| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | ₹1.0 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.0 Cr+₹11,559.33 (0.11%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹1.0 Cr+₹11,559.33 (0.11%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.2 Cr+₹12.8 L (12.3%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹1.2 Cr+₹12.8 L (12.3%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹1.2 Cr+₹14.3 L (13.7%)Rejected-Finance PILIBHIT BYE PASS NEAR GURUNG GAS GODOWN BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹1.2 Cr+₹14.3 L (13.7%) | L4 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Shikhar ji Enterprises L1 | GUPTA ENGINEERING WORKS L2 | Garg Construction L4 | Roy and Sons Infrastructures L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, installing, testing & commissioning, factory assembled Diesel Engine driven generating set Silent as per CPCB - IV+ Norms, coupled with AC alternator to give continuous output of 125 KVA at a PF of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine Liquide cooled mounted on common base frame complete with inbuilt fuel tank of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions,vibration damper pads, control panel showing all parameters of engine,alternator , sound proof canopy & other accessories etc. and suitable for autometic operating on mains failure complete comforming to the undermentioned technical specifications complete in all respect and all as specified and directed. | 5 | Each | 16,40,000 ₹82,00,000 | 16,25,000 ₹81,25,000 Lowest | 18,40,000 ₹92,00,000 | 18,00,000 ₹90,00,000 |
| 1.01(A) DIESEL ENGINE : 4/6 Cylinder Air cooled to deliver 154-162 BHP at 1500 RPM under NTP conditions and conformimg to ISO 9001/2015 with an overload capacity of 10 % for one hour during 12 hrs continuous operation with the following accessories (a) Blower fan or heat exchanger with guard (b) Pipe coupling for engine cooling system piping (c) Corrosion inhibitor coolant (d) Paper element filters for (i) Fuel (ii) Lube oil (iii) By Pass (e) Fly wheel housing and fly wheel to suit alternator | |||||||
| 1.02(f) Engine bearing mechanism in fly wheel housing (g) Shut off coil with safeties for LLOP/HWT/over speed (h) Dry type air cleaners and vaccum indicators (j) Residential silencers (k) Stainless Steel exhaust flexible bellows (l) Motor driven priming pump (m) Battery charging alternator (n) Exhaust piping made out of STIC C class , MS pipe inclusive of all accessories and hardware, necessary support scaffolding as per manufacturer's recommondations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheet of 30 gauge for the entire length of exhaust pipe (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing (q) Interconnecting copper cabling of adequate capacity between batteries and controller (r) Fuel pipes as per manufacturing standerd (s) Self starter 12 volt D.C. (t) Mechanical governor (u) Fuel injection pump (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) Battery voltage and charging rate (ii) Water temperature (iii) Lubricating oil pressure (iv) Engine speed (v) Engine hours (vi) Frequency (vii) Voltage (viii) Fuel Balance | |||||||
| 1.03(w) Safety control ( Trip and indication ) (i) High water temperature (ii) Low lube oil pressure (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) fabricated from ISMC 100 channel for mounting engine and alternator as per manufacturer's design alongwith AVM pads (y) Battery:- 2 Nos, 12 Volt, maintenance free battery with leads and terminals. (z) Fuel Tank : Inbuilt Fuel tank, with level indicator fuel inlet ,fuel out let, air vent, drain plug, in let arrangement for diesel filling from exterior of canopy (without opening its panel) etc. complete all as specified and directed. | |||||||
| 1.04(B) ALTERNATOR: 125 KVA at 0.8 PF ,415 Volt, 3 Phase, 4 wire, 50 Hz , 1500 RPM , Self excited and self regulated +-1% with AVR brushless excitation, screen protected, drip proof, Insulation class H, IP-23, self ventilated and conforming to BS : 5000 / IS: 4722 suitable for engine as mentioned here-in-before (C) ACOUSTIC ENCLOSURE: Factory Made acoustic enclosure as per OEM's recommendation | |||||||
| 1.05(D) CONTROL PANEL : The control panel shall be manufactured by 2.0 mm thick CRCA sheet duly 7 tank process powder coated dust and vermin proof, weather proof and comprising the following:- (i) Standerd Engine instrumentation (ii) Multifunction meter which able to measures (a) Individual phase current (Amps) (b) Phase Voltage (V) (c) Generator out put fequency (Hz) (d) Engine Water temperature (Deg. C) (e) Lube oil pressure (Kg/cm2) and equipped with hour counter (iii) MCCB 4 pole, 415 Volts, 200 Amps rating, rupturing capacity 25 KA thermal magnetic release,adjustable over load (0.7 to 1), Standard control panel with micro processor controller with engine satelites and protection, sound proof canopy with residencial silencer, fix with overload & short circuit, (iv) Key switch (v) Push button (Starter) (vi) LED : Battery charging alternator fail indication (vii) Current transformers (viii) Instruments fuse duly wired and ferruled | |||||||
| 1.06(E) CIVIL WORKS: (i) All civil works related to suitable size of platform made by PCC 1:2:4 as per OEM specifications for installation of DG Set panel and equipment are deemed to be included in to quoted rates. Note:- The fuel for final testing of 12 hours as well as all test required shall be supplied by the contractor and cost deemed to be included in the above quoted rate. All other necessary equipments like resistance load strip heater of suitable capacity/rating or arrangement of water load test and any other items required for final testing shall be provided by the contractor without any extra cost to Department. The testing of DG set shall be carried out by the rep of Accepting Officer. | |||||||
| 1.07(F) AUTOMATIC MAIN FAILURE (AMF) CONTROL PANEL: Out door type ,factory fabricated cubical type ,free standing ,floor mounted , AMF control panel ,provided with removable rear panel & hinged front panel for easy accessiability ,fabricated out of not less than 3.15 mm thick CRCA Sheet including of powder coated paint and comprising of :- (i) Standard control panel with micro processor controller with engine satelites and protection, sound proof canopy with residencial silencer, MCCB 4 pole, 415 Volts, 200 Amps rating, rupturing capacity 25 KA thermal magnetic release,adjustable over load (0.7 to 1) and short circuit protection,IS 13947-2/IEC 60947-2.(1 No each for commercial & DG supply ) (ii) AMF control circuit with HRC back up fuses complete with all DC control relays/line voltage monitor (LVM) as per OEM specifications incorporating engine start, stop, three attempt starting facility and failure to start etc. | |||||||
| 1.08(iii) Digital frequency meter . (iv) Digital power factor meter (-1.0 to + 1.0) (v) Indicating lamps for supply " ON" and Load "ON" (vi) Instrument fuses (HRC type) suitable size. (vii) Push button 01 No each for start, stop & reset (viii) Electrolyte copper busbars PVC colour sleeved 300 Amps capacity TPN mounted on hygroscopic insulator duly colour coded RYB & Green sleeves (ix) Circuit diagram plate (x) Automatic battery charging unit including facility for over charging stop/trickle charging / boost charging 12 volt complete with DC ammeter, DC voltmeter, charging set selector switch. (xi) Facility for remote / auto start, auto / manual sychronizing, audio-visual announciation and indication lamps for engine faults. | |||||||
| 1.09(xii) LED phase indicating lamps for RYB with controlling fuses - 02 sets. (xiii) Digital Ammeter 96 sq.mm 0 - 200 Amps with suitable CT's -01 set (xiv) Digital volt meter 96 sq.mm 0 - 500 volts -01 set (xv) Power contractor 4 pole, AC 415 volts, 50 Hz, -02 Nos. (xvi) Any other accessories componenets required for autometic operation on mains failure/ restoration as per manufacturers instruction/manuales. Notes :- (i) The AMF Panel shall be fabricated by CPRI approved factory from the attached list of make. The necessary certification shall be furnished by the contractor. The constructional drawings, make of switch gear and hardware, size of panel board, technical specification shall be submitted by the contractor for approval of accepting officer. (ii) Contractor shall arrange inspection for DG set/ AMF panel at factory premises before despatch. The inspection shall be carried out by the nominated rep of accepting officer. (iii) Any civil work involved in installation of panel board deemed to be included in item rate. | |||||||
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
27 Sept 2025, 6:00 pmClosed
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (E) /57 OF 2025- 2026SPECIAL REPAIRS OF DG SET FOR WATER SUPPLY PUMP HOUSE AGAINST BER AND ALLIED WORKS AT VARIOUS LOC UNDER GE (EAST) BAREILLY
2025_MES_726160_1
8200/B/876/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (East) Bareilly
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (East) Bareilly
₹1.9 L
Yes
5 Dec 2025
14 Aug 2025
4 Oct 2025
14 Aug 2025
27 Sept 2025
4 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .