Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | Rejected-Technical THIRUVILAKKIL SANATHANAPURAM P O ALAPPUZHA AMBALAPPUZHA TALUK ALAPPUZHA DISTRICT | - | Rejected-Technical QUOTED HIGHER RATE | |
| 3 | Rejected-Technical | - | Rejected-Technical QUOTED HIGHER RATE | |
| 4 | Rejected-Technical KOONAMPALAYIL THULAPPALLI PO PATHANAMTHITTA 686510 | PATHANAMTHITTA | PATHANAMTHITTA | KERALA | 686510 | - | Rejected-Technical QUOTED HIGHER RATE |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Jan 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Office of The Executive Engineer,LIiD and EW Division , Alappuzha Jilla Panchayath
BUILDING
2020_LSGD_402447_2
JP TENDER_D1-2073/18/LSGD/ALPY
Open Tender
Civil Works - Buildings
Item Rate
210 days
PLEASE REFER WORK ITEM DETAILS
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,950
Yes
₹50,000
Yes
13 Oct 2021
26 Dec 2020
11 Jan 2021
26 Dec 2020
7 Jan 2021
26 Dec 2020
90 days
Amount
Renovation Works
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).
od946759/2020_2021 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with<br>Aluminium Composite Panel Cladding, with open grooves for linear as well as<br>curvilinear portions of the building , for all heights and all levels etc. including:<br>a) Structural analysis & design and preparation of shop drawings for pressure<br>equalisation or rain screen principle as required, proper drainage of water to make<br>it watertight including checking of all the structural and functional design.<br>b) Providing, fabricating and supplying and fixing panels of aluminium composite<br>panel cladding in pan shape in metalic colour of approved shades made out of<br>4mm thick aluminium composite panel material consisting of 3mm thick FR grade<br>mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The<br>aluminium composite panel cladding sheet shall be coil coated, with Kynar<br>500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour<br>and shade on face # 1 and polymer (Service) coating on face # 2 as specified using<br>stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer<br>rods etc.<br>c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised<br>with serrations and serrated washers to arrest the wind load movement, fasteners,<br>SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to<br>prevent bi-metallic contacts all complete required to perform as per specification<br>and drawing The item includes cost of all material & labour component, the cost of<br>all mock ups at site, cost of all samples of the individual components for testing in<br>an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall<br>with aluminium composite panel cladding till the handing over of the building for<br>occupation. Base frame work for ACP cladding is payable under the relevant<br>aluminium item.s The Contractor shall provide curtain wall with aluminium<br>composite panel cladding, having all the performance characteristics all complete<br>, as per the Architectural drawings, as per item description, as specified, as per the<br>approved shop drawings and as directed by the Engineer-in-Charge.<br>However, for the purpose of payment, only the actual area on the external face of<br>the curtain wall with Aluminum Composite Panel Cladding (including width of<br>groove) shall be measured in sqm. up to two decimal places.
od947167/2020_2021 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with<br>Aluminium Composite Panel Cladding, with open grooves for linear as well as<br>curvilinear portions of the building , for all heights and all levels etc. including:<br>a) Structural analysis & design and preparation of shop drawings for pressure<br>equalisation or rain screen principle as required, proper drainage of water to make<br>it watertight including checking of all the structural and functional design.<br>b) Providing, fabricating and supplying and fixing panels of aluminium composite<br>panel cladding in pan shape in metalic colour of approved shades made out of<br>3mm thick aluminium composite panel material consisting of 2mm thick FR grade<br>mineral core sandwiched between two Alumini um sheets (each0.25mm thick). The<br>aluminium composite panel cladding sheet shall be coil coated, with Kynar<br>500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour<br>and shade on face # 1 and polymer (Service) coating on face # 2 as specified using<br>stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer<br>rods etc.<br>c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised<br>with serrations and serrated washers to arrest the wind load movement, fasteners,<br>SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to<br>prevent bi-metallic contacts all complete required to perform as per specification<br>and drawing The item includes cost of all material & labour component, the cost of<br>all mock ups at site, cost of all samples of the individual components for testing in<br>an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall<br>with aluminium composite panel cladding till the handing over of the building for<br>occupation. Base frame work for ACP cladding is payable under the relevant<br>aluminium item.s The Contractor shall provide curtain wall with aluminium<br>composite panel cladding, having all the performance characteristics all complete<br>, as per the Architectural drawings, as per item description, as specified, as per the<br>approved shop drawings and as directed by the Engineer-in-Charge.<br>However, for the purpose of payment, only the actual area on the external face of<br>the curtain wall with Aluminum Composite Panel Cladding (including width of<br>groove) shall be measured in sqm. up to two decimal places.
od947277/2020_2021 : Structural Glazing Including Frame with 6mm thick high performance reflective glass- (OD modified 25.2) Designing, fabricating, testing, protection, installing and fixing in position semi<br>(grid) unitized system of structural glazing (with open joints) for linear as well as<br>curvilinear portions of the building for all heights and all levels, including:<br>a) Structural analysis & design and preparation of shop drawings for the specified<br>design loads conforming to IS 875 part III (the system must passed the proof test<br>at 1.5 times design wind pressure without any failure), including functional design<br>of the aluminum sections for fixing glazing panels of various thicknesses, aluminium<br>cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps<br>etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke<br>seals, microwave cured EPDM gaskets for water tightness, pressure<br>equalisation & drainage and protection against fire hazard including:<br>b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of<br>6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3<br>Dimentional movement for achieving perfect verticality and fixing structural glazing<br>system rigidly to the RCC/ masonry/structural steel framework of building structure<br>using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic<br>contacts with nuts and washers etc. of stainless steel grade 316, of the required<br>capacity and in required numbers.<br>c) Providing and filling, two part pump filled, structural silicone sealant and one<br>part weather silicone sealant compatible with the structural silicone sealant of<br>required bite size in a clean and controlled factory / work shop environment ,<br>including double sided spacer tape, setting blocks and backer rod, all of approved<br>grade, brand and manufacture, as per the approved sealant design, within and all<br>around the perimeter for holding glass.<br>d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick<br>and of sizes, shapes and profiles, as required as per the site conditions, to seal the<br>gap between the building structure and all its interfaces with curtain glazing to<br>make it watertight.<br>e) Making provision for drainage of moisture/ water that enters the curtain glazing<br>system to make it watertight, by incorporating principles of pressure equalization,<br>providing suitable gutter profiles at bottom (if required), making necessary holes<br>of required sizes and of required numbers etc. complete. This item includes cost<br>of all inputs of designing, labour for fabricating and installation of aluminium grid,<br>installation of glazed units, T&P, scaffolding and other incidental charges including<br>wastages etc., enabling temporary structures and services, cranes or cradles etc.<br>as described above and as specified. The item includes the cost of getting all the<br>structural and functional design including shop drawings checked by a structural<br>designer, dully approved by Engineer-in-charge.<br>The item also includes the cost of all mock ups at site, cost of all samples of the<br>individual components for testing in an approved laboratory, field tests on the<br>assembled working structural glazing as specified, cleaning and protection till the<br>handing over of the building for occupation. In the end, the Contractor shall provide<br>a water tight structural glazing having all the performance characteristics etc. all<br>complete as required, as per the Architectural drawings, as per item description,<br>as specified, as per the approved shop drawings and as directed by the Engineerin-<br>Charge.<br>Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded<br>aluminium section capping for fixing in the grooves of the curtain glazing and<br>vermin proof stainless steel wire mesh shall be paid for separately under relevant<br>items under this sub-head. However, for the purpose of payment, only the actual<br>area of structural glazing (including width of grooves ) on the external face shall<br>be measured in sqm. up to two decimal places.<br>Note:-2. The following performance test are to be conducted on structural glazing<br>system if area of structural glazing exceeds 2500 Sqm from the certified laboratories<br>accreditated by NABL(National Accreditation Board for Testing and Calibration<br>Laboratories), Department of Science & Technologies, India. Cost of testing is<br>payable separately. The NIT approving authority will decide the necessity of testing<br>on the basis of cost of the work, cost of the test and importance of the work.<br>Performance Testing of Structural glazing system<br>Tests to be conducted in the NBL Certified laboratories<br>1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to<br>+300pa) as per<br>ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”<br>2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing<br>method for a range up to 2000 ml.”<br>3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing<br>method for a range upto 2000 ml”<br>4. Structural Performance Deflection and deformation by static air pressure test<br>(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing<br>method for a range upto 50 mm”<br>5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for<br>Qualitative test” Tests to be conducted on site<br>6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)<br>upto 2000ml”
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.17.1 : Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:R.S. Joists
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
od828376/2020_2021 : Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
6.4.2 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
od956545/2020_2021 : Providing and fixing 12 mm thick frameless toughened glass of approved brand and manufacture for fixing on Walls all complete as per direction of Engineer-incharge
od897370/2020_2021 : Providing and fixing Marine Ply wood marked, to backing or studding with screws etc. complete (Frames, backing or studding to be paid separately).<br>Pre-laminated with decorative lamination on one side and balancing lamination on Other side exterior Grade-I Marine Ply wood18 mm thick confirming
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od827506/2020_2021 : Providing and fixing Wall panelling on Light gauge steel frame work<br>with . Outer face having 6mm thick heavy duty fiber cement board confirming to IS 14862:2000, category<br>IV type A (High pressure steam cured) as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make. .(cost of frame work to be paid for<br>separately).
13.26 : Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
12.59.1 : Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
od825785/2020_2021 : pvc frame with door shutter locally available material.MR
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern
17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
17.10.2.3 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board470x420 mm bowl depth 178 mm
50.18.9.12.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall
50.18.9.13.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.20.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.5 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee
50.18.9.20.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
50.18.9.22.3 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
50.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.6 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
od947357/2020_2021 : Providing and fixing aluminium trafford sheet pre-caoted(size shape and pithc corrugations approved by engineer in charge)0.45mm or nearest modified itemn 12.5 approved by PWD
50.12.2.4 : Providing & fixing Poly carbonate multi wall plain sheet 6 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12m or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical curved surfaces, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.
12.4.2 : Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
50.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters
od897702/2020_2021 : Filling with contractor own earth (excluding rock) in open areas in layers not<br>exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and<br>lift up to 1.5 m as per direction of site Engineer-in-charge.<br>
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
od956308/2020_2021 : Supply and fixing 600mm dia S.S Turbo Ventilator Over Air shaft Roof
od958009/2020_2021 : Engaging Man Mazdoor
BAIJU V
C F GEORGEKUTTY
jibin joseph
Bidder Name
BAIJU V
C F GEORGEKUTTY
jibin joseph
ABDUL RAHEEM M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_572398.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .