| Sl No | Description | Qty | Unit | M/S ZAKIR HUSSAIN L2 | M/S M A ENTERPRISES L4 | M/S MOHD HUSSAIN L3 | M/S ADHISH ENGINEERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M & L for checking & repairing Street lights/flood lights/tower lights/highmast lights & other connected work as directed in tech area daily and repairing of lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of cable/lights etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all as specified and directed.
NOTES :-
(i) Rate quoted shall deemed to be included for required minor material like insulation tap/repairing of junction box with lugs etc.
(ii) Items like Driver for LED and other items other than mentioned above will be measured and paid separately.
(iii) Contractor shall provided labour at site for rectification/repair and as per direction of Engr-in-Charge. | 196 | Each Job | 77 ₹15,092 Lowest | 90 ₹17,640 | 160 ₹31,360 | 350 ₹68,600 |
| 2.00Supply and fix in repair Driver for LED lights of as per existing make for the following capacity :- | |||||||
| 3.00 | Driver for 60/70 Watts LED | 46 | Each | 825 ₹37,950 | 900 ₹41,400 | 756 ₹34,776 Lowest | 925 ₹42,550 |
| 4.00 | Driver for 40/45 Watts LED | 80 | Each | 700 ₹56,000 | 800 ₹64,000 | 650 ₹52,000 Lowest | 750 ₹60,000 |
| 5.00 | Driver for 25/30 Watts LED | 70 | Each | 550 ₹38,500 Lowest | 650 ₹45,500 | 600 ₹42,000 | 700 ₹49,000 |
| 6.00 | Excavation in trenches not exceeding 1.5m in depth deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified and directed by Engr-in-Charge. | 405 | Cum | 800 ₹3,24,000 | 850 ₹3,44,250 | 520 ₹2,10,600 | 285 ₹1,15,425 Lowest |
| 7.00 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr-in-Charge. (Surplus soil if any shall not be removed but left over the trench) | 243 | Cum | 176 ₹42,768 | 200 ₹48,600 | 230 ₹55,890 | 45 ₹10,935 Lowest |
| 8.00 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. | 162 | Cum | 400 ₹64,800 | 480 ₹77,760 | 450 ₹72,900 | 55 ₹8,910 Lowest |
| 9.00 | Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified and directed.
Note :- For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I. | 121.5 | Cum | 1,350 ₹1,64,025 | 1,500 ₹1,82,250 | 1,450 ₹1,76,175 | 785 ₹95,377.5 Lowest |
| 10.00 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other at site complete all as specified and directed by Engr-in-Charge. | 10,000 | Each | 60 ₹6,00,000 | 100 ₹10,00,000 | 95 ₹9,50,000 | 35 ₹3,50,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE Khumbathang
Khumbathang
GE/KHU-46A/2025-26 REPAIR/ REPLACEMENT OF STREET LIGHT AT ZONE A AND B IN THE AOR OF E/M UNDER GE KHUMBATHANG
2025_MES_717058_1
GE/KHU-46A/2025-26
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE Khumbathang
As per tender documents
8 documents required · 8 mandatory
₹500
GE khumbathang
₹70,000
7 Oct 2025
27 Jun 2025
24 Jul 2025
27 Jun 2025
23 Jul 2025
10 Jul 2025
Amount
M & L for checking & repairing Street lights/flood lights/tower lights/highmast lights & other connected work as directed in tech area daily and repairing of lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of cable/lights etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all as specified and directed. NOTES :- (i) Rate quoted shall deemed to be included for required minor material like insulation tap/repairing of junction box with lugs etc. (ii) Items like Driver for LED and other items other than mentioned above will be measured and paid separately. (iii) Contractor shall provided labour at site for rectification/repair and as per direction of Engr-in-Charge.
Supply and fix in repair Driver for LED lights of as per existing make for the following capacity :-
Driver for 60/70 Watts LED
Driver for 40/45 Watts LED
Driver for 25/30 Watts LED
Excavation in trenches not exceeding 1.5m in depth deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr-in-Charge. (Surplus soil if any shall not be removed but left over the trench)
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified and directed. Note :- For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other at site complete all as specified and directed by Engr-in-Charge.
S&F in repair Junction box made out of FRP sheet of size 300x200x115mm make SINTEX, ready made type having aluminium bus bar of capacity 100 Amps 4 Nos with necessary connector , MCB 6 Amps and entry of gland and fixing arrangement to fix the box on plinth/wall by providing MS clamp and nut bolt as per product code GSJB-3020 OF MAKE SINTEX or equivalent. Complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 100 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc. complete all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 70 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 35 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed.
M&L for steel tubular swaged pole complete with cast iron/MS iron base plate welded to the bottom of pole finial taper plug bolts, nuts, screws etc as specified type 410 SP-31(9.0 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of silver paint over one coat of red oxide primer to external/exposed surfaces including excavation and earth work in any type of soil, PCC (1:4:8 ) type D-2 for foundation, PCC (1:2:4) type B-1 for pedestal and coping etc complete all as specified and directed.
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to pole complete all as specified and directed. Make :- Havells/Philips/Osram or equivalent others make as specified.
Supply and fixing in repair PVC insulated and PVC sheathed three core Copper conductor of size 1.5 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacment GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , Clamps (02 sets) of suitable size complete all as specified and directed by Engr-in-Charge.
M&L for Circuit breaker single pole & neutral 240 volt C curve 10 KA 32/40 Amps capacity IP 20 complete all as specified and directed incl taking down old one.
Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 4 core complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 10 Sq mm 4 core complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 2 core complete all as specified and directed by Engr-in-Charge.
M & L for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor,along the pole including taking down complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed by Engr-in-Charge.
Deduct Credit for Demolished/Dismantled material Rs (-) 1,07,645.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S ZAKIR HUSSAIN (BID ID -3368654)
M/S MOHD HUSSAIN (BID ID -3368650)
M/S M A ENTERPRISES (BID ID -3368881)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .