Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC N A | PALWAL | HARYANA | 121004 | ₹3.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹3.8 Cr+₹22.1 L (6.25%)Rejected-Finance 32 9 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹3.8 Cr+₹22.1 L (6.25%) | L2 | Rejected-Finance Highest Rate Quoted by bidder |
| 3 | L3₹3.8 Cr+₹29.2 L (8.26%)Rejected-Finance CORPORATE OFFICE E BLOCK E44 GROUND FLOOR SECTOR 36 G B NAGAR 201310 | NAGAR | G B NAGAR | UTTAR PRADESH | 201310 | ₹3.8 Cr+₹29.2 L (8.26%) | L3 | Rejected-Finance Highest Rate Quoted by bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non Technically Qualified |
Tender Value
₹3.8 Cr
EMD Value
₹7.7 L
Closing Date
13 Dec 2022, 5:00 pmClosed
General Manager(Garhwal)
Office of Chief General Manager, Construction Wing, Uttarakhand Peyjal Nigam, 403/1 Indira Nagar, Dehradun
ADDITIONAL WORK OF SHOOTING RANGE AT M.P.S.C., RAIPUR, DEHRADUN
2022_MDPEY_52051_1
4857/Nivida(Garh)Khel D.Dun/163 Dt. 24-11-2022
Open Tender
Civil Works
Item Rate
365 days
RAIPUR
Please refer tender document
3 documents required · 3 mandatory
₹5,900
PM, Temp.Const.Unit(Khel), UKPJN, Dehradun
₹7.7 L
Dehradun
17 Feb 2023
25 Nov 2022
15 Dec 2022
26 Nov 2022
13 Dec 2022
30 Nov 2022
29 Nov 2022
Amount
NSI Item- Provinding and fixing 50mm thick Pine wood planks on ceiling and Bullet arrestor incluiding all cecessary screws batens T& P complete.
NSI Item- Supply and installation of BWF approved Elite PVC VINYL 4.5 mm flooring of make Grabo, Topflor, Benow sports that should be compliance with the area elastic and shock absorption >25%, ball bounce> 98% surface complex 100% PVC.
DSR Item- 12.5 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
DSR Item- 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
DSR Item- 9.105.4 66mm overall thickness partition using 8mm thick double skin multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS : 14862 with suitable fibre cement screws
DSR Item- 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
DSR Item- 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
DSR Item- 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
DSR Item- 5.37.1 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level
DSR Item- 5.9.2 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
DSR Item- 5.9.6 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
DSR Item- 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
DSR Item- 5.9.3 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
DSR Item- 5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
NSI Item- 8 PASSENGER LIFT Supply, Installation Testing & Commissioning of Regenerative 8 Passanger / 680 KG Lift having speed of 1.5 MPS 2 stops (GR & 1st Floor ) and 2 openings and total travel of 8.00 meters approx. with VVVF drive, suitable for with Machine room full collective Simplex control on 415 V, 50 cycles, 3 phase power, complete in accordance with specifications, Lift well size 2250MM(W) x 2000MM(D), car in side 1300 MM(W) x 1350 MM(D), 800 mm(W) X 2100 mm (H) central oepning. as per OEM, drawings as required with Car, Car Door & Hoistway Door in stainless steel hairline finish, CCTV camera inclusive of built in ARD and as per specification.
DSR VRV/VRF 2019 Supplying, installing, testing and commissioning of Both Cooling & Heating Modular Type Outdoor Condensing Units equipped with highly efficient Inverter scroll compressors to work on 415 V, 50 Hz AC suply with digital/ inverter technology, special acryl precoated heat exchanger, low noise condenser fan with motor, auto check function for errors in display panel, auto address setting, as per specifications. The COP at AHRI conditions shall not be less than 3.8 .The units shall be complete with necessary mounting frames. Outdoor Unit (ODU shall be provided with cowl duct of minimum 10 to 15 mm ESP)
14 HP (1x14 HP)
20 HP (1x20 HP)
40 HP(2x20HP)
DSR VRV/VRF 2019 Supplying, installing, testing and commissioning of Ceiling Suspended Cassette Type Indoor Units each complete with coil, filter, etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor and 220 volt, 1 phase, 50 Hz, AC supply all as per specifications. The rate will also include entire drain pipes and nothing extra shall be payable.
DSR VRV/VRF Item- 2.5 2.1 TR (650 CFM)
DSR VRV/VRF Item- 2.7 2.7 TR (775 CFM)
DSR VRV/VRF Item- 2.1 4.1 TR (1250 CFM)
DSR VRV/VRF 2019 Supplying, installing, testing and commissioning of Ceiling Suspended Duct Type Indoor Units each complete with coil, filter, etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor and 220 volt, 1 phase, 50 Hz, AC supply all as per specifications. The rate will also include entire drain pipes and nothing extra shall be payable. Medium Static (Minimum 50 pascal). High Static (Minimum 110 pascal)
DSR VRV/VRF Item- 4.16 4.0 TR (1450 CFM)
DSR VRV/VRF Item- 4.16 4.5 TR (1650 CFM)
DSR VRV/VRF Item- 4.17 5.5 TR (2050 CFM)
NSI Item- Supply, installation, testing and commissioning of Imported fittings Y-joints, distributer and headers for all Indoor units as per layout drawings.
NSI Item- Supply, installation, testing and commissioning of Corded/Cordless Remote controllers for operation of indoor units
NSI Item- Supply, installation, testing and commissioning of Central Remote Controller for complete system including all VRV/VRF indoor and outdoor units.
NSI Item- Supply, installation, testing and commissioning of Scheduled Timer.
NSI Item- Supply, installation, testing and commissioning of factory built Air handling units Double skin type with 46 mm thick panels consisting of Polished SS Sheet casing of thickness 0.6 mm outside layer and 0.6 mm inside layer and polyurethene foam(PUF) insulation having density of 42 kg/m3,complete with direct driven backward curved / Plug Fan with for static pressure as detailed below, DX type 6 Row cooling coil with aluminum finned copper tubes, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in the supply side of AHU, Hepa filter section with filters of non woven synthetic media of 3 micron particle size , mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with TEFC motor suitable for 415 +10% volts,50 Hz, 3 phase AC supply, drain connections with necessary vibration isolation arrangement to avoid any vibration etc. complete as per specifications and drawings. The AHU panels shall be thermo acoustic insulated with 46 mm thick & shall have thermal break. The motor & blower assembly shall be mounted on Aluminum extruded section only. The complete AHU shall conform to standard specification. The face velocity across coil shall be limited to 152 MPM maxim. The capacity of Air-handlers shall be as follows. The static pressure given below is for guidance only actual to be calculated by vendor. 3000 CFM(15TR),6 Row,65 mm St. Pr.
NSI Item- Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electronic Expansion Valve (EEV) and temperature set arrangement. It Shall have cut off arrangement after a particular set value of Supply air Temperature. AHU Kits & Controllers
NSI Item- Supply, installation, testing and commissioning of digital display type thermostat for various air handling Units. Temperature Sensor of AHU shall be in BMS Part. The thermostat shall have provision of setting of space temperature and shall display the space RH. Cooling / heating Digital display type common thermostat & humidistat to be installed in OT & shall have temperature & RH setting control from OT or if when required. Cooling / heating thermostat for AHU
DSR VRV/VRF 2019 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
DSR VRV/VRF-5.1 6.4 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.2 9.5 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.3 12.7 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.4 15.9 mm Outer dia (OD) Soft Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.5 19.1 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.6 22.2 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.7 25.4 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.8 28.6 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.2mm (insulation: 19 mm)
DSR VRV/VRF-5.9 31.8 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.62mm (insulation: 19 mm)
DSR VRV/VRF-5.10 34.9 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.62mm (insulation: 19 mm)
DSR VRV/VRF-5.11 38.1 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.62mm (insulation: 19 mm)
DSR VRV/VRF-5.12 41.3 mm Outer dia (OD) Hard Drawn with Tube Thickness-1.62mm (insulation: 19 mm)
NSI Item- Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell expanded polythene.
NSI Item- Supplying, installing, testing and commissioning of Air Cooled Invertor Split type wall mounted 5 Star Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Nothing extra shall be paid on any account i.e. refrigerant pipes, drain pipes etc.
Capacity : 1.5 TR
Sequential Timer
NSI Item- Supplying, installing, testing and commissioning of control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units. 2C x 1.5 Sq mm (Unarmoured)
DSR Item- 16.12.1 Item- Supply. Installation, testing and commissioning of factory fabricated G.I. Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
DSR Item- 16.12.1.1 0.63 MM (24 Gauge )
DSR Item- 16.12.1.2 0.80 MM (22 Gauge )
DSR Item- 16.12.1.3 1.00 MM (20 Gauge )
DSR Item- 16.12.1.4 1.25 MM (18 Gauge) Plenum
DSR Item- 16.23 Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications.
DSR Item- 16.23.1 19 mm
DSR Item- 16.23.2 25 mm
NSI Item- Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
DSR Item- 16.13 Supply. Installation, testing and commissioning of G.I construction Duct/ Volume control Dampers for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.
DSR Item- 16.16 Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification.
DSR Item- 16.15 Supply. Installation, testing and commissioning of powder coated extruded aluminum section grills with dampers for supply air terminal for air-conditioning as per specification.
DSR Item- 16.17 Supply. Installation, testing and commissioning of powder coated extruded aluminum square diffusers with antismudge ring and removable core.Supply air with dampers
DSR Item- 16.18 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core
NSI Item- Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm
NSI Item- Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.
3-Slot Diffuser
2-Slot Diffuser
NSI Item- Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.
NSI Item- Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminum construction with bird screen, minimum 80 mm deep.
DSR Item- 16.20.1 Fire Damper with Spring and Fusible Link Supplying, installation, testing and commissioning of Fusible Link type fire and smoke dampers of 18 gauge GI sheet construction suitable for 120 minute fire rating.
DSR Item- 16.20 Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
DSR Item- 16.20.2 Actuator
NSI Item- Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 25mm
NSI Item- Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure of suitable for VRV Outdoor Unit. 63A 4P MCCB(16 KA)
NSI Item- Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender.A) Power cabling (XLPE insulated Aluminum / Copper conductor as given below armoured / unarmoured cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc. as per specification. Note:- Power cable with earthing shall be made available near indoor / outdoor units. Only termination into HVAC equipment's (Indoor & Outdoor) shall be done by HVAC Contractor.
4C x 16 Sq. mm Copper Conductor (Armoured) For VRF Unit
4C x 10 Sq. mm Copper Conductor (Armoured) For AHU/Vent
4C x 6 Sq. mm Copper Conductor (Armoured) For AHU/Vent
4C x 4 Sq. mm Copper Conductor (Armoured) For AHU/Vent
DSR Item- 4.1 Supply, fabrication & installation of perforated hot dipped galvanised (Galvanisation as per latest IS 4759/6745) double bended cable trays from 1.6/2.0 mm thick GI sheets continuously connected including horizontal and vertical bends, reducers, tees, and other accessories and duly suspended from the ceiling with 10 mm dia vertical GI rods supported by 40mm x 40 mm x 5 mm GI angle etc. (or installed on wall supported on suitable brackets as required) complete as per specifications, as required and as below.
DSR Item- 4.1.7 600 mm wide x 50 mm deep with 2.0 mm Thickness
DSR Item- 4.1.6 450 mm wide x 50 mm deep with 2.0 mm Thickness
DSR Item- 4.1.4 300 mm wide x 50 mm deep with 1.6 mm Thickness
DSR Item- 4.1.2 150 mm wide x 50mm deep with 1.6 mm Thickness
DSR Item- 1.14 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
DSR Item- 1.14.6 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
DSR Item- 1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
DSR Item- 1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
DSR Item- 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
DSR Item- 2.3.4 16 way, Double Door
DSR Item- 2.3.3 12 way, Double Door
DSR Item- 2.4.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way (4+18), Double Door
DSR Item- 2.5.3 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
DSR Item- 2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR Item- 2.12.1 40 Amp
DSR Item- 1.12.2 63 Amp
DSR Item- 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR Item- 2.14.2 40 Amp
DSR Item- 2.14.3 63 Amp
DSR Item- 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR Item- 2.15.2 40 Amp
DSR Item- 2.15.3 63 Amp
NSI Item- Supply, Installation, Testing & Commissioning of 8 watt 1000 lumen LED Recess mounted down Light. (Philips Make-DN295B LED10S-6500 PSU WH)
NSI Item- Sopply, Installation, Testing & Commissioning of 12 watt 1200 lumen Surface Mounted down Light. (Philips Make-SM250C LED12S- 6500 PSU WH)
NSI Item- Supply, Installation, Testing & Commissioning of 22 watt 2500 lumen Surface Mounted Light. (Philips Make-BN021C LED22S PSU CW GR)
NSI Item- Installation, Testing & Commissioning of 18 watt 2000 lumen LED Recessed mounted Light. (Philips Make-DN296B LED20S-6500 PSU WH)
NSI Item- Supply, Installation, Testing & Commissioning of 17 Watt LED 2000 lumen wall/ Ceiling Mounted LED Tube Light. (Philips Make-BN100C LED20S-6500 PSU L120 GR S4)
NSI Item- Supply, Installation, Testing & Commissioning of 31 Watt 3600 lumen, LED (600x600mm) Recessed Light. (Philips Make-RC380B LED36S-6500 G6 L60W60 PSU OD)
NSI Item- Supply, Installation, Testing & Commissioning of 6.5Watt 700 lumen Bulk Head Light(Philips Make-WT140W LED7S CW PSU S1 PC)
NSI Item- Supply, Installation, Testing & Commissioning of 35Watt 4000 lumen LED light. (Philips Make-SP095V LED40S 865 W7L120 PSU WH)
NSI Item- Supply, Installation, Testing & Commissioning of 155 W 18300lumen LED Light. (Philips Make-BVP483 LED185 CW NB PSU GR)
NSI Item- Supply, Installation, Testing & Commissioning of 35 W 4200lumen LED Light. (Philips Make-RC380B LED42S-6500 G6 L60W60 PSU OD)
NSI Item- Supply, Installation, Testing & Commissioning of 80 W 9000 lumen LED Light. (Philips Make-BY286V LED90S CW SK PSU FG WH)
NSI Item- Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. 6 way
NSI Item- Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 40 mm deep. (Three Partition)
200 mm wide x 40 mm deep. (Three Partition)
100 mm wide x 40 mm deep. (Single Partition)
200 mm wide x 40 mm deep. (Single Partition)
NSI Item- Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.
150 mm wide x 50 mm deep. (Three Partition)
250mm wide x 50 mm deep (Three Partition)
150mm wide x 50 mm deep (Single Partition)
250mm wide x 50 mm deep (Single Partition)
DSR Item- 4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
DSR Item- 4.6.1 100 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.6.2 150 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.6.4 300 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.6.6 450 mm wide x 50 mm depth x 2.0 mm thickness.
DSR Item- 4.7 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
DSR Item- 4.7.1 100 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.7.2 150 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.7.4 300 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.7.6 450 mm wide x 50 mm depth x 2.0 mm thickness.
DSR Item- 4.8 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
DSR Item- 4.8.1 100 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.8.2 150 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.8.4 300 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.8.6 450 mm wide x 50 mm depth x 2.0 mm thickness.
DSR Item- 4.9 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
DSR Item- 4.9.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR Item- 4.9.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR Item- 4.9.4 300 mm width X 50 mm depth X 1.6 mm thickness
DSR Item- 4.9.6 450 mm width X 50 mm depth X 2.0 mm thickness
DSR Item- 4.10 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
DSR Item- 4.10.1 100 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.10.2 150 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.10.4 300 mm wide x 50 mm depth x 1.6 mm thickness.
DSR Item- 4.10.6 450 mm wide x 50 mm depth x 2.0 mm thickness.
DSR Item- 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
DSR Item- 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
NSI Item- Supply, Installation, Testing & Commissioing of 60 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transformer as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range.UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be external type with rack and suitable for 30 minute backup on 100% load. Suitable size of copper cable between UPS and battery bank shall be provided. UPS shall be compatible for 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS. UPS described as above
NSI Item- Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Storing, Installation, Testing and Commissioning of Radiator Cooled DG sets with AMF panel capacity of (rating in 250 kVA) compact packaged silent type, with Outdoor type Acoustic Enclosure to reduce the noise level as per requirements of central pollution control board, (72 db from 3 mtrs.) 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with Electronic Governer Suitable for Auto Load Sharing and Auto Synchronizing System complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), hospital silencer, common bed plate, anti vibration isolation pads, extended cable termination box, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 24 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. NOC from concerned goverment authority for installation and operation of D.G. set shall be taken by contractor. D.G. Set shall be as per CPCB-II with suitable foundacation height of 2' including staire all side.(I/C 335 BHP, 6 cylender,1500rpm, turbo charge after cooled electronic governor, 24 Volt electric start with inbuilt fuel tank coupeld with 250KVA, 415 V, 3 phase, 1500rpm alternator along with AMF panel cosisting of MCCB, battery charger and other standard accessories I/C Sitaibale foundetion for DG set up to 06 mtr above ground labale with stair. 250 KVA D.G. Set
NSI Item- Supply, installation, testing and commissioning of following sizes MS exhaust piping heavy duty conforming to IS : 1239 & 3589 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc. and fixing/ supporting arrangement above 3 meter height of terrace of building icluding structural supporting of exhaust pipe etc. as required.150 mm dia MS pipe. (4.8 mm thick)
NSI Item- Providing & Fixing of Insulation and aluminium cladding for exhaust piping using 75 mm thick rockool of density 150 Kg/ M3 & 24 SWG Aluminium Sheet.
NSI Item- Fabrication, supply & erection of MS structure for supporting of DG emission, exhaust piping with RCC foundation and in cable trench for cable support etc. complete in all respect etc. complete as required.
NSI Item- Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.
1C x 50 sq.mm PVC Insulated cu wire including termination etc.
1C x 35 sq.mm PVC Insulated cu wire including termination etc.
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares. Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (125 KVA). Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same. The Contactor shall be electrically interlocked with the bus coupler DG SET and Transformer incomer.BUSCOUPLER 1 Nos. 250Amp FP MCCB with 250A FP Power Contractor.1 Sets of indicating lamps for ON & OFF of bus coupler.BUSBARS- 1 sections of 800 Amp & 2 sections of 300 AmpTPN busbars of aluminium alloy as per SLD. OUTGOING- EACH OUTGOING FEEDER SHALL HAVE DOUL SOURCE ENERGY METER, 02 Nos 315A TP MCCB (25 KA).03 Nos 250A TP MCCB (25 KA).02 Nos 100A TP MCCB (25 KA).01 Nos 63A TP MCCB (25 KA).Essential Main L.T. Panel Describe as above.
VKJ Projects Pvt. Ltd.
LISHA ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .