Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | ₹23.0 L Quoted ₹23.5 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹25.7 L+₹2.3 L (9.60%)Rejected-Finance | ₹25.7 L+₹2.3 L (9.60%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹25.8 L+₹2.3 L (9.73%)Rejected-Finance | ₹25.8 L+₹2.3 L (9.73%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹26.0 L+₹2.6 L (10.9%)Rejected-Finance 0 GRAMTHANG MINJEE KARGIL KARGIL LADAKH 194105 | KARGIL | LADAKH | 194105 | ₹26.0 L+₹2.6 L (10.9%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹26.1 L+₹2.6 L (11.2%)Rejected-Finance | ₹26.1 L+₹2.6 L (11.2%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
11 Aug 2021, 6:00 pmClosed
CWE Khumbathang
CWE Khumbathang
REPAIR TO RETAINING WALL, PLATFORM, FOOTPATH AND REPAIR/ CLEANING OF SEWAGE LINE/ SOAKAGE WELL AND SEPTIC TANKS IN VARIOUS UNITS AT BUDHKHARBU AND HENISKOT UNDER GE KARGIL
2021_MES_442783_3
CWE/K-08/2021-21
Open Tender
Miscellaneous Works
Item Rate
335 days
GE Kargil
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
GE Kargil
₹46,000
Yes
6 Sept 2021
26 Jul 2021
13 Aug 2021
26 Jul 2021
11 Aug 2021
3 Aug 2021
Amount
Dewatering and cleaning of septic tank, incl removing water sludge with water, waste material from tanks/pits and depositing off the material to a distance n.exc. 200 mtrs and burrying in pits and filling pits with earth complete all as specified and directed by Engr-in-Charge. (rate include labour for making pits and one labour daily report to AGE B/R-II office for any complaints).
Dewatering and cleaning of soakage well/ Soakage pits, and depositing off the material to a distance n.exc. 200 mtrs and burying in pits and filling pits with earth complete all as specified and directed by Engr-in-Charge (rate include labour for making pitsone labour daily report to AGE B/R-II office for any complaints).
M&L dewatering & cleaning of sokage well & septic tank using honey sucker/Sludge sucker with machine carring capacity 3000 ltr and dispose off material complete all as specified and directed by Engr-in-Charge.
M&L cleaning of sewage lines and blockage by roding using bamboo split or by mechanical means from man holes to MH, Nanhi traps to gully traps, gully trap to man holes together with vertical stack pipes (where ordered) , cleaning eye to gully trap and taking out all debris, sludges or any solid / foreign materials from sewage line and removing the debries from site and flushing with water man hole to man hole & testing after cleaning complete for pipe line of dia 100mm/150mm/200mm complete all as specified and directed by Engr-in-Charge.
M&L for cleaning of blockage/filled any type and cleaning of freezed water and accumulated sludge by heating method with blow lamps or nay other method and roding the cast iron pipes 100mm bore/SGSW pipe 150mm bore upto soakage well without damaging the WC and pipe all as directed by Engr-in-Charge.
Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing serviceable like to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
Demolition of RCC of any description and in any position including disposal of old materials to a distance exceeding 500 M but not exceeding 1.0 KM, complete all as specified and directed by Engr-in-Charge.
Demolition of brick or stone/block masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up PVC drain and like pipes any size, complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing & connections, including cleaning for re-fixing or removal to store of 15mm bore, complete all as specified and directed by Engr-in-Charge.
All as per item No 11.00 above but 20 mm bore.
M&L for Non-skid coloured ceramic tiles, 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles, comp laid over including 15 mm thick screed bead in CM 1:4, complete all as specified and directed by Engr-in-Charge.
M & L for Glazed ceramic coloured tiles of size 300x200x7 mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 10 mm thick rendering in CM (1:4), complete all as specified and directed by Engr-in-Charge.
M&L for machine pressed compacted interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement without no pigment, complete all as specified and directed by Engr-in-Charge.
M&L 30mm thick sand cushioning under floors including watering and consolidation complete all as specified and directed by Engr-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge.
Excavation over area not exceeding 1.5 m depth and getting out in hard/ dense soil, complete all as specified and directed by Engr-in-Charge.
All as per item No 18.00 above but exceeding 1.5 m and not exceeding 3.00 m depth.
M & L for cement concrete type D-2 1:4:8 (using 40mm aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for chequered cemnt concrete tiles 200x200x25mm thick set, jointed and pointed in neat slurry in floors with grey cement & no pigment including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
Rendering 15 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 Cm thick complete all as specified and directed by Engr-in-Charge.
Removing surplus excavated soil to a distance not exceeding 100 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge.
M&L RCC M-25 Design Mix as in slabs supported on walls, beams and columns in floors, roofs, complete all as specified and directed by Engr-in-Charge.
Use & waste form work to soffits of suspended slabs, such as roof slabs, landings and similar work not exceeding 200 mm thick with rough finished flat surfaces of concrete, complete all as specified and directed by Engr-in-Charge.
Supply and fixing mild steel TMT bars 6 to 8 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fixing mild steel TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
Supply only water proofing compound ISI marked complete all as specified and directed by Engr-in-Charge.
Precast reinforced cement concrete, type B-1,1:2:4 (using 20mm graded crushed stone aggreagate)as in manhole cover set in cement mortor 1:4 , complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 75mm bore pipe complete all as specified and directed by Engr-in-Charge.
All as per item No 33.00 above but 110 mm bore pipe.
M & L for 100mm thick concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 100 mm bore, complete all as specified and directed by Engr-in-Charge.
M & L for 150mm thick concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 150 mm bore, complete all as specified and directed by Engr-in-Charge.e
S&F in repair PVC (SWR) vent cowl 110mm in bore complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) bends any radius of 110mm bore complete all as specified and directed by Engr-in-Charge.
Dismantling PVC water tanks of capacity exc 250 but n exc 500 ltr and removing to store complete all as specified and directed by Engr-in-Charge.
All as per item No 39.00 above but capacity Exc 500 but not exc 1000 ltr.
S & F 500 Ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted, Double layer and fixed in position including 2 Nos 25 mm dia tank nipples and 1 No 32 mm dia drain plug with rings all as specified in SSR Part I complete all as specified and directed by Engr-in-Charge.
All as per item No 41.00 above but capacity 1000 ltr.
S & F in repairs stainless steel squatting pan of pattern “long pan”, size 580 x 440 mm standard ivory with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in Charge.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including seat cover complete all as specified and directed by Engr-in Charge
S& F in repair one piece EWC with seat cover and fittings 100 WD, 710 x 370 x 745 mm, mordern curvy design with flushing efficiency 3.9/2.1 LPF, the shade of EWC approved by EIC, complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC low level valveless, flushing cistern 10 Ltr capacity with inlet , ball valve, float valve and handle & including brackets for fixing to walls and PVC flush pipe of LDPE pipe of pressure rating 6 kg (f)/ sq.cm complete all as specified and directed by Engr-in-Charge.
S & F in repairs for 15 mm pillar taps,cast copper alloy fancy type with chromium plated screwed down,screwed for iron pipe complete all as specified and directed by Engr-in-Charge.
S & F in repairs urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified and directed by Engr-in-Charge.
S & F in repairs stop valves suitable for 15 mm bore iron pipe, cast copper alloy, chromium plated, screwed down, high pressure, fancy type, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S&F in repairs Bib taps 15 mm bore,fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in repairs Vitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe & waste pipe) complete all as specified and directed by Engr-in Charge.
S&F in repairs Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed by Engr-in Charge.
S&F 16mm dia 3-layer PP-R ( Polylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed by Engr-in-Charge.
All as per item No 53.00 above but 20mm dia.
M/S M A ENTERPRISE
M/S Hussani Enterprises Kargil
M/S MOHD ALI
M/S SAJJAD HUSSAIN
M/S MOHD KHAN
M/S B K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .