| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC SHARON O2 2 O STREET JAWAHAR NAGAR KOWDIAR THIRVANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | ₹7.5 L | L1 | Accepted-AOC Lowest rate quoted at 26.56 percentage below estimate including GST |
| 2 | L2₹8.2 LRejected-AOC KARTHIKA NIVAS PUNCHAKKARI THIRUVALLAM P O THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | ₹8.2 L | L2 | Rejected-AOC Third Lowest rate quoted at 17.85 percentage below estimate including GST |
| 3 | L3₹8.3 LRejected-AOC | ₹8.3 L | L3 | Rejected-AOC Second Lowest rate quoted at 19.10 percentage below estimate including GST |
Tender Value
₹8.6 L
EMD Value
₹21,511
Closing Date
12 Feb 2026, 5:00 pmClosed
Executive Engineer,PMU ,Kattakada.
O/o Executive Engineer,PMU,Kattakada
LAYING UG CABLE FROM PLANKALAMUKKU TO MALAYAM TAP UNDER ELECTRICAL SECTION, NEMOM
2026_KSEB_831661_1
EE/PMU(KTDA)/ET-18/2025-26 dated 29.01.2026
Open Tender
Electrical Works
120 days
Nemom
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,124
₹21,511
31 May 2026
29 Jan 2026
17 Feb 2026
29 Jan 2026
12 Feb 2026
29 Jan 2026
29 Jan 2026 - 6 Feb 2026
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
Loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle).
Providing one Earth using earth pipe incl. digging & backfilling pit and supply of charcoal, salt, sand etc.
Doing one cable end termination on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally.
Doing straight joint on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally as per specification.
Fitting and erecting one HT DP using A type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP incl. conveyance of materials.
Mounting the cable ends of all sizes upto and incl. 3x300 sq mm with special type cable clamps incl. cost of extra materials if needed and giving necessary connections.
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading.
Excavation of cable trench in all classes of soil and backfilling after laying of cable (excluding laying of cable).
Laying HT XLPE UG cable (of sizes beyond 3x185 sqmm and upto and incl. 3x300 sqmm) as per specification excl. excavation and backfilling.
Drilling hole of various sizes on existing Channel/Cross Arm.
Installation of CTC RMU in existing foundation
Transporting Transformers by hired vehicle upto 5km and upto 2 No. of 63 to 250kVA Transformers / RMUs excluding loading & unloading.
Transporting Transformers by hired vehicle to a distance beyond 5km and upto 2 No. of 63 to 250kVA Transformers / RMUs (Running km).
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1397648.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BID.pdf
Tender Documents • 0.84 MB
BOQ_1397648.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid