anfd lead upto 1000m
Supplying and laying interlocking tile 80 mm or nearest size thickness, then laying into lock cobbles in lin and levels a per the directions of department of officers at site inclusive of all cost & conveyance changes etc complete
Plain / reinforced cement concrete in open foundation complete as per Drawing and specifications PCC Grade m 20( without form work)
KIOSK 8'x 10'
Earthwork excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains (not exceeding 1.50M in width or 10 Sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1. Sm including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m all kinds of soil.
Solid block masonry using precast solid blocks (Factory made)of size 30x20x15 CMS ornearest available size confirming to IS 2185 parl1 of 1979 for foundation and plinth with thickness 15cm in CM 1:6 (1Cement 6Coarse sand) Etc. completed
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:2:4( 1Cement 2 Coarse Sand 4 Graded stone aggregate 20 mm nominal size
Providing and laying verified floor tiles in different sizes (Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS 156222 of Approved make in all colors and shades lied on 20mm thick cement mortar 1:4 (1Cement 4Coarse sand) including grouting the joints white cement and matching pigments etc. complete.. size of tile 600x 600
Steel work in built-up GI Tubular (Round,Square,or Rectangular hollow tube Etc.)Trusses Etc. including cutting, hoising, fixing in position and applying a priming coatof approved steel primer including welding, and bolted with special shaped washers etc.
Providing all materials and fixing 2.5mm thick weld mesh of size 2.5 cm square with allnecessary fittings.
Providing and fixing pre coated galvannealed iron profile sheet 0.50mm thickness
Proving all materials and fixing Hinges and Al drops Lumpsum
Proving and fixing on wall face unplasticized rigid PVC rain water pipes confirming to IS13592 Type A including jointing with seal ring confirming to IS 5382 leaving 1Omm gap for thermal expansion
Designing, Fabricating, Testing, installing, and fixing in position curtain wall with Aluminum composite panel cladding with open grooves for liner as well as curvilinear portions of the building
Provision for Electrification including the cost of materials and labor charges excluding
BENCHWORK & FENCING
Providing and fixing stainless steel (304) Railing maid of hollow tubes channels ,plates etc.. Including welding, grinding, buffing, polishing, and making curvature where ever required and fitting the same with necessary stainless steel nuts and bolt complete. lie,fixing the railing with necessary accessories and stainless steel dash fasteners SS bolt Etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge. (for payment purpose only Weight of stainless steel members shall be considered •excluding fixing accessories such as nut bolts, fasteners etc.).
Earthwork excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains (not exceeding 1.50M in width or 10 Sqm on plan)including dressing of sides and ramming of bottoms, lift up to 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m all kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering all work up to plinth level 1:2:4( 1Cement 2 Coarse Sand 4 Graded stone aggregate 20 mm nominal size
GI Pipe post 50mm
Finishing with Epoxy paint (Two or more coats) as per Finishing with Epoxy paint ( Two or more coats) as per manufactures specification including appropriate priming for pipe and horizontal railing
Providing and fixing GI Chain link fabric fencing of required width in mesh size 50 x 50mm including strengthening with 2mm dia wire or nuts bolt and washers are requiredcomplete as per the direction of Engineer in charge made of GI wire of dia 4mm PVCcoated to achieve outer dia not less than 5mm in required color and shade
MERKURY ELECTRICAL CORPORATION
S K ELECTRICALS
BINDU VEERAN
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .