| 4 | Rejected-Technical VILL BAREGAON PO CHAK CHAKA BAZAR DIST BARPE | BARPETA | ASSAM | 781301 | Rejected-Technical Not requisite category as per NIT |
Tender Value
₹32.4 L
EMD Value
₹64,800
Closing Date
22 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) TEZPUR
GE (N) TEZPUR
SPL REPAIR ELECTRIC MES INSTALLATIONS AT THAKURBARI AND CERTAIN LBW/REV WORKS UNDER GE (NORTH) TEZPUR
2020_MES_338818_1
GE(N)/TEZ/2020-21/8405
Open Tender
Civil Works
Item Rate
240 days
TEZPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (N) TEZPUR
₹64,800
Yes
16 Oct 2020
21 Jul 2020
24 Aug 2020
21 Jul 2020
22 Aug 2020
10 Aug 2020
21 Jul 2020 - 4 Aug 2020
60 days
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Surface dressing n.exc 15cm deep soft/loose soil
Excavation in trenches, n-exc 1.5 m wide and n-exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, Manhole, Pier Holes, etc and getting out soft/loose soil.
M & L Hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface with broken bricks
M & L plain cement concrete type D2 1:4:8 in foundations, filing & mass concrete.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (20mm graded aggregate) as in sub base under floor
M&L for 50 mm thick cement concrete type D-2, 1:4:8 (20mm graded aggregate) as in sub base under floor
M&L for 75 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base under floor
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (20 mm graded aggregate) to receive the top layer of tiles
M&L for 75mm thick cement concrete type C-2,1:3:6(40mm graded aggregate) as in plinth protection making finished even and smooth without using extra cement.
M & L brick work with subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6
M&L for brickwork with sub class’B’ bricks, straight or curved on plan exc 6m mean radius in half brick work built in CM 1:4.
M&L for 20mm thick in cement mortar 1:2 damp proof course to horizontal or vertical surfaces with WPC including necessary formwork, as directed
M&L 15mm thick plastering on fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement in CM 1:4 complete all as specified and as directed.
M&L for rendering 10 mm thick plastering on fair faces of brickwork surfaces in cement mortar (1:6) making smooth and even surfaces without using extra cement complete all as specified and as directed.
M&L for providing precast cement concrete type B1 1:2:4 using 20mm graded aggregate in door cills, lintels bressumers, copings and setting in cement mortar 1:4 complete with joints to match
Ditto as above , but in landings, cover slabs for manholes and similar articles with plain faces
M&L screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:4.
M&L for rendering 10 mm thick screed bed on fair faces of brickwork surfaces in CM 1:3 to receive wall finishes.
M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.06sqm but not exceeding 0.11 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
M&L coloured glazed ceramic tiles 200x 300x7 mm thick, in vertical surfaces, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
S & F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F Mild steel screw bolts(11 mm to 15mm dia) (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
S & F Mild steel screw bolts(20 mm dia) (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
S & F Fe 410-W(Gde-E250) Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connectings plates
M&L including preparing of new plastered surface and applying two coats cement base paints on walls.
M & L including preparing of new plasterd wall surfaces and treated with three coats of white wash on it.
M&L for R.C.C 1:2:4 type B1 nominal mix (using 20mm graded agg) as slab supported on walls, beams and colums as directed.
M&L for M.S. TMT bars 8 to 10 mm dia bent to shape required including cranking bending and binding with M.S wire not less than 0.9mm dia complete all as specified and directed.
M&L for preparation of new steel surface over 10 cm with or grith and applying two coats of synthetic enamel paint over a coat of redoxide complete all as specified
M&L for steel ventilators with top hung shutter including hinges steel peg stay, complete
S & F for 3.00mm thick sheet figured glass, pin head type and glazing with oil putty in square n exc 0.50.m in each pane.
Use and waste to formwork to sides of concrete foundation,footing bases of coloumns,raft and raft beams,sides and soffit s of foundation and plinth beam and similar work ; vertical or to batter.
Use and waste rough finished formwork to sides of square column, pillars etc of rough finished surface complete all as specified
Use and waste rough finished formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
S & F 500 litre capacity ,rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) in position all specified in SSR Part –I
M & L Ball valves (20 mm) high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms/ 50mm-1240 gms)
S&F 20mm dia stop cock of PTMT any colour high pressure screwed for iron pipe and fixed.
S & F 15mm bore medium grade tubes, galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors.
S & F 20mm bore medium grade tubes, galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors.
S & F 25mm bore medium grade tubes, galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors.
S&F Vitreous China wash basin, white, flat back, size 550x400mm (flat back or angle back type) including brackets, cutting for and pinning 'in brackets waste coupling, waste pipe, grating complete
S&F Vitreous china squatting pan, Orissa' pattern size 580x440 mm white with integral foot rests including connection to drain pipes and to flushing pipes antisy phonage pipe etc excluding flushing cistern incl flush pipe, jet and seat cover complete as as specified and directed
S & F 15mm bore bib taps, chromium plated cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S & F 15mm bore stop valves/angle cock, fancy type, chromium plated cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S & F cast copper alloy urinal spreader for fixing with 15 mm dia pipe complete all as specified and directed
S & F brass chromium plated tubular towel rail 20mm dia
S & F brass chromium plated toilet paper holder complete all as directed by EIC
S&F PVC connections 15mm size with PTMT nuts of length 300/450mm
S&F Vitreous China Urinal, Half stall type, white (back or corner wall type) complete incl providing and fixing plugs beding urinal against wall in cm 1:2 security urinal plug with and incl 60mm long brass screws pointing around urinal back in cement fixing automatically flushing cistern with bracket, flush pipes grating and union for discharge pipe complete.
S & F 10 litres PVC Syphonic action type, Flushing cistern, high level, with inlet, ball valve, float chain and pull incl flush pipe32mm dia and brackets complete.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
M&L for PCC 1:3:6 type C1 as in concrete bed to drain pipe incl packing under haunching against the sides of pipes after are laid and tested for 150mm dia pipe.
S & F 75mm bore PVC ( SWR) pipes single socketed ,in any length with rubber ring joints, fixed to wall.
S & F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S & F PVC (SWR) bends of radius 75mm bore.
S & F PVC (SWR) junction single,(Single T) equal or unequal of radius 75mm bore.
S & F PVC (SWR) vent cowl 75mm bore.
S & F 110mm bore PVC ( SWR) pipes single socketed ,in any length with rubber ring joints, fixed to wall.
S & F 110MM PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S & F PVC (SWR) bends of radius 110mm bore.
S & F PVC (SWR) junction single,(Single T) equal or unequal of radius 110mm bore.
S & F PVC (SWR) vent cowl 110mm bore.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rein forced with M.S. square tube supplying and fixing in opening as per specification and drawing.
M&L for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plaincolour PVC© channel PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock and bottom rail on either side as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded. Sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing.
S&F Butt hinges, medium weight cold rolled mild steel and fixed as 100mm long.
S&F Aluminium anodised barrel tower bolts of extruded section and fixed as 200mm long
S&F Aluminium handles cast type anodised 150mm long and fixed as complete
Cutting existing steel tubing for alterations or additions( Each cut measured) necessarily done in position without taking down
Cutting holes into or through brick walls built in cement mortar area n exc 150 Sqm cm
Returning, filling in, including spreading leveling watering and well ramming in layers n,exc 25 cm thick in soft /loose soil for sewage pipe line /manhole and cleaning the site.
Removing excavated materials(Soil) n. exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point
Surfaces excavation n-exc (not exceeding) 30 cm deep and averaging 15 cm depth and getting out in soft/loose soil.
M&L for PCC, 1:2:4 type B1,(using 20mm graded cr stone aggr in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed by Engr in Charge.
M&L for sand filling under floor or below paver blocks incl. watering and consolidation.
M&L for Coloured Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement slurry and no pigment complete all as specified and directed.
M&L for Coloured Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade with grey cement slurry and no pigment complete all as specified and directed.
M&L for RCC 1:1.5:3 type A1(nominal mix, using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete
M&L for RCC 1:2:4 (nominal mix, using 20mm graded crushed stone aggregate) as in columns, pillars etc complete all as specified and as directed.
M&L for RCC1:2:4 (nominal mix, using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete
M&L for RCC1:2:4 (nominal mix, using 20mm graded crushed stone aggregate) as in plinth beams, roof beam, cantilevers, lintel beam etc
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips .
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
S&F for steel work in tubular trussess /posts including special shaped washers etc complete using ERW or including butt welded tubes confirming to IS 1161 - 1979 grade St -240 ( using m s pipe medium grade)
M & L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, lain angle cleats for securing purlinsdrilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0
M*L for 100mm thick cement concrete 1:2:4 type B-2 (40mm graded stone aggregate) as in floor finishes laid in panels and finished even and smooth without using extra cement complete all as specified
S&F 25mm dia gate metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
M&L extra for forming fair finished drain or channel any girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc
S &F flat iron for Wind ties for roof including securing bolts including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165
Excavating post holes (or similar holes ) each n.exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus soil to a distance n exc 50m and making good surface
S& F 0.63mm Galvanised, plain mild steel sheeting in ridges, hips, velley gutters, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275.
S& F 0.63mm Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275.
M & L for plain cement concrete type-C2 1:3:6 (40mm garaded agg.) in surface channel and drains
S & F for 5.00mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.50.m in each pane.
S & F 100mm medium weight ,cold rolled mild steel butt hinges.
S & F 200mm long aluminium anodised barrel tower bolts, extruded section and fixed
S & F 150mm aluminium handles, cast type, anodised
S&F pressed steel frame size 150x60 mm for doors with one or more rebates including neccesary fixing lugs, hinges, lock strike plate etc complete all as specified
S&F 1mm thick Mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched including round headed screws, clout nails or rivets and fixed to doors or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred andles etc complete all as specified
S&F for steel windows,with side hung shutters incl projecting type hinges with steel handle and steel peg stay complete with glazing bars, dove tailed or welded complete all as specified
S&F steel ventilators with top hung shuteer including hinges, steel peg stay complete all as specified and as directed
M&L for machine cut kots stone slab flooring 20-25 mm thich over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed
Ditto as in item no 106 above but in riser of steps, skirting complete
E/M PORTION
Taking down down/dismantling old/rusted/broken steel poles/struts,removing from site and making good disturbed surfecs complete.
Taking down down/dismantling old/rusted/deshaped cross arms/MS channel or angle for reuse.
Dismantling insulators any type, any size including setting aside serviceable and removal of rubbish material.
Dismantling of ACSR conductors of any description,stacking serviceable conductor aside for reuse and removing unsv/broken conductor.
Dismantling stay assembly complete including demolition of concrete, etc. and excavation.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all as specified.
Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chromium and two coats of synthetic enamel paint all as specified.
Supplying, transporting, erecting in truely vertical steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts,nuts and screws as specified, including necessary excavation and earth work, PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C-1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surfaces of steel tubular poles with two coats of Aluminium paint and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint of yellow colour and 2 bands with black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Supplying, straining and stretching of Over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and coloured sleeved jumpers with jumper connections with PG clamps complete all as specified.
S&F Insulator Pin type, porcelain, vitreous, white, brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washres and one galvanised iron nut, 100 mm height, 65 mm dia. For 1100 volts grade complete all as specified.
M&L for Stay Assembly comprising of 7/2.24mm galvanised MS stranded wire of required length fixed to pole with and including flat iron clamps fabricated out of 50x6mm flat iron and nuts,bolts & washers of suitable size, 40cms long 14mm dia galvanised MS stay bow, 215cms long 20mm dia stay rod with threaded end including bolts & washers, MS stay plate galvanised 230x230x6mm, two thimbles,loop type insulator of size 65x90mm with clearance dia of hole 20mm including necessary excavation, earth work and PCC 1:4:8 type D2 using 40mm stone aggregate complete all as specified and directed.
S&F insulator shackle type, Porcelain vitreous, white, brown, white or green including, galvanised mild steel straps washers, insulator bolts, washers and nuts, 100 volts working pressure, 75mm height, 90 mm Maximum dia with 31x3 mm galvanised steel straps and dia of bolt 12 mm complete all as specified.
S&F insulator loop type, Porcelain vitreous, white, brown, white or green of size 65mmx90 mm and clearance of hole 16mm complete all as specified.
S&F Danger notice plate 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red color and fixed with M.S. clamps, bolts and nuts, of approved size, for LT, 20x15 cm size complete all as specified.
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of following sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
70 Sq mm cross sectional area, 3½ core.
95 Sq mm cross sectional area, 3½ core.
120 Sq mm cross sectional area, 3½ core.
150 Sq mm cross sectional area, 3½ core.
185 Sq mm cross sectional area, 3½ core.
Supplying and fixing Galvanised mild steel tubing, light grade of following bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately)
50 mm bore
80 mm bore
Supply, installation, testing and commissioning of 12.5 mtr galvanised high mast pole in sections jointed by telescopic slip joint,hot dip galvanised inside & outside, polygonal shape, pole sheet thickness 3mm,top dia minimum 100mm and bottom dia minimum 310mm, base plate not less than 25mm thick, suitable for asymmetrcally loaded 08 lanterns LED flood light fittings with , symetrically fitted along with their driver and having 3 point suspension system with stainless steel wire rope of 6mm dia stainless teel grade 316/304 of 7/19 guage without any intermediate joints and double drum winch, integral power tool with motor installed inside base compartment for operation, manual handle, luminnaire mounting arm or carriage, pully assembly, mounting arrangement for twin red LED aviation obstruction light of 36/40 watt,connector/terminal set fitted inside the mast for cable connection, multi core flexible power cable as per manufacturer's recommendation including making all electrical connections, earth bolt at base compartment,foundation bolts manufactutred from special steel along with nuts, blots, washers of recommended size and length comprising of anchor plate with high tensile studs,lightning arrester spike type and grouted in RCC pedestal foundation in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) or as per manufacturer's design based on soil bearing capacity including excavation and earth work,returning filling & removal of surplus excavated soil of any type as directed at site and suitable for wind velocity of Charduar of Tezpur area & maximum wind speed as per 1S:875 Part-3 all as specified and directed.
Note for Ser Item no 128: (i) the installation, fittings and accessones shall directly be purchased and installed under the supervision/ instructions of original manufacturer or as directed by GE. (ii) Necessary approval of detail technical specifications and foundation drawing of high mast light must be taken before placing the order. (iii) LED flood light, foundation, foundation bolts & aviation obstruction lights shall be measured and paid separately.
Supply and fixing LED flood light 200 watts 6000K complete including making necessary electrical connection and testing all as specified and directed.
Supply and fixing LED aviation obstruction light 36/40 watts 6000K complete including making arrangement to fix these light so as to twin in connections including necessary fixing arrangement and nut,bolts & washers etc. and necessary electrical connection and testing all as specified and directed.
Supply and fixing foundation bolts manufactured from special steel alongwith nuts, bolts, anchor plate and high tensile studs all as specified and directed.
M&L for cement concrete in PCC 1:3:6 type C-1 using 20mm graded stone aggregate including necessary form work for errection of 12.5 mtr high mast pole as per manufacturer's design all as specified and directed.
LT Feeder Pillar Box both side openable with projected globe roof for rain water protection,CPRI approved,dust and vermin proof, suitable for 440 volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet of size 0.75MX0.75MX0.50 Mtr and mounted on rigid frame of MS angle iron of suitable size, having front and rear hinged double shutter doors with neoprene rubber gasket, epoxy power coated, danger notice plate with conventional sign of bone & skull, earthing point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. and embeded in and including PCC at height of 600mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation complete all as specified and comprising of the following :-
Note for Ser item no 133 : (i) Aluminium bus bar 100 Amps mounted on heavy duty porcelain insulators with suitable nuts,bolts and washers and heat shrinkable PVC sleeves colour coded for three pole and neutral. (ii) MCCB 63 Amps 4 pole, 25 Amp, 415 volt, 35 KA breaking capacity, Adjustable range 40% to 100%) duty connected to bus-bar as in incoming - 01 Nos . (iii)MCCB 63 Amps 3 pole, 16 Amp, 415 volt, breaking capacity, Adjustable range 40% to 100%) duly connected to bus-bar as out going-02 Nos (01 for motor and 01 for light). (iv) Digital Ammeter 0-100 Amp with 3 No. CTs-01 Nos (v) Digital voltmeter 0-500 volt-01 Nos (vi) LED indicating lamps (3 Nos.) with holder for main supply indicating RYB - 01 set (vii) Instument fuse holder, fused 4 amp (viii) Astronomical time switch 20 amps 24 hour programming type 230 volt, auto manual switch, bypass switch for time switch, ML-3, 40 amps, 415 volt three phase contactor, coil operating voltage 230 volt incl necessary internal wiring and fuse protection for automatic ON/OFF of security light - 01 set (ix) Contactor MNX-32 three phase 415 volts with coil operating voltage 230 volts-02 Nos with 2 Nos push button switch 16 amps and electrical interlocking between two contactors for farward and reverse operation of motor installed at high mast system including necessary connection.
Supplying, laying or fixing, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE Cable) insulated, 16 sqmm 4 core, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade og following sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block and pipe shall be measured and paid separately under appropriate items).
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all as specified.
Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified.
Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified.
S&F in repair, connecting, testing and commissioning of MCCB 200 Amps, 4 Pole,36 KA 50 Hz with thermal magnetic setting adjustable type in existing panels/sheet metal enclosures including suitable size aluminium lugs/thimbles, nuts, bolts & washers etc complete all as specified and directed
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate to less than 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thikcness of 15 cm connected to GI earth strip of size 25x4mm means of nuts, bolts and washers to earth plated at one end and other end to contineous GI wire of OH lines/lighting arrestor or street light poles etc,checknuts of GI and protction by the GI pipe light grade 15 mm nominal bore for earth lead wire from earth plate to 1500 mm above GL with FI clamps made out of 25x3mm fitted with nuts, bolts and washers and 2.5 m long watering pipe light grade of 20 mm nominal bore , 0.63 mm thick CI funnel, wiremesh, etc. complete including necessary earth work and excavation in soft/loose soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100 mm c/c both ways, earth phophrous bronze testing point , maing good etc. all as specified and shown in electrical plate of SSR- Part-I.
M & L for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade drawn in and including rigid PVC concealed conduit ISI mark with all accessories (size of concealed conduit as required at site but not less than 20 mm), and PVC box as required at site for mounting switches, sockets, regulators, etc. complete with all fittings and accessories fixed to wall/ceiling for one light/fan point controlled by one switch including 1.5 sq. mm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed for one light/fan point controlled by one way switch
M&L wiring for one 15 amps power point on independent board using 1.5 Sq mm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated sheathed drawn in and including PVC casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed recessed boxes of required size factory made for mounting of switches/sockets etc and1.5 Sq mm nominal cross sectional area multistranded FRLS copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc. complete all as specified.
Supply & fixing switch piano, flush type, and 5/6 amps, 240 volts, single pole, one way complete all as specified and directed
S & F lamp holder, insulated body, with back plate straight or angular type suitable for batten fittings complete all as specified and as directed
S & F LED Bulb 10 Watt Glass type all as specified and as directed
S&F sheet metal enclosure MCB DB double door 2 ways with 200 Amps rated bus bar SPN complete all as specifed and direcetd.
Supply & fix MCB single pole (SP) 6 to 32 amps, 240 volts, 10KA, ‘B’ series complete all as specified and directed
Supply & fix MCB SPN single pole and neutral 6 to 32 amps, ‘B’ series complete all as specified and directed
Material and labour for house service bracket (hook type) complete with 3.0 m long GI pipe of size 40mm dia, medium grade, two No 90 degree bends MS hook and stay or guy complete all as specified and as directed
Supply and fixing for one twin core cable flat or circular 1100 volt grade, heavy duty cable of size 4 sq.mm PVC insulated aluminium stranded conductor, served with inner sheathing of PVC 10 Sq.mm sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm suspension wire, one twin core flat or circular complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point & to main switch board with and including adequate quantity of charcoal dust and common salt all-round earth plate and 15mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit and 40 mm thick pre-cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cover with 3 Nos 8 mm dia TMT bars both ways and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed.
S&F LED bulk head 10 watts 6000K with opal diffuser including making electrical connection.Ordering code LHEOAAOP7UZ6W010 of Havells or equivallent in Philips/Bajaj
S&F ventilating fans non metallic range AC single phase 240 V of size 200mm with lower complete with all accessories prewired twin core twisted flexible copper conductor cable including making necessary niche with mounting bracket all as required at site and electrical connections all as specified and directed.
M&L single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps including making necessary electrical connections all as specified and directed by Engr-in-charge
Supply. Installation, testing and commissioing of water heater storage type, operated of capacity 25 litres, 5 star rated, having stainless steel body with PUF insulated steel tank, thermostat, thermal cutoff, glass coated heating element of 1.5 KW, vertical type with reset option including making all electrical and water supply connections of inlet and ouitlet points with suitable PVC pipe of suitable length and suitable for hot and cold water as required at site including neccesary nuts, bolts and washers of required size all as specified and as directed
M&L CP mixer for mixing hot and cold water screwed down for galvanised iron pipe and making connection all as specified and as directed
S&F GI tubing medium grade 25mm with all fitting and fixed complete to walls and ceilings or laid in floors trenches all as specified and as directed
M/S Yadav Corporation
M/S JALALUDDIN AHMED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .