Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.2 LAccepted-AOC | 1 | Accepted-AOC KSEBL decided to award the work to lowest qualified bidder | |
| 2 | 2₹33.4 L+₹2.1 L (6.86%)Rejected-AOC | 2 | Rejected-AOC second lowest bidder |
Tender Value
₹33.5 L
EMD Value
₹50,000
Closing Date
9 Sept 2024, 11:00 amClosed
Chief Engineer_Civil_Dam Safety and DRIP
Deputy Chief Engineer with full powers of the Chief Engineer Civil Dam Safety DRIP Dam Safety Organization Pallom Kottayam
DRIP II- SGHEP -Construction of Cat walk bridge to access the trunnions of the radial gates at Pamba dam
2024_KSEB_683276_1
KL KSEB DRIP II /SGHEP/Pamba catwalk/CE- 10/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
Kochupamba
see tender documents
3 documents required · 3 mandatory
₹5,900
₹50,000
Yes
22 Nov 2024
9 Aug 2024
9 Sept 2024
9 Aug 2024
9 Sept 2024
9 Aug 2024
9 Aug 2024 - 17 Aug 2024
Amount
Civil works
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
Supply and fixing weld mesh of size 50x50 mm or nearest size cost including welding charge, fitting all necessary nut and bolt, labour charge and 2 coats of any premium synthetic enamel paint of make and colour as approved by the departmental officers.
Supplying and fixing Hilty bolt HIT-RE500V4 with HIT-V Threaded Rod.The product should be approved by ETA, ICC, CSTB, COLA, BZS with shock approval, seismic (C1&C2)approval, Fatigue and Fire approvals in anchors to use in cracked /un- cracked concrete, tested for service temperature of - 40 deg.C to +80 deg.C. The chemical should have an ETA approval for 100 years age testing and EJ document of 120 years age.Anchoring with HIT-V with RE500V 4 to be designed as per guide lines of TR 029/EN 1992-4. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air or with Safe set Hollow Drill Bit technology to ensure dust free clean holes and proper bonding of chemical to the required depth, filled with epoxy grouting,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufactures recommendations and as per direction of Engineer in charge.HIT- Re 500v4 with Anchor rod HIT- V-5.8M20X300mm at 200mm depth
Supplying and fixing Hilty bolt HIT-RE500V4 with HIT-V Threaded Rod.The product should be approved by ETA,ICC,CSTB,COLA, BZS with shock approval, seismic(C1&C2)approval, Fatigue and Fire approvals in anchors to use in cracked /un- cracked concrete, tested for service temperature of - 40 deg.C to +80 deg.C. The chemical should have an ETA approval for 100 years age testing and EJ document of 120 years age.Anchoring with HIT-V with RE500V 4 to be designed as per guide lines of TR 029/EN 1992-4. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air or with Safe set Hollow Drill Bit technology to ensure dust free clean holes and proper bonding of chemical to the required depth, filled with epoxy grouting, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufactures recommendations and as per direction of Engineer in charge<br>HIT- Re 500v4 with Anchor rod HIT- V-5.8M16X260mm at 200mm depth
Finishing steel work with two or more coat of Aluminium paint of approved brand and manufacture to give an even shade over a second coat of ready mixed zinc chromate primer ( Aluminium painting should be done over two coat red oxide zinc chromate primer in which one coat is paid separately with steel work)
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level-Hot rolled deformed bars
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Supply and installation of working platform along the area in which the catwalk is to be installed including all charges for supply, installation as well as shifting to necessary positions as needed and including all costs for scaffolding work ,labour etc. complete.
Santhosh vj
Bidder Name
Santhosh vj
RAJEEV VR
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .