Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-Finance | ₹1.1 Cr | L1 | Accepted-Finance L1 bidder |
| 2 | L2₹1.1 Cr+₹3.9 L (3.51%)Accepted-Finance | ₹1.1 Cr+₹3.9 L (3.51%) | L2 | Accepted-Finance L2 bidder |
| 3 | L3₹1.2 Cr+₹7.2 L (6.55%)Accepted-Finance | ₹1.2 Cr+₹7.2 L (6.55%) | L3 | Accepted-Finance L3 bidder |
| 4 | L4₹1.2 Cr+₹8.1 L (7.41%)Accepted-Finance | ₹1.2 Cr+₹8.1 L (7.41%) | L4 | Accepted-Finance L4 bidder |
| 5 | L5₹1.2 Cr+₹9.5 L (8.67%)Accepted-Finance | ₹1.2 Cr+₹9.5 L (8.67%) | L5 | Accepted-Finance L5 bidder |
Tender Value
₹1.3 Cr
EMD Value
₹1.3 L
Closing Date
1 Aug 2023, 4:00 pmClosed
SE ETC I, Lucknow
S.E. ETC I, Lucknow
Work
2023_UPTCL_823528_1
Very short term e-tender 32/2023-24
Open Tender
Electrical Works
Piece-work
120 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹1.3 L
17 Aug 2023
22 Jul 2023
2 Aug 2023
22 Jul 2023
1 Aug 2023
22 Jul 2023
Amount
A) Supply of Materials
1) Fabrication, Galvanizing and Supply of 132 KV DC Towers Including Stubs, Extension and Stub - as per Drawing & BOM (DC+5-8.227*2Nos,DC+10 - 10.554*3 Nos.,DC+15-13.259*1Nos and DB+5 - 6.625*1Nos. )
2) Hot Dip galvanized Hexagon Head Transmission Tower Bolts with Suitable Nuts & Washers for above Structures as per BOM.( 4% of tower part))
3) Conductor Accessories
a) Vibration damper suitable for ACSR Panther conductor
b) Double Tension fittings compressed type suitable for ACSR Panther conductor
c) Single Tension fittings compressed type suitable for ACSR Panther conductor
d) Mid span compression joint for ACSR Panther Conductor
e) Repair Sleeves for ACSR Panther Conductor
f) Preformed Armour Rod for ACSR Panther Conductor
4) 7/3.0 mm Earthwire Accessories
a) Tension clamps
b) Suspension Clamp
c) Copper bond dia 12 mm, length 570 mm
d) Vibration Damper for E/W
3) Mid span compression joint
5) Tower Accessories
a) Supply of Number Plates in the size of 165 mm X 150 mm , manufactured out of 16 SWG M.S Sheet with Letters and Numerals enameled Red on White to Number serially the Tower of the Transmission Line, Number Plate indicating Name of Transmission Line in short and Tower number are required 2 No. 16x40 mm HRH Bolts and Nuts with 04 No. lead Washers of 2 mm thickness shall have to be supplied with each Plate. Matching hole of 17.5 mm shall be provided for Fixing up the Plate with Tower. The back side of Plate shall be enamelled Black.
b) Supply of Phase plates in the sets of Red,Yellow,Blue colour Circular disc (both sides enamelled) of long heavy dully made of 16 S.W.G Sheet with provision of 2 Nos. 16x40 mm HRH bolts and nuts with 4 No. lead washers of 2 mm thickness shall have to be supplied with each plate. Matching holes of 17.5 mm shall be provided for fixing up the plate with Tower. The back side of plate shall be enameled Black.
c) Supply of Danger Plates in the size of 380 mm X 250 mm, manufactured out of 16 SWG M.S Sheet showing Sign of Danger shall be supplied. Danger Sign shall be composed of word 'DANGER' written in English Letters of about 35 mm height, 'खतरा' in Hindi Letter about 45 mm height 132000 Volts written in English letters about 30 mm height and Two Human Skulls above two bones shown in cross of size about 70mmX 80mm shown symmetrically all enameled Red on White background 2 No. 16X40 mm HRH Bolts and Nuts with 4 No. lead Washers of 2 mm thickness shall have to be supplied with each Plate. Matching hole of 17.5 mm shall be provided for Fixing up the Plate with Tower. The Back side of Plate shall be enameled Black.
d) Circuit Plate
e) Providing of Pipe type Earthing Equipment set consisting of 32 mm dia 3050 mm long heavy duty perforated 'C' Class G.I Pipe 50 mm x 6 mm size 4750 mm long Galvanized steel Flat and 2 No. 12 mm x 40 mm size G.I Bolts with Nuts & Washers etc. as per technical specification.
B) WORK ASSOCIATED WITH CONSTRUCTION OF NEW LINE PORTION AND INTERCONNECTION WITH EXISTING LINE INCLUDING NECESSARY DISMANTLING :
1) Survey & profiling
2) Check Survey & Peg marking
3) Excavation of foundation excluding back filling & leveling for 02Nos DC+5, 3 Nos. DC+10,01 NosDC+15 & 01Nos. DB+5 towers
4) Stub setting DB type Tower
5) Stub setting DC type Tower
6) Installation of steel reinforcement of concrete foundation including cost of steel bars, cutting , bending & placing etc.
7) Concreting of foundation including cost of arrangement of form boxes, shoring, shuttering & back filling , curing including the cost of cement, sand & stone ballast etc. for 06 Nos. DC type & 02 N0. DB Type Tower (FS Foundation)
8) Transportation of all material from various stores under ETD-I, Lucknowwith loading, unloading & stacking.
9) Erection of towers including proper tightening, fixing of number plates, phase plate & danger plates, bird guard etc.
10) Tack welding of bolts & nuts up to 2nd section
11) Earthing of tower with pipe type earthing including by putting the G.I Pipe at least 600 mm below ground level & at least 3650 mm away from the Tower itself and connecting the G.I Strip of the Pipe with Bolt holes in the Leg Members Joining the bottom most Bracing of the Tower by making about 300 mm dia , 3750 mm deep Pit at a distance of not less than 3650 mm away from the Stubs and finally, filling the Pit with finally broken Coke having the granule sizes not more than 25 mm and Salt in such a way that minimum cover of 125 mm thick Salt Mixed Coke shall be maintained around the Pipe on all sides and the top edge of the Pipe and G.I Strip shall be at least 600 mm below the ground level, complete in all respect as per Technical specifications, with all cost of Men, Materials, Misc, consumables, T&Ps etc. required for the job including the Pipe type Earthing Equipment Set.(02 No. for each Towers to be Earthed)
12) Laying, Stringing, tensioning, Clamping ACSR Panther Conductor( All Six Phase), including hoisting of insulators , fitting of all accessories hardware and accessories i.e. fittings, armour rods,vibration dampers etc. along with all related other works up to re-energisation
13) Restringing,Laying, tensioning, clamping, jointing etc. completed of Earth Wire including fitting of vibration dampers.
14) Anchoring of Section Towers by providing Stay on Cros Arms of Section Tower before removal of old Conductors including suitable fixing of Stay Rod by making C.C. Foundations and removal thereof after completion of works (1 Job per Cross arm)
15) Dismantling of all 6 Phases of existing DC ACSR Panther Conductor, all Hardwere fittings & conductor accessories e.g. armour rod, vibration Dampers, insulator strings etc.of existing line and re-rolling of dismantled conductor on empty drums for re-use, safely transportation of all removed material to UPPTCL stores.
16) De-stringing of Earth Wire 7/10 SWG
17) Cutting of Tack WeldingNUt & Bolt For Safe Dismantelling
18) Dismantling of 132 kV Single Circuit 3Nos A- Type Tower and 1no. B+0 tower
19) Transportation of balance material from site to store at 132 kV S/S Mohan Road, Lucknow along with loading, unloading & stacking .
20) Charges for getting NOC From Electrical Safty Department after completation of the work
Bhagwati Traders
Jyoti Engineering Works
E-VISION INFRATECH
Transtec Engineers and Constructions Co.
Star Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .