Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC QUOTEED AMOUNT IS LOWEST AND RESONABLE | |
| 2 | L2₹34.8 L+₹2.3 L (6.99%)Rejected-Finance VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 3 | L3₹35.1 L+₹2.6 L (7.90%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 4 | L4₹35.6 L+₹3.1 L (9.41%)Rejected-Finance | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 5 | L5₹35.6 L+₹3.1 L (9.47%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE |
Tender Value
₹34.7 L
EMD Value
₹69,480
Closing Date
23 Sept 2024, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
PROVN OF 05XNEW WATER COOLERS 180 LTRS FOR ALL COY TRG AREA AT SRC PROVN OF 25 KVA CAP DG SET ALONGWITH PLINTH 8FTX10 FT OVERHEAD AT BLDG NO P-564 NEWLY CONSTR NE LIB AT RECORDS THE PRC, PROVN OF 02XHIGH MAST LIGHTS AT TRG AREA OF THE PRC RAMGARH
2024_MES_668103_1
8300/3261/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹69,480
Yes
4 Dec 2024
31 Aug 2024
28 Sept 2024
31 Aug 2024
23 Sept 2024
14 Sept 2024
Amount
.(A) SUPPLY PART OF 16M HIGH MAST SYSTEM :- Supply of Galvanized steel high mast lighting system of 16 meter shall be in two sections, hot dip galvanised inside and outside in single dip, suitable for wind velocity as per IS 875Part-III, 3 mm section thickness, top dia 150 mm, bottom dia 340 mm, with complete motorized rope system with 08 nos 120w LED flood lights. There shall be only one longitudinal seam weld per section and no circumferential weld. It shall also include accessories for high mast including head frame, two point suspension system with steel wire rope 6mm dia (7/19 construction) double drum winch, galvanised lantern carriage arrangement suitable for 8 luminairies LED type symmetrically & lightening finial. The mast shaft have an internal type power tool mounted at the base compartment for its operation . It also comprises the following :- (i) Foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates Qty- 01 Set. (ii) LED 120w LED flood lights Qty - 08 Nos. (iii) Twin dome aviation LED light Qty - 01No. (iv) Control pannel housing suitable control circuit for automatic switching ON and OFF of the mast. It shall also have suitable controls for operation of Power Tool Qty -01 Set. (B) ERECTION PART :- (i) Construction of suitable shallow foundation with design mix 'M25' concrete for the high mast considering the safe soil bearing capacity at site as 10T/Sqmtr at 2 mtr depth with all material & labour Job-01. (ii) Erection of the high mast with the help of suitable equipments and wiring of luminaires with all wiring material & labour Job-01 No (iii) Installation of control panel on suit abvloe foundation including all matertial & labour Job-01 (C) TESTING & COMMISSIONING COMPLETE:- (i) Testing & Commisoning of above high mast system complete. Note: Rate quoted against this item deemed included all three parts mentioned above.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh,charcoal dust and common salt 15cm in layers all round the earth plate, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally and chamber of (size of pit 300 mm x 300 mm x 300mm internal diamentions) PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old/ unserveciable existing earthing & making good disturbed surface of wall ,floors etc.complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sqmm 4.0 core complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 0.45 metre deep and not exceeding 0.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering & well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, complete all as specified and directed by the Engineer-in-Charge.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supply, laying , jointing & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm ,3 core, 1100 Volts grade complete all as specified and directed.
Supplying, installation, testing and commissioning factory assembled of silent type Diesel Engine, corrosion resistant in modular construction, epoxy coated base proof epoxy coated base frame enclosure silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per BS5514/IS 10002 directly coupled to AC Alternator capable of developing 25 KVA/ 20 KW at 1500 RPM at 415V 50 Hz, 0.8 pf (lag) generally meeting the reqirement of IS 13364 inclusive of power control panel (microprocessor based fully configured) to regulate the AC power, 12 V electric starting system 88 AH battery complete with relay panel and switch gears for automatic starting on main failure with standard AMF panel configured inside the genset body, control panel having meter and sound proof canopy as per CPCB II norms, doors must be gasketed with high quality EDPN gasket and durable industrial locking system, emergency push button to stop the DG set from outside, Lub oil level, lub oil pressure, coolant level with over load relay protection, earth fault relay protection & under voltage protection of capacity 25 KVA complete all as directed. Note : DG Set must comply Gazette of India notification No. G.S.R. 771(A) dated 11 Dec 2013 or its latest amendment till date.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
Supply and laying for 40 mm dia HDPE pipe of pressure rating 6 Kgf/sq.cm fixed with all necessary fittings for cable protection in walls, ceiling, floors, road etc complete all as specified and directed by Engineer-in-Charge.
M & L earthing complete with Gl electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X6 mm as earthing leaad by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x6mm mild steel angle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @ 75mm C/C both way with mild steel handle 12 mm dia round bars ,10mm thick plastering with cement mortar (1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed.Note: Earth strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 150 litre and nominal cooling capacity of 150 Litres per hour complete all as specified and directed..
M&L for point wiring FRLSH cable PVC for the 15 amp 3/5 pin socket power point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 2.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
S&F Switch socket combination 2 in 1, 3 pin, 5 amp & 15 amp flush type universal, complete all as specified and as directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors/trenches including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F 15mm dia bore stop valve cast copper alloy fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle screwed bot ends for iron pipe or for unions complete all as specified and directed
S&F PVC connections 15mm size with PTMT nuts of length 375 mm complete all as specified and directed.
S&F double door SPN DBs metal enclosuresl, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts with suitable amps copper rated busbar 4 way complete all as specified and directed by Engr-in-charge
S&F miniature circuit breaker (MCB) 240V ,10 KA 'B' curve of single pole and current carrying capacity 5 Amp to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
S&F miniature circuit breaker (MCB) 240V ,10 KA 'B' curve of single pole & neutral (SPN) and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
M&L for cutting of existing GI pipe for insertion of Tee for new branch connection including necesary fittings and cutting of brick masanory wall suitable for 15 mm dia GI pipe and making good to the distubed surface of wall as per existing complete all as specified and as directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 06 Sqmm 2.0 core complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) in soft /loose soil not exceeding 0.5 cum, getting out, & removing surplus soil (material) to a distance not exceeding 50 mtr & making good surface complete all as specified & directed.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M&L for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring & mass concrete etc complete all as specified and directed.
M & L for 50 mm thick PCC (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate ) as in floor finishing , even & smooth using extra cement including fixing of glass strip as per design as directed by Engineer-in Charge complete all as specified and directed. Note: Glass dividing Strip shall be measured and paid separately.
Supply only 38 mm wide glass dividing strips,3.0mm thick inserted in position,conform to design complete all as specified & directed.
M&L for plain cement concrete 1:3:6 ,type C-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L for fly ash Brick work with using sub class "B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M&L for 15mm thick rendering on stone masonry surfaces or brick work or concrete surface in cement mortar 1:4, finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plaster surface wall and applying two coats of cement base paint over a coat of alkali primer including necessary scaffolding complete all as specified & as directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed.
S & F for 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges,hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified and directed.
S & F 110 mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed on wall including PVC clamp properly with PCC 1:2:4 complete all as specified and directed
S & F PVC (SWR) bends 110 mm bore of any radius complete all as specified and directed
S & F rolled mild steel sections as in framed structure with main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and fixed with angle cleats or other connecting plates, mild steel angle, flat iron ,Z- sections(ISI mark) conforming to Gde Fe-410-0 or Fe 310-0 complete all as specified & directed.
M/S ROHIT CONSTUCTION (BID ID -3105499)
upadhyay engineers and consultant (BID ID -3105572)
M/S Bhushan Kumar Jain (BID ID -3106588)
M/s friend enterprises (BID ID -3105543)
ranjit singh (BID ID -3105605)
Raj Construction (BID ID -3103013)
M/S tiwari enterprises (BID ID -3102906)
M/s Ray construction (BID ID -3107237)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .