Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC 1ST FLOOR FLAT NO 101 NAVRACHNA PARADISE COLONEL ENCLAVE DELHI ROAD ROORKEE HARIDWAR UK 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹11.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹12.6 L+₹64,500 (5.40%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | ₹12.6 L+₹64,500 (5.40%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹12.7 L+₹77,000 (6.44%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | ₹12.7 L+₹77,000 (6.44%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹13.7 L+₹1.8 L (15.0%)Rejected-Finance | ₹13.7 L+₹1.8 L (15.0%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹23.6 L+₹11.6 L (97.2%)Rejected-Finance | ₹23.6 L+₹11.6 L (97.2%) | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/S A.K GARG L4 | VIJAY ENTERPRISES L2 | OMVIN ENTERPRISES LLP L3 | Niyana Innovation Works L1 | M/s Chittar Mal & Co. L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting existing Cables and earthing strip from unserviceable panel. Dismantling and taking out the panel and making good the disturbed surface of the same location for fixing a new panel all as directed by Engr in charge. | 3 | Each | 200 ₹600 Lowest | 1,000 ₹3,000 | 500 ₹1,500 | 1,000 ₹3,000 | 2,000 ₹6,000 |
| 2.00 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board ( KIOSK TYPE ) Double door CPRI approved factory assembled made out door feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium Bus bars for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT's -03 Set, Phase indicator lamps with holder , toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm and frame structure of panel will be made angle iron of size 50 x 50 x 6 mm. complete all as specified and directed. ( Feeder piller box shall be consisting the following)
(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of Rating 1000 Amps with provision of extension and mounting on porcelain insulators.
(b) ACB 630 amp FP, 415 volts, with Thermal Magnetic Release (Manual Drawout type), 50Hz = 01 No (Incoming)
(c) MCCB TP 200 amps, 36 KA , 415 volts, 50Hz - 02 Nos (Outgoing)
(d) MCCB TP 160 amps, 25 KA , 415 volts, 50Hz - 02 Nos, (Outgoing)
(e) MCCB TP 125 amps, 16 KA , 415 volts, 50Hz - 02 Nos, (Outgoing)
(f) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set
(g) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos.
(h) RYB indicating lamp, LED type - 01 sets.
(i) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.
(j) Drawing shall be approved by GE before placing the order. | 1 | Each Job | 3,60,500 ₹3,60,500 | 3,50,000 ₹3,50,000 | 3,50,000 ₹3,50,000 | 3,18,000 ₹3,18,000 Lowest | 3,80,000 ₹3,80,000 |
| 3.00 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board ( KIOSK TYPE ) Double door, CPRI approved factory assembled made out door feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium Bus bars for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT's -03 Set, Phase indicator lamps with holder , toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm and frame structure of panel will be made angle iron of size 50 x 50 x 6 mm. complete all as specified and directed. ( Feeder piller box shall be consisting the following)
(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of Rating 2000 Amps with provision of extension and mounting on porcelain support
(b) ACB 1250 amp FP, 415 volts, with Thermal Magnetic Release (Manual Drawout type), 50Hz = 01 No (Incoming)
(c) MCCB TP 400 amps, 36 KA , 415 volts, 50Hz - 01 Nos (Outgoing)
(d) MCCB TP 250 amps, 25 KA , 415 volts, 50Hz - 02 Nos, (Outgoing)
(e) MCCB TP 200 amps, 25 KA , 415 volts, 50Hz - 01 Nos, (Outgoing)
(f) MCCB TP 160 amps, 25 KA , 415 volts, 50Hz - 01 Nos, (Outgoing)
(g) MCCB TP 125 amps, 16 KA , 415 volts, 50Hz - 01 Nos, (Outgoing)
(h) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set
(i) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos
(j) RYB indicating lamp, LED type - 01 sets.
(k) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.
(l) Drawing shall be approved by GE before placing the order. | 1 | Each Job | 4,06,500 ₹4,06,500 | 4,50,000 ₹4,50,000 | 4,30,000 ₹4,30,000 | 3,45,000 ₹3,45,000 Lowest | 4,50,000 ₹4,50,000 |
| 4.00 | M& L, for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below groud level with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X 6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, with fair finish, inetrnal surface of concrete chamber shall be given internal dia 300mm X 300mm , 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all, as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified incuding and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, Medium grade, including all excavation and earthn work and connecting the earth strip to an earthing test point/panel including testing on completion complete alll as specified and directed. | 12 | Each | 5,000 ₹60,000 | 6,500 ₹78,000 | 4,500 ₹54,000 | 3,500 ₹42,000 Lowest | 11,000 ₹1,32,000 |
| 5.00 | Disconnecting existing cables from incomer and outgoing ACB, mccbs of existing panel cleaning the complete surface of the panel , including removal of rust, dirt, loose paint, and moisture using sandpaper , brush or blower. Jointing of broken door with welding and other required accessories i.e Kabja, hing etc. Preparation of LT panel with one coat anti-rust primer and two coats of industrial-grade enamel paint on both sides . cleaning and painting of legs of the panels are included . After painting connections of the cables with mccbs of panels with news thimbles/lugs and suitable size of cable glands with making holes if required and connecting accessories etc. Note: refixing of the panel if required to be included this item. Approx Size of the panel :600mmx300mmx450mm, with following accessories. These accessories will be uninstalled for painting and replacement of store said part. Reinstallation of these parts is included in this item.as directed by Engr in charge.
a) No of Incomming ACB 1250 Amp - 01, Size of cable - 180 sq mm to 400mm x 3.5/4 core b) No of Outgoing MCCBs 250 Amp- 01, Size of cable - 25 sq mm to 240 sq mm x 3.5/4 Core c) No of Outgoing MCCBs 250 Amp-01, Size of cable - 25 sq mm to 240 sq mm x 3.5/4 core d) No of Outgoing MCCBs 200 Amp-01, Size of cable - 25 sq mm to 240 sq mm x 3.5/4 core e) No of Outgoing MCCBs 63 Amp-01, Size of cable - 25 sq mm to 180 sq mm x 3.5/4 core f) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 180 sq mm x 3.5/4 core | 1 | Each Job | 32,000 ₹32,000 | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest | 35,000 ₹35,000 | 4,00,000 ₹4,00,000 |
| 6.00 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board ( KIOSK TYPE ) Double door CPRI approved factory assembled made out door feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium Bus bars for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT's -03 Set, Phase indicator lamps with holder , toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm and frame structure of panel will be made angle iron of size 50 x 50 x 6 mm. complete all as specified and directed. ( Feeder piller box shall be consisting the following)
(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of Rating 1000 Amps with provision of extension and mounting on porcelain insulators.
(b) ACB 630 amps, 415 volts, 50Hz Manual drawout type = 01 No (Incoming)
(c) MCCB TP 200 amps, 36 KA , 415 volts, 50Hz - 02 Nos (Outgoing)
(d) MCCB TP 120 amps, 16 KA , 415 volts, 50Hz - 03 Nos, (Outgoing)
(e) MCCB TP 63 amps, 16 KA , 415 volts, 50Hz - 03 Nos, (Outgoing)
(f) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set
(g) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos
(h) RYB indicating lamp, LED type - 01 sets.
(i) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.
(j) Drawing shall be approved by GE before placing the order. | 1 | Each Job | 4,24,000 ₹4,24,000 | 3,25,000 ₹3,25,000 Lowest | 3,70,000 ₹3,70,000 | 3,39,000 ₹3,39,000 | 4,00,000 ₹4,00,000 |
| 7.00 | Disconnecting existing cables from incomer and outgoing ACB, mccbs of existing panel cleaning the complete surface of the panel , including removal of rust, dirt, loose paint, and moisture using sandpaper , brush or blower. Jointing of broken door with welding and other required accessories i.e Kabja, hing etc. Preparation of LT panel with one coat anti-rust primer and two coats of industrial-grade enamel paint on both sides . cleaning and painting of legs of the panels are included . After painting connections of the cables with mccbs of panels with news thimbles/lugs and suitable size of cable glands with making holes if required and connecting accessories etc. Note: refixing of the panel if required to be included this item. Approx Size of the panel :600mmx300mmx450mm, with following accessories. These accessories will be uninstalled for painting and replacement of store said part. Reinstallation of these parts is included in this item.as directed by Engr in charge. a) No of Incomming ACB 1250 Amp - 01, Size of cable - 180 sq mm to 400 sq mm x 3.4/4 core lead b) No of Outgoing MCCBs 200 Amp- 01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
c) No of Outgoing MCCBs 125 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
d) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
e) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
f) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
g) No of Outgoing MCCBs 100 Amp-01, Size of cable -25 sq mm to 150 sq mm x 3.5/4 Core | 1 | Each Job | 35,000 ₹35,000 | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest | 35,000 ₹35,000 | 4,00,000 ₹4,00,000 |
| 8.00 | Disconnecting existing cables from incomer and outgoing ACB, mccbs of existing panel cleaning the complete surface of the panel , including removal of rust, dirt, loose paint, and moisture using sandpaper , brush or blower. Jointing of broken door with welding and other required accessories i.e Kabja, hing etc. Preparation of LT panel with one coat anti-rust primer and two coats of industrial-grade enamel paint on both sides . cleaning and painting of legs of the panels are included . After painting connections of the cables with mccbs of panels with news thimbles/lugs and suitable size of cable glands with making holes if required and connecting accessories etc. Note: refixing of the panel if required to be included this item. Approx Size of the panel :600mmx300mmx450mm. These accessories will be uninstalled for painting and replacement of store said part. Reinstallation of these parts is included in this item.as directed by Engr in charge.
a) No of Incomming MCCBs 250 Amp - 01, Size of cable -25 sq mm to 150 sq mm x 3.5/4 Core b) No of Outgoing MCCBs 200 Amp- 01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
c) No of Outgoing MCCBs 200 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
d) No of Outgoing MCCBs 100 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core e) No of Outgoing MCCBs 100 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core f) No of Outgoing MCCBs 100 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core | 1 | Each Job | 39,500 ₹39,500 | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest | 28,000 ₹28,000 | 1,60,000 ₹1,60,000 |
| 9.00 | Disconnecting carefully old unsericeable Ammeter from panel board and supply & fix of new 96 mm size square digital type ammeter of range 0-100 Ampere with set of CTs of suitable rating Supply and laying or fixing. complete all as specified & directed. | 5 | Each | 800 ₹4,000 Lowest | 1,100 ₹5,500 | 1,300 ₹6,500 | 4,000 ₹20,000 | 5,000 ₹25,000 |
| 10.00 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified & directed. | 6 | Each | 2,100 ₹12,600 | 3,000 ₹18,000 | 5,000 ₹30,000 | 5,000 ₹30,000 | 501 ₹3,006 Lowest |
Tender Value
₹14.5 L
EMD Value
₹29,040
Closing Date
11 Feb 2026, 6:00 pmClosed
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
REPAIR/REPLACEMENT OF LT PANELS WITH CONNECTING ITEMS IN MH ROORKEE, GR LINE UNDER GE (MES) ROORKEE
2026_MES_750194_1
95464/RKE/E8
Open Tender
Civil Works
Item Rate
90 days
Roorkee
Please refer tender pages
9 documents required · 9 mandatory
₹500
GE Roorkee
₹29,040
17 Mar 2026
28 Jan 2026
13 Feb 2026
28 Jan 2026
11 Feb 2026
4 Feb 2026
Disconnecting existing Cables and earthing strip from unserviceable panel. Dismantling and taking out the panel and making good the disturbed surface of the same location for fixing a new panel all as directed by Engr in charge.
M& L, for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below groud level with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X 6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, with fair finish, inetrnal surface of concrete chamber shall be given internal dia 300mm X 300mm , 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all, as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified incuding and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, Medium grade, including all excavation and earthn work and connecting the earth strip to an earthing test point/panel including testing on completion complete alll as specified and directed.
Disconnecting existing cables from incomer and outgoing ACB, mccbs of existing panel cleaning the complete surface of the panel , including removal of rust, dirt, loose paint, and moisture using sandpaper , brush or blower. Jointing of broken door with welding and other required accessories i.e Kabja, hing etc. Preparation of LT panel with one coat anti-rust primer and two coats of industrial-grade enamel paint on both sides . cleaning and painting of legs of the panels are included . After painting connections of the cables with mccbs of panels with news thimbles/lugs and suitable size of cable glands with making holes if required and connecting accessories etc. Note: refixing of the panel if required to be included this item. Approx Size of the panel :600mmx300mmx450mm, with following accessories. These accessories will be uninstalled for painting and replacement of store said part. Reinstallation of these parts is included in this item.as directed by Engr in charge. a) No of Incomming ACB 1250 Amp - 01, Size of cable - 180 sq mm to 400mm x 3.5/4 core b) No of Outgoing MCCBs 250 Amp- 01, Size of cable - 25 sq mm to 240 sq mm x 3.5/4 Core c) No of Outgoing MCCBs 250 Amp-01, Size of cable - 25 sq mm to 240 sq mm x 3.5/4 core d) No of Outgoing MCCBs 200 Amp-01, Size of cable - 25 sq mm to 240 sq mm x 3.5/4 core e) No of Outgoing MCCBs 63 Amp-01, Size of cable - 25 sq mm to 180 sq mm x 3.5/4 core f) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 180 sq mm x 3.5/4 core
Disconnecting existing cables from incomer and outgoing ACB, mccbs of existing panel cleaning the complete surface of the panel , including removal of rust, dirt, loose paint, and moisture using sandpaper , brush or blower. Jointing of broken door with welding and other required accessories i.e Kabja, hing etc. Preparation of LT panel with one coat anti-rust primer and two coats of industrial-grade enamel paint on both sides . cleaning and painting of legs of the panels are included . After painting connections of the cables with mccbs of panels with news thimbles/lugs and suitable size of cable glands with making holes if required and connecting accessories etc. Note: refixing of the panel if required to be included this item. Approx Size of the panel :600mmx300mmx450mm, with following accessories. These accessories will be uninstalled for painting and replacement of store said part. Reinstallation of these parts is included in this item.as directed by Engr in charge. a) No of Incomming ACB 1250 Amp - 01, Size of cable - 180 sq mm to 400 sq mm x 3.4/4 core lead b) No of Outgoing MCCBs 200 Amp- 01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core c) No of Outgoing MCCBs 125 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core d) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core e) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core f) No of Outgoing MCCBs 160 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core g) No of Outgoing MCCBs 100 Amp-01, Size of cable -25 sq mm to 150 sq mm x 3.5/4 Core
Disconnecting existing cables from incomer and outgoing ACB, mccbs of existing panel cleaning the complete surface of the panel , including removal of rust, dirt, loose paint, and moisture using sandpaper , brush or blower. Jointing of broken door with welding and other required accessories i.e Kabja, hing etc. Preparation of LT panel with one coat anti-rust primer and two coats of industrial-grade enamel paint on both sides . cleaning and painting of legs of the panels are included . After painting connections of the cables with mccbs of panels with news thimbles/lugs and suitable size of cable glands with making holes if required and connecting accessories etc. Note: refixing of the panel if required to be included this item. Approx Size of the panel :600mmx300mmx450mm. These accessories will be uninstalled for painting and replacement of store said part. Reinstallation of these parts is included in this item.as directed by Engr in charge. a) No of Incomming MCCBs 250 Amp - 01, Size of cable -25 sq mm to 150 sq mm x 3.5/4 Core b) No of Outgoing MCCBs 200 Amp- 01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core c) No of Outgoing MCCBs 200 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core d) No of Outgoing MCCBs 100 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core e) No of Outgoing MCCBs 100 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core f) No of Outgoing MCCBs 100 Amp-01, Size of cable - 25 sq mm to 150 sq mm x 3.5/4 Core
Disconnecting carefully old unsericeable Ammeter from panel board and supply & fix of new 96 mm size square digital type ammeter of range 0-100 Ampere with set of CTs of suitable rating Supply and laying or fixing. complete all as specified & directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified & directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tender95464.pdf
Tender Documents • 1.69 MB
BOQ_840213.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .