Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹17.2 L+₹70,398 (4.26%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹19.5 L+₹3.0 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Due to L3 | |
| 4 | L4₹19.7 L+₹3.2 L (19.3%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L4 | Rejected-Finance Due to L4 |
Tender Value
Refer Docs
EMD Value
₹39,900
Closing Date
17 Nov 2020, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAINTENANCE AND REPAIR TO WATER SUPPLY LINES AND CONNECTED WORKS AT DOMESTIC AREA AT AFS BIDAR.
2020_MES_387932_1
8246/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹39,900
Yes
27 Nov 2020
19 Oct 2020
18 Nov 2020
19 Oct 2020
17 Nov 2020
3 Nov 2020
Amount
Taking up cast iron water mains 100mm dia/bore (including all fittings), with spigot and socket ends & lead joints including burning out joints and recovering lead complete all as specified and as directed Note : Excavation removal and RFR will be measured and paid separately under respective item.
All as per Item No 01 here in before but 150mm dia
Relaying the serviceable CI Pipe line 100mm dia/bore in the existing trenches/wall with Socket ends complete all as specified and as directed
All as per Item No 03 here in before but 150mm dia
Supply, laying, test and commissioning of Cast iron pipes 100mm dia/bore with spigot and socket ends centrifugally cast, Class LA, bearing ISI mark, in any length, laid in trenches complete all as specified and directed
All as per Item No 05 here in before but 150mm dia
Taking up Ductile iron water mains 100mm dia/bore (including all fittings), with spigot and socket ends and joints including disconnecting pipes and fittings complete. Note : Excavation removal and RFR will be measured and paid separately under respective item.
All as per Item No 07 here in before but 150mm dia
Relaying the serviceable DI Pipe line 100mm dia/ bore in the existing trenches/wall spigot and socket ends including jointing materials complete all as specified and as directed
All as per Item No 09 here in before but 150mm dia
Supply, fix, test and commissioning of Ductile iron pipes 100mm dia/bore with spigot and socket ends, centrifugally cast, class K-7, bearing ISI mark, in any length including jointing materials laid in trenches complete all as specified and directed Note : Excavation removal and RFR will be measured and paid separately under respective item.
All as per Item No 11 here in before but 150mm dia
Taking up or down steel tubing 15mm dia/bore with fittings complete and all as specified and as directed Note : Excavation removal and RFR will be measured and paid separately under respective item.
All as per Item No 13 here in before but 20mm dia
All as per Item No 13 here in before but 25mm dia
All as per Item No 13 here in before but 50mm dia
All as per Item No 13 here in before but 80mm dia
All as per Item No 13 here in before but 100mm dia
Relaying the serviceable GI Pipe line 15mm dia/ bore in the existing trenches/ surface complete all as specified and as directed
All as per Item No 19 here in before but 20mm dia
All as per Item No 19 here in before but 25mm dia
All as per Item No 19 here in before but 50mm dia
All as per Item No 19 here in before but 80mm dia
All as per Item No 19 here in before but 100mm dia
Supply and laying GI Steel tubing medium grade 15mm dia/ bore along with fittings in trenches/ wall complete all as specified and directed
All as per Item No 25 here in before but 20mm dia
All as per Item No 25 here in before but 25mm dia
All as per Item No 25 here in before but 50mm dia
All as per Item No 25 here in before but 80mm dia
All as per Item No 25 here in before but 100mm dia
Disconnection and removing the U/S gate valve 15mm dia/bore and S & F Gun metal globe or gate valve 15mm dia/bore with iron wheel head, screwed both ends for GI Pipe complete all as specified and directed.
All as per Item No 31 here in before but 20mm dia
All as per Item No 31 here in before but 25mm dia
All as per Item No 31 here in before but 50mm dia
Disconnection and removing the unserviceable Air Release valve 50mm dia/bore and S & F Air Release valve double chamber of size 50mm dia/bore with all fittings, including jointing material complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out/for laying under ground pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cms in soil complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M & L for run lead joint, cofirming to IS, 100mm dia /bore CI pipe in position etc., suitable for Spigot and socket pipe & fittings.
All as per Item No 39 here in before but 150mm dia
Disconnection and removing the unserviceable Sluice Valve 80mm dia/bore and S & F Sluice Valve 80mm dia/bore PN 1.6, Non raising type, brass spindle with hand wheel head, screwed both ends for GI Pipe 80 mm dia/bore, including jointing material, complete all as specified and directed.
All as per Item No 41 here in before but 100mm dia
All as per Item No 41 here in before but 150mm dia
Disconnection and removing the unserviceable/ broken Spindle Brass along with the check nuts & gate from the Sluice valve 80mm dia and M&L for New Spindle with Brass Check nuts including polishing, machining, threading & necessary lathe work complete all as specified and as directed
All as per Item No 44 here in before but 100mm dia
All as per Item No 44 here in before but 150mm dia
S & F CI specials such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as spfd and as directed.
S & F DI specials such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as spfd and as directed.
Dismantling the existing u/s valve chamber alongwith unserviceable rusted MS sheet cover and M & L for pit masonary for valves constructed with inner dimensions of 1100 x 1100 x 900 mm suitable for sluice valves upto 150mm with PCC 1:4:8 type D2 for foundation laterite stone masonary wall in cm 1:6 and dressed to prper size, PCC 1:2:4 type B1 for coping rendering in CM 1:4, 15mm thick both side incl provision of MS sheet cover fabricated out of 3mm thick sheet with angle iron frame made out of 40mm x 40mm x 6mm and locking arrangement incl painting with two coats of synthetic enamel paint over a coat of red oxide primer, excavation and earth work complete all as specified and directed as required.
BHIMRAO PATIL
Mr Madhusudhan Kotarki
om sai enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .