Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAdmitted-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Admitted-Finance | |
| 2 | L2₹51.1 L+₹6.3 L (14.1%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹58.1 L+₹13.3 L (29.7%)Admitted-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Admitted-Finance | |
| 4 | L4₹71.0 L+₹26.2 L (58.4%)Admitted-Finance GALI NO 2 H NO 45 2ND FLOOR NANAK VIHAR COLONY LAL KUAN GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201009 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical TECHINICALLY DISQUALIFIED |
| Sl No | Description | Qty | Unit | R J ENTERPRISES L3 | A.K. ENGINEERING COMPANY L4 | Chakshu Enterprise L1 | ELECTRO ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Cope Point C1
Labour Charges for Removal of Existing XLPE, Al Conductor Power Supply Cable from LTACB Panel to Power Junction Box nos. 1, 2 & 3, Size: 3C x 400 Sq mm, two runs of Cope Point C1 of CG dock alongwith accessories all as specified in RFP. | 546 | mtrs | 200 ₹1,09,200 | 343 ₹1,87,278 | 100 ₹54,600 | 85 ₹46,410 Lowest |
| 2.00 | Labour Charges for Removal of Existing Power Junction Box nos. 1, 2 & 3 of Cope Point C1 of CG dock alongwith accessories all as specified in RFP. | 3 | nos | 3,500 ₹10,500 Lowest | 15,333 ₹45,999 | 10,000 ₹30,000 | 7,500 ₹22,500 |
| 3.00 | Labour Charges for Removal of Existing Flexible Copper Conductor Power Supply Cable from Power Junction Box nos. 1, 2 & 3 to Cope Points (1, 2 & 3), Size: 1C x 240 Sq mm, two runs of Cope Point C1 of CG dock alongwith accessories all as specified in RFP. | 360 | mtrs | 200 ₹72,000 | 160 ₹57,600 | 100 ₹36,000 | 75 ₹27,000 Lowest |
| 4.00 | Cost of XLPE Insulated Screened PVC Bedded Galvanized Steel Strip Armoued Heavy Duty LT Electrical Power Cable With Copper Conductor 1.1 kV Grade of Size 3C x 300 Sq mm, two runs of Cope Point C1 of CG dock all as specified in RFP. | 546 | mtrs | 7,300 ₹39,85,800 | 8,846 ₹48,29,916 | 6,250 ₹34,12,500 Lowest | 6,962 ₹38,01,252 |
| 5.00 | Labour Charges for above works i.e. Laying & Commissioning all as specified in RFP. | 546 | mtrs | 300 ₹1,63,800 | 527 ₹2,87,742 | 150 ₹81,900 Lowest | 205 ₹1,11,930 |
| 6.00 | Cost of Supply & Design of Power Junction Boxes with MCCB’s 800A, 3P, 50 kA of with GI Stand made of 50 x 50 x 5 mm equal angle with copper bus bas bars of suitable rating of Cope Point C1 of CG dock all as specified in RFP. | 3 | nos | 1,55,000 ₹4,65,000 | 2,30,000 ₹6,90,000 | 75,000 ₹2,25,000 Lowest | 1,05,600 ₹3,16,800 |
| 7.00 | Labour Charges for above works i.e. Fitment & Commissioning all as specified in RFP. | 3 | nos | 12,000 ₹36,000 | 19,167 ₹57,501 | 10,000 ₹30,000 Lowest | 30,000 ₹90,000 |
| 8.00 | Cost of XLPE insulated screened PVC bedded flexible heavy duty LT electrical power cable with Copper conductor 1.1 kV grade size: 1C x 240 sq mm, two runs all as specified in RFP. | 360 | mtrs | 2,400 ₹8,64,000 | 2,300 ₹8,28,000 | 1,600 ₹5,76,000 Lowest | 1,830 ₹6,58,800 |
| 9.00 | Labour Charges for above works i.e. Laying & Commissioning all as specified in RFP. | 360 | mtrs | 300 ₹1,08,000 | 320 ₹1,15,200 | 100 ₹36,000 Lowest | 110 ₹39,600 |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
13 Aug 2020, 2:00 pmClosed
MPM
MPM AT NAVAL DOCKYARD, MUMBAI
REPLACEMENT OF 3C X 300 SQ MM, 1KV, XLPE COPPER POWER SUPPLY CABLE FROM SUB STATION TO COPE POINT FOR CNO.66 YAS DEPT. AT NAVAL DOCKYARD, MUMBAI
2020_NAVY_362134_1
DYT/CC/0154/02/20-21/111(i)
Open Tender
Miscellaneous Services
Multi-stage
240 days
C.NO.66, MYAS DEPT AT NAVAL DOCKYARD MUMBAI
AS PER RFP
4 documents required · 4 mandatory
₹0
₹1.9 L
Yes
C.NO. 66 MYAS DEPT AT ND (MBI)
18 Nov 2020
18 Jul 2020
14 Aug 2020
18 Jul 2020
13 Aug 2020
18 Jul 2020
18 Jul 2020 - 13 Aug 2020
24 Jul 2020
Amount
Cope Point C1 Labour Charges for Removal of Existing XLPE, Al Conductor Power Supply Cable from LTACB Panel to Power Junction Box nos. 1, 2 & 3, Size: 3C x 400 Sq mm, two runs of Cope Point C1 of CG dock alongwith accessories all as specified in RFP.
Labour Charges for Removal of Existing Power Junction Box nos. 1, 2 & 3 of Cope Point C1 of CG dock alongwith accessories all as specified in RFP.
Labour Charges for Removal of Existing Flexible Copper Conductor Power Supply Cable from Power Junction Box nos. 1, 2 & 3 to Cope Points (1, 2 & 3), Size: 1C x 240 Sq mm, two runs of Cope Point C1 of CG dock alongwith accessories all as specified in RFP.
Cost of XLPE Insulated Screened PVC Bedded Galvanized Steel Strip Armoued Heavy Duty LT Electrical Power Cable With Copper Conductor 1.1 kV Grade of Size 3C x 300 Sq mm, two runs of Cope Point C1 of CG dock all as specified in RFP.
Labour Charges for above works i.e. Laying & Commissioning all as specified in RFP.
Cost of Supply & Design of Power Junction Boxes with MCCB’s 800A, 3P, 50 kA of with GI Stand made of 50 x 50 x 5 mm equal angle with copper bus bas bars of suitable rating of Cope Point C1 of CG dock all as specified in RFP.
Labour Charges for above works i.e. Fitment & Commissioning all as specified in RFP.
Cost of XLPE insulated screened PVC bedded flexible heavy duty LT electrical power cable with Copper conductor 1.1 kV grade size: 1C x 240 sq mm, two runs all as specified in RFP.
Labour Charges for above works i.e. Laying & Commissioning all as specified in RFP.
ELECTRO ASSOCIATES
R J ENTERPRISES
A.K. ENGINEERING COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .