GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair/Replacement of LT electric supply network and misc works at Upper Garrison at YOL CANTT
2023_MES_621935_1
GE/Y-58/2023-24
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (KH) YOL
₹16,000
Yes
20 Dec 2023
6 Oct 2023
10 Nov 2023
6 Oct 2023
3 Nov 2023
20 Oct 2023
Amount
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 185 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified. Note for Srl item Nos. 02 to 07:- (i) Excavation and earth work, sand cushioning, brick work, pipe, cable cover shall be measured and paid separately. (ii) All XLPE cable connected to any LT panel/bus bar should be proper size of cable gland and thimble including quoted rates.
Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50m and depositing where directed at a level n.exc 1.5m high from the starting point, all as specified.
Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Laying only retrived bricks as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Mild steel galvanised light grade 80mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Supply, installation connecting electrically and commissioning switch air break, gang operated, tripple pole mounted on polymer insulator 15 Nos and steel frame with operating mechanism with 20mm dia medium grade GI pipe Rod worked from ground level, drop out fuse, for current rating 200 amps capacity including taking down unservicable air break gang operated switch complete, all as specified and directed.
Cable route indicator made out of 2mm thick mild steel of size 20cmx15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of HT/LT cable in white paint and welded to equal angle of size 30mmX30mmX3mm, 45cm long and errected in ground in such a way that it is 15cm above ground level and 30Cm below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate of size 15cmx20cmx45xcm complete all as specified.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 250 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with fixed thermal and fixed magnectic release, 160 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with fixed thermal and fixed magnectic release, 100 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
Stay assembly complete with MS stay Plate 300X300X6mm thick galvanised stay rod 20mm dia 2.15m long with galvanised bow, galvanised thimble, stay clamp etc. complete all as shown on electrical Plate No.01 of SSR Part-I, including taking down unservicable stay complete, all as specified and directed. Note (excavation, earthwork, PCC work, loop type insulators and stay wire shall be measured and paid separatly.)
Galvanised stay strand strand, 7/4mm dia, complete all as specified.
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5mm, including taking down existing unserviceable complete all as specified.
Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded crushed stone aggregate as in foundation of poles, stays etc. as mass concrete, complete all as specified.
M&L road cutting for laying of cable or under the road or hardstanding by manual for road crossing for using GI tubing of any size for cable protection, complete all as specified and directed by Engr-In-Charge.
Replacement of earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.50m below ground level, earth plate surrounded by 15cm thick packed layer of charcoal and common salt alternatively upto 90cm and connected with and including GI strip of size 25x4mm earthing dia by means of bolts, nuts, check nuts and washers of GI pipe 40mm bore medium grade for protection of GI wire from earth plate to testing point for protection, 20mm bore GI pipe medium grade for water with wire mesh and funnel for watering including necessary excavation and earh work, PCC chamber 1:3:6 type C-2 with RCC cover complete all as shown in electrical plate No. 03 of MES Schedule Part-I, complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC 1:2:4 type B-1, 80mm thick reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrodes shall be protected upto test point using necessary arrangement with suitable size GI pipe upto 7.50m and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and rate includes in the unit rate of item. (iv) The earth chamber shall be condtructed 5m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate quoted for this item.
smc engineering company
Dhani Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .