Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest Bidder | |
| 2 | L2₹15.0 L+₹59,853 (4.15%)Rejected-Finance | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹15.9 L+₹1.5 L (10.2%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹16.0 L+₹1.5 L (10.7%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹16.2 L+₹1.8 L (12.3%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹16.9 L
Closing Date
23 Sept 2021, 3:00 pmClosed
SM(E-E), AAI,Surat Airport, Surat
Office of SM(E-E), AAI, Surat Airport, Surat
Replacement of DG Set of DVOR at Surat Airport
2021_AAI_85454_1
AAI/SRT/SM(E-E)/e-NIT-08/21-22
Open Tender
Electrical Works
Item Rate
120 days
AAI, Surat Airport
As per NIT
18 documents required · 18 mandatory
₹1,180
Exempted
10 Nov 2021
13 Sept 2021
24 Sept 2021
13 Sept 2021
23 Sept 2021
13 Sept 2021
13 Sept 2021 - 20 Sept 2021
Amount
DIESEL GENERATOR SETS
SITC of minimum 40 KVA prime power D.G. Set with acoustic enclosure conforming to latest environment regulations for emmission and noise levels complete with Diesel Engine of suitable BHP (considering de-rating factor if any) at 1500 RPM, water cooled, (Radiator type), four stroke, electric start, turbo-charged & inter/after cooled conforming to BS: 5514 with all standard accessories, coupled with alternator of 40KVA rating prime power rated, brushless, self excited, self regulated and suitable for continuous operation, generation 415 V +/- 5% Volts at 0.8 PF (lag), 50Hz, 3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. along with DG set command control panel complete as required. Both Engine and Alternator shall be mounted on common channel iron base frame, with complete fuel pipe line, antivibration mountings, residential type silencer , batteries & battery charger, minimum 95 ltr inbuild HSD tank (day tank) with level indicator, first fill of lubricating oil, filling of sufficient diesel for testing & commissioning, and all mandatory accessories, complete with neccessary civil work of making cement concrete foundation for placing the DG set, grouting, chipping, finishing with cement etc as recommended by OEM and as per site condition etc as required. The work shall be as per C.E.A/Electrical inspectorate standards.
Insulated Exhaust Piping with aluminium cladding : Supply, installation, testing and commissioning of insulated MS exhaust pipe of 100mm dia with aluminium cladding of suitable length conforming to class - C as per relevant IS , i/c insulation of complete exhaust piping with mineral wool/rock wool of appropriate thickness and density, suitable for higher temperature with 24 SWG aluminium cladding (around the exhaust pipe) and fixing / supporting arrangement for piping, insulation & aliminium cladding etc. with all other required accessories such as bends, flanges, stainless steel flexible bellows . complete as required.
Supply of following sizes of XLPE insulated PVC sheathed, aluminium conductor, armoured, power cable of 1.1 KV grade conforming to IS 7098 (Part I), 1988 amended upto date.
3.5 x 70 Sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm
Outdoor LT Feeder pillar Panel (PTTA)
Outdoor LT Feeder pillar Panel (PTTA)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20 mm dia medium class GI watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and and 20 mm dia medium class GI watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia medium class G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia medium class G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5 X 240 sqmm
3.5 X 70 sqmm
4 X 10 sqmm
Dismantling/ Opening of already terminated PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV with brass compression gland and aluminium lugs by cutting the cable and pluging the hole with sealant after drawing the cable for following size as required.
3.5 X 240 sqmm
4 X 35 sqmm
4 X 16 sqmm
4 X 10 sqmm
Dismantling of existing installed Feeder panel of approx size of 1.78 x 1.34 x 0.55 mtr. i/c taking of dismantaled Feeder panel to the within Airport premises as per direction of Engineer-in-Charge.
Dismantling of existing installed 32.5 KVA DG set i/c taking of dismantaled DG set to the within Airport premises as per direction of Engineer-in-Charge.
SHEKHAWATI BUILDCON PRIVATE LIMITRD
Awasthi Electric Works
Mona Generator Services Pvt. Ltd.
Manish Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .