Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.2 LAccepted-AOC | 1 | Accepted-AOC Lowest and eligible bidder | |
| 2 | 2₹15.2 L+₹3.0 L (24.9%)Rejected-Finance | 2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Feb 2020, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
PETTY ELECTRICAL REPAIR INCLUDING ATTENDING DAY TO DAY COMPLAINTS FOR INTERNAL ELECTRIFICATION UNDER AGE E/M AT MILITARY STATION KOTA
2020_MES_320853_1
8421/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Kota
Class E category a (i) and/or b(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹40,000
Yes
14 May 2020
1 Feb 2020
22 Feb 2020
1 Feb 2020
20 Feb 2020
15 Feb 2020
3 Feb 2020 - 8 Feb 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (excluding fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc) removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, ceiling, etc complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including making good disturbed surface all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
One 3 pin 5 Amp socket outlet point on the same board with other switches.
One 3 pin 5 amps socket outlet point on independent board.
One light point controlled by two, 2-way switches of 5/6 amps.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surface, complete all as directed and specified.
S&F in replacement retrofit 18 watt LED Tube light suitable for fixing to batten type light fitting, complete all as specified and directed. (Make - Havells/Crompton/Syska/HPL/Bajaj)
S&F in replacement batten type LED light fitting (Excluding LED tube) with bipin holders suitable for 18/20 watt retrofit LED tube, powder coated steel, internally prewired, complete all as specified and directed. (Make - Havells/Crompton/Syska/HPL/Bajaj)
S&F in replacement switch piano flush type 5/6 Amps, 230 volts, single pole, one way, complete all as specified and directed. (Make - Anchor, Cona, Havells).
S&F in replacement switch piano flush type 5/6 Amps, 230 volts, single pole, 2 way, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement switch piano flush type 15/16 Amps, 230 volts, single pole, one way, complete all as specified and directed. (Make - Anchor, Cona, Havells).
S&F in replacement socket outlet, 5/6 and 15/16 Amps, 230 volts, multi pin, flush type, universal, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement socket outlet, 5/6 Amps, 230 volts, multi pin, flush type, universal, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement switch socket combination, 5/6 Amps, 230 volt, multi pin, flush type, universal, complete all as specified and directed. (Make - Anchor, Cona Havells)
S&F in replacement switch socket combination, 5 and 15 Amps, 230 volts, multi pin, flush type, universal, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement Lamp Holder (ISI Marked) PVC/Polycarbonate body with back plate, suitable for batten fittings, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement Ceiling rose, surface bakelite, 65x20 mm, three terminal, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacment PLS Lamp two pin 9W, complete all as specified and directed. Make :Crompton/Philips/Wipro
S&F in replacment PLS Lamp two pin 11W, complete all as specified and directed. Make :Crompton/Philips/Wipro
S&F in replacment PLS Lamp two pin 13W, complete all as specified and directed. Make :Crompton/Philips/Wipro
S&F in replacment PLS Lamp two pin 18W, complete all as specified and directed. Make :Crompton /Philips/Wipro
S&F in replacement Recessed mounting LED 2'x2' luminaire, complete all as specified and directed. BCTBLR 36W ZTN NW in make Bajaj or equivelent in Crompton/Syska/HPL/Havells
S&F in replacement Call bell AC 230 Volts, single pole, ding dong sound, complete all as specified and directed. (Make-Anchor, Cona, Havells)
S&F in replacement bell push piano, flush type 5/6 Amps, 230 volts AC,single pole, complete all as specified and directed. (Make - Anchor, Cona, Havells)
S&F in replacement MCB SP 240 Volts, 'B' curve, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed. Make: Legrand/L&T/Siemens.
S&F in replacement MCB SPN 240 Volts, 'B' curve, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed. Make: Legrand/L&T/Siemens.
S&F in replacement MCB TPN 440 Volts, 'C' curve, breaking capacity 10 KA of rating 63 Amps, complete all as specified and directed. Make: Legrand/L&T/Siemens.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 10 Sqmm & earth continuity conductor of size 10 Sqmm, to be drawn through and including PVC casing and caping 25mm width on surface of walls/roof/floors, complete all as specified and directed.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 6 Sqmm & earth continuity conductor of size 6 Sqmm, to be drawn through and including PVC casing and caping 25mm width on surface of walls/roof/floors, complete all as specified and directed.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 4 Sqmm & earth continuity conductor of size 4 Sqmm, to be drawn through and including PVC casing and caping 25mm width on surface of walls/roof/floors, complete all as specified and directed. Note for item Nos 26.00 to 28.00: - Two run of sub main wire, one run of earth wire and one run of PVC casing capping shall be measured as one unit.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 10 Sqmm & earth continuity conductor of size 10 Sqmm, to be drawn through and including existing PVC conduit, complete all as specified and directed.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 6 Sqmm & earth continuity conductor of size 6 Sqmm, to be drawn through and including existing PVC conduit, complete all as specified and directed.
M&L for Sub main wiring power/circuit using FRLS PVC insulated (FRLS) unsheathed, stranded copper conductor cable, 2 Single core of size 4 Sqmm & earth continuity conductor of size 4 Sqmm, to be drawn through and including existing PVC conduit, complete all as specified and directed. Note for item Nos 29.00 to 31.00: - Two run of sub main wire and one run of earth wire shall be measured as one unit.
S&F in replacement sheet metal enclosure for distribution boards, double door, suitable for fixing MCB's, SPN 08 ways, 240 Volts, protection class IP-43, made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface, conforming to IS 13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity, complete all as specified and directed. Make: Legrand/L&T/Siemens.
S&F in replacement sheet metal enclosure for distribution boards, double door, suitable for fixing MCB's, SPN 04 ways, 240 Volts, protection class IP-43, made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface, conforming to IS 13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity, complete all as specified and directed. Make: Legrand/L&T/Siemens.
S&F in replacement sheet metal enclosure for distribution boards, double door, suitable for fixing MCB's, TPN 04 ways, 415 Volts, protection class IP-43, made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface, conforming to IS 13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity, complete all as specified and directed. Make: Legrand/L&T/Siemens. Notes for item Nos 32.00 to 34.00 - (1) The unit rate includes for cutting the brick walls to accommodate enclosure flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity, complete all as specified and directed. Cat Part No 607841 in Make Legrand or equivalent in Seimens/L&T
Dismantling and taking out faulty wiring including casing and capings/conduits etc and refixing the same after rectification of fault in original position including replacment of copper/aluminum cable any size not more than 10 mtr casing/capping/conduit not more than 5 mtr and testing after completion, complete all as specified and directed.
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
All as per item 37.00 above but of size 175x100 mm and 50 mm deep, complete all as specified and directed.
All as per item 37.00 above but of size 200x150 mm and 50 mm deep, complete all as specified and directed.
All as per item 37.00 above but of size 250x200 mm and 50 mm deep, complete all as specified and directed.
S&F in replacement wooden rectangular block for mounting switches, sockets, fan regulators etc with hylam sheets cover of size 250x200mm, complete all as specified and directed.
S&F in replacement wooden rectangular block for mounting switches, sockets, fan regulators etc with hylam sheets cover of size 200x150mm, complete all as specified and directed.
S&F in replacement wooden rectangular block for mounting switches, sockets, fan regulators etc with hylam sheets cover of size 150x100mm, complete all as specified and directed.
M/s Prem Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .