Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAdmitted-Fee/PreQual/Technical/Finance AT PO TALBANI CITY PASCHIM MEDINIPUR STATE WEST BENGAL PIN 721156 | PASCHIM MEDINIPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721156 | ₹6.1 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹8.1 L+₹2.0 L (32.2%)Admitted-Fee/PreQual/Technical/Finance | ₹8.1 L+₹2.0 L (32.2%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | SHIVASAKTI ENGINEERING AND CONSTRUCTION. L2 | CHITTARANJAN MAITY L1 |
|---|---|---|---|---|---|
| 1.00 | Repairing of Garden Light and column light (Lantern type/ column type) installed at different locations of Basundhara Area by Supplying & Fixing one number of 36W, 3A (IP65) LED Driver & 36 Watt LED PCB Module having Copper Thickness- min. 35 Micron, Shape-Round/rectangular, Luminous Flux (lm)-3360, Emitting Color-Warm White, working Hours- min. 50000, (Board With SMD LEDs) along with connecting wire terminal, SP MCB etc. complet as required. | 151 | Each | 1,200 ₹1,81,200 | 799 ₹1,20,649 Lowest |
| 2.00 | Repairing of Bollard Light installed at different locations of Basundhara Area by Supplying & Fixing of of one number of LED Driver 60W 12V 5A & one number of suitable LED PCB Module, ( Board With SMD LEDs) 60 Watt, along with connecting wire terminal, reflectors etc. complet as required. | 119 | Set | 750 ₹89,250 | 610 ₹72,590 Lowest |
| 3.00 | Supply, installation, testing and commissioning of Surge Protection Device (SPD), Single Phase (1P+N), Type 1+2, conforming to IEC 61643-11, suitable for protection against direct lightning current, indirect lightning surges and switching transients, having minimum ratings as Nominal System Voltage: 230 V AC, 50 Hz, Configuration: 1P+N, SPD Type: Type 1+2, Impulse Current (Iimp): min. 12.5 kA (10/350 µs), Maximum Discharge Current (Imax): 50 kA (8/20 µs), Voltage Protection Level (Up): As per IEC 61643-11, Visual status indication and plug-in replaceable cartridge arrangement, Complete with one (01) additional spare set of 1P+N replaceable cartridge for each SPD supplied. The complete SPD assembly shall be housed inside a weatherproof Light Junction Box of minimum size 400 mm × 300 mm × 200 mm, having Polycarbonate/FRP enclosure with transparent hinged lid IP65/IP67 protection, UV resistant, flame-retardant and corrosion-resistant, Factory premoulded cable entry or suitable cable gland arrangement, Suitable DIN rail, mounting plate and accessories for mounting the SPD including connecting cupper wires and all accessories as required for complete. | 4 | Each | 16,500 ₹66,000 | 11,999 ₹47,996 Lowest |
| 4.00 | Supply, installation, testing and commissioning of Surge Protection Device (SPD), Three Phase (3P+N), Type 1+2, conforming to IEC 61643-11, suitable for protection against direct lightning current, indirect lightning surges and switching transients, having minimum ratings as Nominal System Voltage: 415 V AC, 50 Hz, Configuration: 3P+N, SPD Type: Type 1+2, Impulse Current (Iimp): min. 12.5 kA (10/350 µs), Maximum Discharge Current (Imax): 50 kA (8/20 µs), Voltage Protection Level (Up): As per IEC 61643-11, Visual status indication and plug-in replaceable cartridge arrangement, Complete with one (01) additional spare set of 3P+N replaceable cartridge for each SPD supplied. The complete SPD assembly shall be housed inside a weatherproof Light Junction Box of minimum size 400 mm × 300 mm × 200 mm, having Polycarbonate/FRP enclosure with transparent hinged lid IP65/IP67 protection, UV resistant, flame-retardant and corrosion-resistant, Factory premoulded cable entry or suitable cable gland arrangement, Suitable DIN rail, mounting plate and accessories for mounting the SPD including connecting cupper wires and all accessories as required for complete. | 3 | Each | 19,000 ₹57,000 | 13,999 ₹41,997 Lowest |
| 5.00 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole | 30 | Each | 200 ₹6,000 Lowest | 201 ₹6,030 |
| 6.00 | Supply & Fixing of 12 Watt spot or Spike light for (LED light) outdoor IP65, Colour: Red/Green/Warm White. Input Voltage : (85-265V), Diameter; 60mm to be fitted in different locations of Basundhara Area. | 50 | Each | 650 ₹32,500 | 525 ₹26,250 Lowest |
| 7.00 | Supply & Fixing of one number of 25 Amp 300 Watt 12V RGB SMPS Driver. Input Voltage :180-265V AC, Out Put: 12V, 25A outdoor type IP65 and one number of 24A, 12 V, LED RGB Controller in the existing control panel. | 12 | Set | 2,200 ₹26,400 | 2,020 ₹24,240 Lowest |
| 8.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 80 | Mtr | 210 ₹16,800 | 172 ₹13,760 Lowest |
| 9.00 | Laying of one number additional PVC insulated and PVC sheathed XLPE power cable of 1.1KV grade of following sizedirect in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering Above 35 sq. mm and upto 95 sq. mm | 300 | Mtr | 88 ₹26,400 | 63 ₹18,900 Lowest |
| 10.00 | Supply, laying and fixing of 3Cx2.5 Sq mm industrial flexible (FRLS) insulated cupper power cable of 1.1KV grade of following size on wall surface as required. | 250 | Mtr | 210 ₹52,500 | 184 ₹46,000 Lowest |
Tender Value
₹9.1 L
EMD Value
₹11,400
Closing Date
11 Aug 2026, 5:00 pmClosed
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Repairing of outdoor Decorative Lights at Community Places, Open gym, Children park, Meghdoot, Guest House, office in Township Basundhara Area
2026_MCL_362568_1
MCL/GM/ BA/EM/e-Proc/2026-27/ 04 Date- 25/07/2026
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
BASUNDHARA AREA
AS PER NIT AND TC
4 documents required · 4 mandatory
₹11,400
17 Aug 2026
27 Jul 2026
14 Aug 2026
27 Jul 2026
11 Aug 2026
28 Jul 2026
27 Jul 2026 - 31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing of Garden Light and column light (Lantern type/ column type) installed at different locations of Basundhara Area by Supplying & Fixing one number of 36W, 3A (IP65) LED Driver & 36 Watt LED PCB Module having Copper Thickness- min. 35 Micron, Shape-Round/rectangular, Luminous Flux (lm)-3360, Emitting Color-Warm White, working Hours- min. 50000, (Board With SMD LEDs) along with connecting wire terminal, SP MCB etc. complet as required. | - | Each | 1,378.95 | - |
| 2 | Repairing of Bollard Light installed at different locations of Basundhara Area by Supplying & Fixing of of one number of LED Driver 60W 12V 5A & one number of suitable LED PCB Module, ( Board With SMD LEDs) 60 Watt, along with connecting wire terminal, reflectors etc. complet as required. | - | Set | 763.67 | - |
| 3 | Supply, installation, testing and commissioning of Surge Protection Device (SPD), Single Phase (1P+N), Type 1+2, conforming to IEC 61643-11, suitable for protection against direct lightning current, indirect lightning surges and switching transients, having minimum ratings as Nominal System Voltage: 230 V AC, 50 Hz, Configuration: 1P+N, SPD Type: Type 1+2, Impulse Current (Iimp): min. 12.5 kA (10/350 µs), Maximum Discharge Current (Imax): 50 kA (8/20 µs), Voltage Protection Level (Up): As per IEC 61643-11, Visual status indication and plug-in replaceable cartridge arrangement, Complete with one (01) additional spare set of 1P+N replaceable cartridge for each SPD supplied. The complete SPD assembly shall be housed inside a weatherproof Light Junction Box of minimum size 400 mm × 300 mm × 200 mm, having Polycarbonate/FRP enclosure with transparent hinged lid IP65/IP67 protection, UV resistant, flame-retardant and corrosion-resistant, Factory premoulded cable entry or suitable cable gland arrangement, Suitable DIN rail, mounting plate and accessories for mounting the SPD including connecting cupper wires and all accessories as required for complete. | - | Each | 17,010.95 | - |
| 4 | Supply, installation, testing and commissioning of Surge Protection Device (SPD), Three Phase (3P+N), Type 1+2, conforming to IEC 61643-11, suitable for protection against direct lightning current, indirect lightning surges and switching transients, having minimum ratings as Nominal System Voltage: 415 V AC, 50 Hz, Configuration: 3P+N, SPD Type: Type 1+2, Impulse Current (Iimp): min. 12.5 kA (10/350 µs), Maximum Discharge Current (Imax): 50 kA (8/20 µs), Voltage Protection Level (Up): As per IEC 61643-11, Visual status indication and plug-in replaceable cartridge arrangement, Complete with one (01) additional spare set of 3P+N replaceable cartridge for each SPD supplied. The complete SPD assembly shall be housed inside a weatherproof Light Junction Box of minimum size 400 mm × 300 mm × 200 mm, having Polycarbonate/FRP enclosure with transparent hinged lid IP65/IP67 protection, UV resistant, flame-retardant and corrosion-resistant, Factory premoulded cable entry or suitable cable gland arrangement, Suitable DIN rail, mounting plate and accessories for mounting the SPD including connecting cupper wires and all accessories as required for complete. | - | Each | 20,583.58 | - |
| 5 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole | 30 | Each | 247 | ₹7,410 |
| 6 | Supply & Fixing of 12 Watt spot or Spike light for (LED light) outdoor IP65, Colour: Red/Green/Warm White. Input Voltage : (85-265V), Diameter; 60mm to be fitted in different locations of Basundhara Area. | 50 | Each | 619.88 | ₹30,993.79 |
| 7 | Supply & Fixing of one number of 25 Amp 300 Watt 12V RGB SMPS Driver. Input Voltage :180-265V AC, Out Put: 12V, 25A outdoor type IP65 and one number of 24A, 12 V, LED RGB Controller in the existing control panel. | - | Set | 2,412.76 | - |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 80 | Mtr | 266 | ₹21,280 |
| 9 | Laying of one number additional PVC insulated and PVC sheathed XLPE power cable of 1.1KV grade of following sizedirect in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering Above 35 sq. mm and upto 95 sq. mm | 300 | Mtr | 95 | ₹28,500 |
| 10 | Supply, laying and fixing of 3Cx2.5 Sq mm industrial flexible (FRLS) insulated cupper power cable of 1.1KV grade of following size on wall surface as required. | 250 | Mtr | 287.79 | ₹71,947.56 |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.38 MB
Tendernotice_2.pdf
PDF • 0.82 MB
BOQ_375477.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .