| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAdmitted-Finance 501 SHANTI RESIDENCY II KRUSHNA NAGAR NR NARDAI BRAHM SAMAJ JAMNAGAR 361 006 | JAMNAGAR | GUJARAT | 361006 | ₹44.7 L | L1 | Admitted-Finance |
| 2 | L2₹47.4 LAdmitted-Finance HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | ₹47.4 L | L2 | Admitted-Finance |
| 3 | L3₹50.0 LAdmitted-Finance PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | ₹50.0 L | L3 | Admitted-Finance |
| 4 | L4₹51.1 LAdmitted-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹51.1 L | L4 | Admitted-Finance |
| 5 | L5₹53.0 LAdmitted-Finance | ₹53.0 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | m/s prakash enterprise L3 | Vijay Construction Co L1 | SURESH ELECTRICALS L4 | roxy enterprise | roxy enterprise L2 | SANVI ASSOCIATES L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for servicing and overhaulving of ACB upto 1600 Amps Capacity including all consumables maintainance kit and required minor parts including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable all as specified and directed by Engineer in Charge. | 2 | Each Job | 7,000 ₹14,000 | 8,500 ₹17,000 | 2,500 ₹5,000 | 18,500 ₹37,000 | 18,500 ₹37,000 | 25,000 ₹50,000 |
| 2.00 | S & F in repairs Digital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/Schneider. | 9 | Each | 1,400 ₹12,600 | 1,350 ₹12,150 | 2,500 ₹22,500 | 1,200 ₹10,800 | 1,200 ₹10,800 | 6,500 ₹58,500 |
| 3.00 | S&F in repairs Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, progaramable type and all as specified and directed. Make:AE/MECO/Schneider.. | 9 | Each | 1,750 ₹15,750 | 1,350 ₹12,150 | 3,000 ₹27,000 | 9,000 ₹81,000 | 9,000 ₹81,000 | 5,600 ₹50,400 |
| 4.00 | S&F in repairs Trip rod of ACB all as specified and directed. | 2 | Each | 580 ₹1,160 | 1,200 ₹2,400 | 1,000 ₹2,000 | 3,600 ₹7,200 | 3,600 ₹7,200 | 2,500 ₹5,000 |
| 5.00 | S&F in repairs Trip Latch of ACB all as specified and directed. | 2 | Each | 550 ₹1,100 | 850 ₹1,700 | 2,000 ₹4,000 | 4,200 ₹8,400 | 4,200 ₹8,400 | 900 ₹1,800 |
| 6.00 | S&F in repairs Door interlock of ACB all as specified and directed. | 2 | Each | 420 ₹840 | 850 ₹1,700 | 2,000 ₹4,000 | 3,000 ₹6,000 | 3,000 ₹6,000 | 1,200 ₹2,400 |
| 7.00 | S&F in repairs Closing coil DC Adaption kit of ACB all as specified and directed. | 2 | Each | 3,000 ₹6,000 | 850 ₹1,700 | 1,500 ₹3,000 | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,500 ₹9,000 |
| 8.00 | S&F in repairs pole connector kit of ACB all as specified and directed. | 2 | Each | 3,500 ₹7,000 | 1,550 ₹3,100 | 3,500 ₹7,000 | 6,200 ₹12,400 | 6,200 ₹12,400 | 12,500 ₹25,000 |
| 9.00 | Supply and laying of Stone aggregate of size 40 mm /20 mm and laid in 4 pole structure/ DG set location / sub station area and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge | 60 | Cum | 2,100 ₹1.3 L | 1,500 ₹90,000 | 900 ₹54,000 | 1,850 ₹1.1 L | 1,850 ₹1.1 L | 3,500 ₹2.1 L |
| 10.00 | S&F in repair Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with bus bar and one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.
Make: Sintex / National / Hensel or equivalent model of makes approved by GE. | 100 | Each | 1,600 ₹1.6 L | 1,250 ₹1.3 L | 3,000 ₹3 L | 1,200 ₹1.2 L | 1,200 ₹1.2 L | 3,000 ₹3 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
9 May 2026, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
MAINTENANCE/ REPAIR/ REPLACEMENT OF STREET AND SOLAR LIGHTS, LIGHT POLES, UG CABLE LINKS, FEEDER PILLAR BOXES, APFC PANELS INCLUDING PREVENTIVE MAINT AND ALLIED WORKS AT NOFRA, NAUSENA BAGH AND MES COMPLEX
2026_MES_760008_1
9365/PBR/E8
Open Tender
Electrical and Maintenance Works
180 days
GE Navy Porbandar
Please see tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹90,000
Yes
19 May 2026
11 Apr 2026
11 May 2026
11 Apr 2026
9 May 2026
26 Apr 2026
11 Apr 2026 - 25 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
M & L for servicing and overhaulving of ACB upto 1600 Amps Capacity including all consumables maintainance kit and required minor parts including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable all as specified and directed by Engineer in Charge. | - | Each Job | - | - | |
S & F in repairs Digital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/Schneider. | - | Each | - | - | |
S&F in repairs Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, progaramable type and all as specified and directed. Make:AE/MECO/Schneider.. | - | Each | - | - | |
S&F in repairs Trip rod of ACB all as specified and directed. | - | Each | - | - | |
S&F in repairs Trip Latch of ACB all as specified and directed. | - | Each | - | - | |
S&F in repairs Door interlock of ACB all as specified and directed. | - | Each | - | - | |
S&F in repairs Closing coil DC Adaption kit of ACB all as specified and directed. | - | Each | - | - | |
S&F in repairs pole connector kit of ACB all as specified and directed. | - | Each | - | - | |
Supply and laying of Stone aggregate of size 40 mm /20 mm and laid in 4 pole structure/ DG set location / sub station area and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge | - | Cum | - | - | |
S&F in repair Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with bus bar and one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.
Make: Sintex / National / Hensel or equivalent model of makes approved by GE. | - | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_851280.xls
BOQ • 0.34 MB
9365_Gen_Page.pdf
Tender Documents • 1.26 MB
Download all tender documents and submit your bid