Loading…
Loading…
Tender Value
₹4.0 Cr
EMD Value
₹3.7 L
Closing Date
5 Sept 2026, 6:00 pm
Manager
RETROFITTING AND RENOVATION WORK OF PARABAZAR BRANCH OF RNSB, RAJKOT
332341
RNSB/2026-27/10
Open
Civil - All
Works
Rajkot
3 documents required · 2 mandatory · 1 optional
₹15,000
RAJKOT NAGARIK SAHAKARI BANK LTD
₹3.7 L
7 Aug 2026
7 Aug 2026
7 Aug 2026
5 Sept 2026
7 Aug 2026
Providing and laying in position Ready Mixed M-
250 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to site
of work in transit mixer for a lead up to 10 kms
having continuous agitated mixer, manufactured
as per mix design of specified grade for
reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of
laying, INCLUDING the cost of centering shuttering
finishing and EXCLUDING the cost of reinforcement including cost of
admixtures in recommended proportions as per
IS: 9103 to accelerate/ retard setting of concrete,
improve workability without impairing strength
and durability as per direction of the Engineer -
in - charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained) (Cement
Providing and executing complete negative-side confined
waterproofing system to existing basement walls, floor slabs, lift
pits, sump pits and associated underground structural surfaces
including condition assessment, leakage mapping, crack mapping,
cleaning, removal of unsound material, repair of cracks, repair of
honeycombs, repair of voids, treatment of open joints, formation of
polymer modified cementitious fillets, supply and installation of
approved confined waterproofing membrane system, treatment of
laps, corners, penetrations, sleeves, construction joints, lift pits,
sump pits, terminations and changes in plane, protection during
16 350.00 reinforcement fixing, protection during concreting, repair of Sq.mt 800
accidental damage, quality assurance procedures, inspection,
testing, photographic documentation, monsoon protection
measures, preparation of records, rectification of defects before
concealment and all labour, materials, equipment, tools, tackles,
lifts, leads, temporary works and incidental operations complete.AS
PER SPECIFICATIONS MENTIONED IN SPECIFICATIONS BOOKLET
Repair, Strengthening & Facelifting Works ITEM NO. J
Providing and fixing 100mm Thick concrete jacketing (M-25) as per
specifications of Engg
Removing and scraping of old deteriorated plaster of any
thickness from wall / R.C.C member including stacking
18 5807.76 of serviceable material and disposal of unserviceable Sq.mt 300
from site of work with all lead and lift. (Item no. -, Page no. 122)
Providing 15mm Thick Cement Plaster in single coat for Interior
plastering upto all floor level finished even and smooth in Cement
mortar 1:4 (1-Cement : 4-sand) finishing with a floating coat of Lime
neeru etc.complete.
20 mm thick sand faced cement plaster on walls upto height
meters above ground level consisting of 12 mm thick backing coat
of C.M. 1:3 (1-cement: 3-sand) and 8 mm thick finishing coat of C.M.
1:1 (1-cement: 1-sand) etc. complete including all material and
labour as directed by Engineer in charge
Providing and fixing anchor fastners upto 20mm dia with making the
hole of required dia and depth as per supplier specifications using
21 100.00 EPOXY grouting chemical etc complete as per instructions of each 400
engg.(Which are not covered in any completed item)
Providing and fixing anchor fastners upto 20mm dia with making the
hole of required dia and depth as per supplier specifications using
22 100.00 CEMENTIOUS grouting chemical etc complete as per instructions of each 300
engg.(Which are not covered in any completed item)
WATER PROOFING - Terrace water proofing on bare (naked)
23 720.40 concrete floor of liquidnmemberane with net or equivalent any sq.mt 600
other application having minimum 10 years of gurantee
Providing and executing strengthening of existing load-bearing
masonry wall foundations by controlled alternate block
underpinning, foundation widening and composite jacketing system
as detailed in drawings and Section Z-Z, complete in all respects,
including joint inspection, distress mapping, setting out of Zone-1
and Zone-2 blocks, temporary shoring/propping/bracing and all
structural stability measures, controlled excavation in alternate
blocks only, excavation in all types of soil, dewatering and water
diversion, protection of open excavations, cleaning and preparation
of existing masonry foundation, removal of loose mortar,
vegetation, roots and deteriorated material, drilling holes in existing
masonry foundation, providing and fixing 12 mm diameter dowel
bars at 600 mm c/c or as shown in drawings, providing and fixing
mm diameter shear pins/connectors at 600 mm c/c both ways and
both faces or as shown in drawings, cleaning drilled holes, fixing
bars with approved chemical anchoring system/non-shrink
anchoring grout, providing foundation widening on both sides of
existing masonry foundation by plum concrete in 1:3:6 proportion
with approximately 450 mm projection on each side
and in two vertical lifts/blocks of approximately 600 mm + 600 mm
or as detailed, proper placement and compaction around existing
foundation to achieve composite action, repair/filling of local
cavities and voids, selected earth backfilling with watering and
compaction, providing 40 mm thick cement mortar gunite in 1:3
proportion to prepared masonry surfaces, providing 150 mm thick
M15 RCC coping at ground/plinth level including formwork,
reinforcement if detailed, placing, vibrating, finishing and curing,
continuous curing of concrete/gunite/coping, structural monitoring,
monsoon protection measures, scaffolding, barricading, warning
signs, lighting, safety arrangements, disposal of surplus material,
QA/QC documentation, photographs and all labour, materials,
machinery, tools, tackles, leads, lifts, temporary works and
incidentals complete as per specifications, drawings and directions
of Engineer-in-Charge / Structural Consultant. AS PER
SPECIFICATIONS MENTIONED IN SPECIFICATIONS BOOKLET Repair,
Strengthening & Facelifting Works ITEM NO. I
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work
including bending, binding and placing in position complete upto
25 10664.06 floor two level as per the drawing and instruction of Engineer-in- kg 83
charge etc complete FOR ALL FLOORS
Add contigencies and overheads. ADD 15%
I/We _________________________________________________ am/are willing to carry out the above work at ___________________ %
above/below ___________________ percent (should be written in figures and words) of the estimated rate mention above estimated amount of
my/ours tender work out as under.
ESTIMATED AMOUNT PUT TO TENDER ESTIMATED AMOUNT PUT TO TENDER
Total Amount Rs. ________________________ Total Amount Rs. ________________________
Total Amount Rs. ________________________ Total Amount Rs. ________________________
SIGNATURE OF THE BIDDER
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.0_SPECIAL_CONDITION_OF_CONTRACT.pdf
3.0_Specifications_Booklet_withALL_TitlePage.pdf
4.0_SCHEDULE_B_OF_RETROFITTING_WORK.pdf
5.0 Structure Drawing.pdf
1.0_TENDER_-RNSB_RAJKOT_RETROFITTING_WORK__29072026.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].