EXECUTIVE ENGINEER (WW)-I
EXECUTIVE ENGINEER (WW)-I CHANDRAWAL WW No.01, CIVIL LINES, DELHI-54
Strengthing of LT Power supply by laying cable with allied accessary at chandrawal WW-I
2020_DJB_190877_1
NOTICE INVITING TENDER NO. - 01 (2020-21)
Open Tender
Miscellaneous Works
Item Rate
60 days
EXECUTIVE ENGINEER (WW)-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
EMD A/c No. 50448339804 at Allahabad Bank,
₹9,300
Yes
9 Jun 2020
19 May 2020
26 May 2020
19 May 2020
26 May 2020
19 May 2020
60 days
Supply of Al conductor 3.5 core 95 sqmm , PVC insulated and PVC sheathed / XLPE Insulated, PVC tape/Extruded Innersheathed for Multicore Cables, Armoured as per IS, PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 Make Polycab/Grandlay/Havells
Supply of Al conductor 3.5 core 70 sqmm , PVC insulated and PVC sheathed / XLPE Insulated, PVC tape/Extruded Innersheathed for Multicore Cables, Armoured as per IS, PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 Make Polycab/Grandlay/Havells
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length for protection of under ground cable as required. DSR 2018 code 12.38
Laying of one number Al conductor 3.5 core 95 sqmm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. DSR 2018 code 7.1.2
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)-(200m x 0.15m x 0.10m = 3 cum) DSR CIVIL 2018 vol 2 code 15.2.1
Laying of one number Al conductor 3.5 core 70 sqmm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. DSR 2018 code 7.1.3
Laying and fixing of one number Al conductor 3.5 core 70 sqmm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required with 25x3mm MS flat clamp). DSR 2018 code7.7.2
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)-(200m x 0.15m x 0.10m = 3 cum)DSR CIVIL 2018 vol 1 code 4.1.3
Fabrication/Supply/Fixing of Junction Box size (2'x2'6''x6'')-400 amp made with 16 SGW MS sheet with Powder coated Paint, insulating bush, indicating lamp, nut bolt etc and double door with both facing locking. This also include Aluminium bus bar- 4 nos , size -600mm x 50mm x 10mm , MS stand as per site requirement.
Fabrication/Supply/Fixing of Junction Box size (2'x2'6''x6'')-100 amp made with 16 SGW MS sheet with Powder coated Paint, insulating bush, indicating lamp, nut bolt etc and double door with both facing locking. This also include Aluminium bus bar- 4 nos , size -600mm x 50mm x 10mm , MS stand as per site requirement.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable 3½ X 95 sq. mm of 1.1 KV grade DSR E&M 2018 code 9.1.13
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable 3½ X 70 sq. mm of 1.1 KV grade DSR E&M 2018 code 9.1.12
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required DSR E&M 2018 code 7.10
Dismantling of overhead lines comprising of copper/ aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required. DSR E&M 2018 code 2240
GOGIA BROTHERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .