Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAccepted-AOC 59 8E CROSS ROAD ATTIGUPPE WEAVERS COLONY NEAR GOVT PU COLLEGE VIJAY NAGAR BANGALORE 560 040 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560040 | L1 | Accepted-AOC Qualified and rates are found reasonable |
Tender Value
₹42.7 L
EMD Value
₹50,000
Closing Date
13 Sept 2021, 4:00 pmClosed
Regional Engineer
Kerala State Nirmithi Kendra NHEC Barton hill Vanchiyoor P O Thiruvananthapuram
Supplying Erection Testing and Commissioning Medical gas pipeline Other Equipments and Operation Theatre Light.
2021_KSNK_437601_1
KSNK/TECH/NHEC/SLP-202R1/2021
Open Tender
Civil Works - Others
Item Rate
30 days
Parippally
REFER NIT
6 documents required · 6 mandatory
₹2,500
₹50,000
Yes
16 Oct 2021
3 Sept 2021
15 Sept 2021
3 Sept 2021
13 Sept 2021
3 Sept 2021
3 Sept 2021 - 13 Sept 2021
Amount
Supplying and fixing LED Clean Room Top Openable Light Fitting having Ss Bottom Frame / Powder Coated Bottom Frame Top Cover Suitable For Walkeable Ceiling of size 600mm x 600mm
Suppying Celing 600mm x 600mm size Recess mounted IP54 protocol, non-hygroscopic peripheral lights for clean room application each set having LED Lights with dimmer control (Suitable for Clean room Class 100 application)
Supplying operation theater table and accessories should have a minimum of 4 sections, table should have an easily detachable split leg and an easily detachable head section, tabletop should have a minimum height of 780mm or lesser, tabletop should have a minimum vertical stroke of 250mm, Should have a sealed hydraulic mechanism to avoid oil spillag, Should have at least 25 degrees Trendelenburg and reverse Trendelenburg, Should have at least 20 degrees lateral tilt movement, . Should have at least 80 degrees back up movement with the gas spring mechanism, head section should have up and down movement, leg section should have 90 degrees down movement and should move sidewards to a minimum of 90 degrees, table should have a heavy and sturdy base and compact to provide adequate foot room for the operating team, table should be mounted on heavy-duty casters which offer enhanced weight bearing capacity and free mobility, table should have a single lever foot-operated brake pedal.Should have minimum patient weight-bearing capacity of 120 Kgs, Base should be made of cast iron and all other parts and accessories should be completely made of Stainless Steel 304 grade except the cushion and gas spring, table should be supplied with the following accessories,Mattress for the complete tabletop in sections - 1 set, A pair of arm boards with pad and fixing clamp - 1, A pair of padded shoulder support with clamps - 1, A pair of padded lateral support with clamps - 1, A pair of leg crutches with clamps - 1, Anesthetic screen frame with clamp -1,Patient restraint strap - 1, The table should have the facility for easily detachable kidney bridge attachment or an inbuilt kidney bridge, KMSCL Running Contract available, should be supply as per running contract specification
Supplying and fixing medical gas wall outlet Front-loading type terminal outlets should be designed to dispense medical gases (or an inlet for medical vacuum) to the secondary equipment (flow meters, Surgical Tools, Suction regulators, etc.) at the point of use and it should be gas specific so that secondary devices cannot be “attached” to the wrong gas, When not in use, the gas should be in a non-flowing state within the Outlet (Terminal unit) sealed by “O” ring. The adapter when inserted pushes the poppet inside and the gas starts flowing and sealing is ensured by the “O” ring or a seat,The outlets should Quick Connect Type and gas specificity is accomplished by "Diametric indexing." / Geometric indexing/ BS/ DIN/ NFPA, Should have Pushed to insert and press-to-release mechanism for probes.
Supplying bed head unit 3 gas point and 4 switch with sockets (1 metre)Minimum length 1/1.2/1.5 metres, It should be made of High Strength Anodised Aluminium Profiles with integrated rail system for mounting accessories,Should be powder-coated (color as per user choice). Should provide backside cover, The panel should be designed to have provisions to accommodate the following, Supplying and fixing following modular switch/ socket on the existing, modular plate & switch box, including connections but excluding modular plate etc. as required (for one-bed head panel), KMSCL Running Contract available, should be supply as per running contract specification
Solid drawn seamless deoxidised ,non-arsencial ,half hard ,tempered and degreased copper pipes -as per specification 28 mm OD XX 0.9 mm thick(KMSCL Running Contract available, should be supply as per running contract specification)
Solid drawn seamless deoxidised ,non-arsencial ,half hard ,tempered and degreased copper pipes -as per specification 22 mm OD XX 0.9 mm thick( KMSCL Running Contract available, should be supply as per running contract specification)
Solid drawn seamless deoxidised ,non-arsencial ,half hard ,tempered and degreased copper pipes -as per specification 15 mm OD XX 0.7 mm thick( KMSCL Running Contract available, should be supply as per running contract specification)
Supplying medical mobile UV disinfection UVC room air steriliser-Should be portable type, needed for room sterlisation
Providing,Fixing,Supply and Installation of storage unit size of (1665mmx865mmx350mm)made of 1.60mm SS 304 steel complete with all accessories etc of Hitek.
Ward vacuum Unit:Supply installation,testing and commissioning of ward suction unit.As per technical specifications.(KMSCL Running Contract available, should be supply as per running contract specification)
Portable vacuum unit for OT.As per Technical specifications.Features, Portable, High Vacuum, Mobile Suction Units, Easy to clean plastic
Supply Installation testing and commissioning of Medical gas hose assemblies hose shall be colour coded throughout their length as specified in British standards
O2 male probe-Din out let probe, (KMSCL Running Contract available, should be supply as per running contract specification)
N2O male probe(KMSCL Running Contract available, should be supply as per running contract specification)
MA 4 bar probe(KMSCL Running Contract available, should be supply as per running contract specification)
Supplying medical gas system with anesthetist pendents plus copper pipe and other valves and monitors.(KMSCL Running Contract available, should be supply as per running contract specification)
LSCS Set-should have good quality metal (stainless steel )with all set of instruments including stainless steel box
Spinal Set-Should have good quality stainless type instruments
Suction Apparatus-Rating of Motor – continuous,Motor – thermally protected,Valves – Stainless steel, Filter – Bacterial filter autoclavable/ reusable, Suction Bottle Capacity - 2 x 2000 ml minimum (with safety valve), Gauge - 0 to 760 mm Hg, Vacuum Maximum - 660 mm Hg. Pump – Oil free Twin headed Piston pump,Suction Tubings - ID 7 mm, 5m long and non-collapsible., Should have air tight lids interconnected with both jars, Should have a noiseless Operation, Should provide filter to absorb moisture and water particles entering into the rotor, Should have a safety valve to prevent entry of fluids into machine in case the suction jar fills up, Should be well-designed, cabinet made of Stainless Steel 304 Grade, Should have facility to adjust suction pressure, Should bear ISI / CE mark, Should operate from 200 to 240Vac, 50 Hz input supplyKMSCL Running Contract available, should be supply as per running contract specification
Diathermy-Electro cautery machine Should have Monopolar & bi-polar cutting facility, Smart generator should be able to monitor changes in tissue impedance continuously and adjusts power, Monopolar outputs should have three cutting modes: a. Low cut for delicate tissue or Laproscopic cases havingmaximum power of 300w, b. Pure cut for clean, precise cut in general surgery having maximum power of 200W, c. Blend mode for cutting with homeostasis having, maximum power of 200W, All cut modes should be able to adjust output power depending, on tissue density by less than 15% or 5W, whichever is greater, It should have three Coag Modes with maximum power of 120W, a. Desiccate mode for low voltage contact coagulation suitable for Laproscopic and delicate tissue work.b. Fulgurate mode for efficient non-contact coagulation in most applications.c. Spray mode should have randomized spray effect ofvarying amplitude and frequency for coagulating large tissue areas with minimum depth of necrosis. It should have three bipolar modes with maximum power of 70W, a. Precise mode have fine control of desiccation indelicate tissue.b. Standard mode for applications at low voltage to prevent sparking.c. Macro mode for applications on tissue with high resistance.The unit should have individual digital display of power forBipolar, Monopolar cut and Monopolar Coag.The unit should not have RF Leakage current more than 150mA, The unit should have two hand switching and two Footswitch, Monopolar outputs and one hand switching and footswitching, bipolar output. It should have patient plate monitoring facility and should giveaudiovisual alarm and deactivate output if contact between, patient and patient plate is not proper to eliminate the risk ofpatient burns. Accessories:-a. Monopolar Footswitch:- 02 No.b. Bipolar Footswitch:- 01 No. c. Reusable hand switching Pencil: - 02 Nos.d. Reusable Patient Plate : - 02nos.e. Bipolar Forceps: - 01No.f. Forceps Cord:- 02Nos. g. Universal Adaptor: - 01No.Two years of comprehensive warranty including bulbs shouldbe provided along with technical support. It should follow international Safety Standard and requirementwith CE Certification or USFDA Approval.Users list with the addresses and contact nos. to be provided.Demonstration Compulsory.Operating and service manual should be supplied.Tropicalization: operating Temp. upto 40Deg. C;
Surgical Drum Large-should have good quality material Surgical Drum with Large size
Surgical Drum Medium-should have good quality material Surgical Drum with medium size
Surgical Drum Small-should have good quality material Surgical Drum with small size
Mayo's Trolley-Stainless Steel type, should have wheel for rotating lid, should have tray mounted at top
Steel Foot Step-Stainless Steel foot step
Roller Shifter Stainless steel
Tray Lid Large-Stainless steel type,
Tray Lid Medium-Stainless steel type,
Tray Lid Small-Stainless steel type,
Small Bowl-
Medium Bowl
Kidney Tray Large Stainless steel type
Kidney Tray Medium Stainless steel type
Instrument setting trolley-Stainless steel type, should have two plat form ( top plat form & Bottom plat form)
Spot Light-Mobile LED spot ligt having good quality light (white colour light preferable)
Crash cart-Overall approx dimensions: 900 L x 400 mm W x 1540 mm H.Complete SS Framework and SS Shelves. Two Polystyrene Lockable Storage units with Three Drawer each.6 Nos. ...Stainless Steel Saline Rod made of 12 mm dia. Mounted on 125 mm Dia non-rusting swivel casters two with brake.
Bain Circuit-
Stretcher trolley with side rail & belt- 1. Size : 2000mm (L) x 660mm (W) x 830mm (H) 2. Main frame : 32mm OD x 1.6 mm Thick M.S E.R.W 3. Supporting frame : 25mm OD x 1.6 mm Thick M.S E.R.W4. Castor wheels with 200 mm dia.5. Diagonal Dual lock castors 6. Stretcher top frame 25mm OD x 1.6 mm Thick M.S E.R.W 7. Sheet should be made of CRCA of 1.2mm thickness 8. Provision for IV pole.9. Max. Load of 1000 Kg,10. Provision for carrying oxygen cylinder. 11. Finish: powder coated with anti-microbial epoxy polyester powder. 12. Should supply with Stainless Steel stretcher and removable mattress (washable)13. Should comply with National / International standards
Table top Electrical sewing machine
Oxygen Cylinder Stardard A type
Oxygen Cylinder Stardard B type
Oxygen Conversion Kit
Nitrous Oxide Clinder
Inverter
Emergency Lamp
Torch
Patient Warmer
Water Purifier
Induction Cooker
Foetal Doppler-Hand held foetal doppler with rechargable type, recharger needed
Glucometer
Bp Apparatus Manual
BP Apparatus Digital
Nebuliser
Office Table
Steel Almirah
Refrigerator-Refrigerator with stabilizer 1. Should have a Capacity of 165 Litres or above. 2. Shelves shall be of Toughened glass type. 3. Should have EEC 4 star rating or above. 4. Should have inbuilt protection for voltage fluctuation or to be supplied with external stabilizer of adequate KVA capacity.
Suppying Celing OT light, LED type, Number of doom -2, Position - celing Mounted, Power Supply Single Phase, 220/110V +/- 10% AC, 50/60 Hz Number of Domes Two Domes with 7 Modules)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .