Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Qualified 23 WHITE CASTLE 34 35 UNION PARK CHEMBUR MUMBAI 400071 | MUMBAI | MUMBAI | MAHARASHTRA | 400071 | Qualified Qualified |
| 2 | Qualified PLOT NO 25 SURVEY NO 13 14 17 18 J P SOFTWARE PARK KONNAPANA AGRAHARA VILLAGE BEGUR HOBLI ELECTRONIC CITY PHASE 1 HOSUR ROAD | Qualified Qualified |
Tender Value
₹11.7 Cr
Closing Date
21 Oct 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ran Vijay Singh (CM
Power Grid Corporation of India Ltd., Northern Regional Telecom Control Center, 400/220 KV S/s Maharani Bagh, Behlolpur Khadar, Opp. ISBT Sarai Kale Khan, New Delhi 110013
Package-Z: Access Equipment Package for augmentation of Telecom Backbone and Access Network
NRTCC/CS/21-22/Access Equipment/PKG-Z/1288
Open
Miscellaneous
Fixed-rate
New Delhi
₹25,000
26 Oct 2021
20 Sept 2021
26 Oct 2021
20 Sept 2021
21 Oct 2021
20 Sept 2021
(Period in weeks from LOA)
Batch-1*
Batch-2*
Batch-1 (150 Equipments)
Lot-1 (75 Equipments)
Lot-2 (75 Equipments)
Batch-2 (74 Equipments)
Lot-1 (50 Equipments)
Lot-2 (24 Equipments)
POWERGRID may increase/ decrease the no of Equipment in each LOT based on requirement.
POWERGRID may increase/ decrease the no of BATCH/ LOT for delivery of equipment, based on requirement.
POWERGRID may advance/ delay in the implimentation of TMN
BoQ of 'Package-Z: Access Equipment Package'
AC Power Module
DC Power Module
10GBASE-ZR XFP
10GBASE-ER XFP
10G BASE-LR XFP
10G BASE-SR XFP
1000 BaseLX SFP
Gbe Electrical (1000 base-T) SFP
BI-DI XFP (10G) 60 KM PAIR:END A
BI-DI XFP (10G) 60 KM PAIR:END Z
1000BASE-EX SFP (40km)
1000BASE-ZX SFP (80km)
1000BASE-EZX SFP (120km)
1000BASE-EZX+ SFP (170 Km)
Cabinet Standard
Amplifier Solution Set for 30 dB
Amplifier Solution Set for 35 dB
Amplifier Solution Set for 40 dB
Amplifier Solution Set for 45 dB
The ‘Set’ consists of all necessary amplifiers, pluggable Optics for respective equipment, Patch cords, power cables, Communication/ DCN cable accessories and any other items as per TS, for one end of the link i.e. POWERGRID shall order two (02) sets for implementation of one (01) link.
Amplifier Solution Set for 50 dB (200 Km)
Server
Work stations
Other hardwares
(One set will comprise of all necessary hardwares e.g. gateway NE, Router/Ethernet swtich/Converter etc. as required.)
System software
(One set will comprise of all necessary hardwares e.g. computer system, gateway NE, Router/Ethernet swtich/Converter etc. as required.)
Application software
Server
Work stations
Other hardwares
(One set will comprise of all necessary hardwares e.g. gateway NE, Router/Ethernet swtich/Converter etc. as required.)
System software
Application software
(One set will comprise of all necessary hardwares e.g. computer system, gateway NE, Router/Ethernet swtich/Converter etc. as required.)
Training
Installation of Equipment
Installation of Cabinet
Installation of Amplifier Solutions
Installation of Server (Main)
Installation of Work Station (Main)
Installation of Other Hardwares (Main)
Installation of System Software (Main)
Installation of App. Software (Main)
Installation of Server (Backup)
Installation of Work Station (Backup)
Installation of Other Hardwares (Backup)
Installation of System Software (Backup)
Installation of App. Software (Backup)
Installation of Remote Workstation (H/W)
Installation of Remote Workstation (S/W)
SERVICE:24x7 Shift Operations
SERVICE:Day time Operations (9:00 to 18:00 Hrs)
Maintenance Services for 01 (One) Year during Defect Liability Period
Annual Maintenance Charges for 05 (Five) Years after Defect Liability Period
Power Grid Corporation of India Ltd. Telecommunication Backbone and Access Augmentation Project Volume II - Appendcies for Package-Z: Access Equipment Package
Appendix D
Data Requirement Sheets
The following sets of Data Requirement Sheets are required to be filled up by the bidders to aid in the evaluation process. The response shall be brief and to the point and shall be supported by the printed product description and other literature. However, more parameters may be required to provided in DRS during detailed engineering.
NOTE- DRS for each type of offered equipment shall be filled separately by the bidder & attached with the bid
DATA REQUIREMENTS SHEETS for MPLS-TP
Manufacturer:
Model #:
Equipment Type (Add column, if required)
Dimension (mm)
Weight (kg)
Max. Power Supply (W)
Voltage Range (V)
Please mention all Equipment (or their modules, if modular)
Dimension (mm)
Weight (kg)
Typ. Power (W)
Max. Power (W)
(Add rows, if required)
MPLS Tunnel1:1 Switch Time
LAG Switch Time
Max. Number of Routing
Number of MPLSTunnel
Max. Number of MSP Group
Max. Number LAG Group
Max. Number LSP Protection Group
Max. Number Wrapping
Number PW
Number E-line
Number of E-LAN Service
Number of E-Tree Service
Static MAC Address
Accuracy of CAR/Shaping
Number of CAR
Number of Multicast
Number of PTP Interface
Number of Sync ETH Interface
VLAN (IEEE 802.1Q)
Q-in-Q (IEEE 802.1ad)
9000 bytes jumbo frame
VLAN manipulation: stack/switch/strip
IGMP snooping (V1/V2/V3)
Flow control (IEEE 802.3x)
MPLS-TP OAM (G.8113.1/G.8113.2)
ITU-T Y.1731 End-to-end Performance Monitoring and AIS
802.3 Link OAM
802.1 CFM OAM
LSP 1:1 linear protection
LSP SNC protection
LSP ring protection
Single segment (SS) pseudowire 1:1 protection
Multi-segment (MS) pseudowire 1:1 protection
802.1AX Link Aggregation (UNI/NNI) with LACP
RSTP (IEEE 802.1Q)
Link Pass-Through (LPT)
L2 Classification: VLAN,PRI, MAC address, TPID
L3 Classification: IP address,DSCP, port number, TOS
Connection Admission Control (CAC)
Policing (CIR, CBS, EIR, and EBS; ColorBlind Mode and Color-Aware Mode)
Shaping
Congestion Avoidance: WRED
Transport and storage
Operation for long term
Operation for short term
System Availability
Secure Shell (SSHv2) support for remote login and file transfer
SFTP (Secure File Transfer Protocol)
Allows the administrator to define actions permitted for each user
Auto-logout function to logout the idle session
Bit Rate
Frequency Range
Frequency Spacing
Frequency Stability
Transmission Distance
Connector Type
Transmitter
Laser Type
Mean Output Power(Max)
Mean Output Power(Min)
Minimum Extinction ratio
Eye Mask
SBS Suppression
Optical Path
Dispersion(Max)
Optocal retun Loss(Min)
Discrete reflectance (Max)
DGD(Max)
Receiver
Mean input power Load
Reflectance of receiver
Sensitivity path panelty
Application Code
Fiber type
Modulation
Supported Distance Range [km]
Laser Types
Central Wavelength [nm]
Max. Spectral Width [nm]
Average Launch Power [dBm]
Extinction Ratio [dB]
Receiver Types
Mini. Overload [dBm]
Receiver Sensitivity @BOL [dBm]
Receiver Sensitivity @EOL [dBm]
Optical Path Penalty [dB]
Max. Reflect. of receiver [dB]
Digital Diagnostics Function
ITU-T G.691 Mask Margin
Unidirectional
Bidirectional (single fibre operation)
Nominal supply voltage:
Power supply variation
Guaranteed performance:
Operation without damage:
Polarity:
Whether 220 Vac mains operation capability inbuilt
List derived DC voltages:
Module cut of power values
Total power consumption (Fully equipped incl. service channels)
Unprotected terminal:
1+1 Protected terminal:
1+1 APS protection provided?
MTBF of power supply unit:
Ultimate power delivery capacity
Are the following protections provided?
Whether proposed equipment has distributed Power Supply?
Provide AC & DC power supply requirement for each of the proposed equipment.
Provide Procedure to convert OLA and Repeaters to Add Drop Multiplexer
Power Distribution in Subrack by power module
Expected life of Equipment
a) 10G on G.652 and G.653 Fiber
With Amplifiers
MEF CE 2.0 Compliant: E-Line, E-LAN,E-Tree, E-Access
ETSI EN 300 386 V1.6.1/EN 55022(2010)
Others
PROTECTION SWITCHING
List the type of Protection Schemes supported by the Equipment
Discuss the proposed protection scheme
(Add rows, if required)
Switching modes available(For Modules)
Manual?
Remote/network management?
Switching priority:
switchover & switchback criteria:
Switch option mode & status indicators:
Switching Time
Nominal:
Maximum:
List all alarms supported by Equipment:
Number of Sub-Racks (including DC/DC converters, O/W muldem etc.) required for Unprotected Terminal:
1:1 Protected Terminal:
Sub-Rack mounting options:
Sub-Rack clearance requirements
Top * Bottom * Sides:
Front Access:
Rear Access:
Sub-Rack color and finish
Cabinet options available
Slim rack?
Others (specify)?
Whether Truncated Cabinet Available?
Fill for all Cabinet Types Proposed
Protection Class (IP Class):
Rack Color and Finish:
Altitude Installed:
Air flow in subrack (diagram required)
Describe Ventilation requirements:
Describe dustproofing provisions:
Electromagnetic compatibility (List standards & severity levels) (Submit Test Reports)
Noise Standards supported (Submit Test Reports )
Environmental standards supported (Submit Test Reports)
Output power Range
Receive Maximum/Minimum power
Laser class
Wavelength range
Gain ripple
EDFA tilt for minimum gain ripple
Noise figure
Gain flatness
Raman Amplifier safey precations and measure
VOA range
Amplifier management
Network Management
DATA REQUIREMENTS SHEETS for L2 Switch
Manufacturer:
Model #:
Equipment Type
Dimension (mm)
Weight (kg)
Max. Power Supply (W)
Voltage Range (V)
Ports
Technical Specifications
Switching capacity nonblocking
Forwarding rate
Jambo Frame
Flash Memory
MAC table size
Number of VLANs
Type of VLAN
HOL blocking
Web user interface
CLI interface
SNMP MIBs
Firmware upgrade
Port mirroring
Other management
IEEE 802.1X
Access control
Access security
Link aggregation
Storm control
Spanning tree
IGMP snooping
Priority levels
Scheduling
Class of service
Per flow QoS
Rate limiting
Standards
Application Code
Fiber type
Modulation
Supported Distance Range [km]
Laser Types
Central Wavelength [nm]
Max. Spectral Width [nm]
Average Launch Power [dBm]
Extinction Ratio [dB]
Receiver Types
Mini. Overload [dBm]
Receiver Sensitivity @BOL [dBm]
Receiver Sensitivity @EOL [dBm]
Optical Path Penalty [dB]
Max. Reflect. of receiver [dB]
Digital Diagnostics Function
ITU-T G.691 Mask Margin
Transceiver form factor
Transmission speed
Connector type
Applicable cable and maximum transmission distance
Transport and storage
Operation for long term
Operation for short term
Unidirectional
Bidirectional (single fibre operation)
Nominal supply voltage:
Power supply variation
Guaranteed performance:
Operation without damage:
Polarity:
Whether 220 Vac mains operation capability inbuilt
List derived DC voltages:
Module cut of power values
Total power consumption (Fully equipped incl. service channels)
Unprotected terminal:
1+1 Protected terminal:
1+1 APS protection provided?
MTBF of power supply unit:
Ultimate power delivery capacity
Are the following protections provided?
Whether proposed equipment has distributed Power Supply?
Provide AC & DC power supply requirement for each of the proposed equipment.
Provide Procedure to convert OLA and Repeaters to Add Drop Multiplexer
Power Distribution in Subrack by power module
PROTECTION SWITCHING
List the type of Protection Schemes supported by the Equipment
Discuss the proposed protection scheme
Switching modes available(For Modules)
Manual?
Remote/network management?
Switching priority:
switchover & switchback criteria:
Switch option mode & status indicators:
Switching Time
Nominal:
Maximum:
List all alarms supported by Equipment:
Number of Sub-Racks (including DC/DC converters, O/W muldem etc.) required for Unprotected Terminal:
1:1 Protected Terminal:
Sub-Rack mounting options:
Sub-Rack clearance requirements
Top * Bottom * Sides:
Front Access:
Rear Access:
Sub-Rack color and finish
Cabinet options available
Slim rack?
Others (specify)?
Whether Truncated Cabinet Available?
Fill for all Cabinet Types Proposed
Protection Class (IP Class):
Rack Color and Finish:
Altitude Installed:
Air flow in subrack (diagram required)
Describe Ventilation requirements:
Describe dustproofing provisions:
Electromagnetic compatibility (List standards & severity levels) (Submit Test Reports)
Noise Standards supported (Submit Test Reports )
Environmental standards supported (Submit Test Reports)
DATA REQUIREMENT SHEETS FOR AMPLIFIER SOLUTIONS & OPTICAL AMPLIFIERS
Manufacturer: ______________________________
Amplifier Solution
Span Loss (dB)
GENERAL PARAMETERS
(Fill for All Type of Amplifiers requred for above solutions)
Type of Amplifier:
Source Power Supply requirements
Volts:
Current:
Gain medium:
Small Signal Gain:
Connection loss to transmission fibre:
Insertion Loss:
System Noise Figure:
Type of pump laser:
Pumping Wavelength:
Bit-Rate distance product:
Type of optical coupler:
Type of optical isolator:
Operating optical bandwidth:
Polarisation Gain Dependence:
Can the same optical amplifier Operate at:
Operating Bit Rates
Lower Limit:
Upper Limit:
"F" Type interface?
(Add rows to fill details about all type of Amplifiers)
POWER AMPLIFIER, PRE AMPLIFIER, LINE AMPLIFIER (ALL PROPOSED TYPES)
Optical Input:
Signal wavelength:
Signal input power (max):
Signal input power (min):
End of Life :
Spectral width (-20 dB from peak):
Connector type:
Pulse shape:
Optical Reflectance:
Optical Output:
Signal output power (max):
Signal output power (min):
End of Life:
Connector type:
List and describe Monitor, Control and Alarm Points:
Describe Network Management Interface provisions:
Complete Accessibility from TMN
Accessibility as a Modules/ Card of the main Equipment in NMS?
Accessibility as a Sub-Equipment in the NMS?
Input Power Measurement via NMS?
Output Power Measurement via NMS?
Unreachability Alarm in NMS?
DATA REQUIREMENTS SHEETS for TMN
Manufacturer: _____________________________
Model Name & #:_____________________________
Whether all types of offered equipment are manageable from single TMN on a seamless end-to-end basis.
MPLS-TP
L2 Switch
Amplifiers
Hardware Configuration at Main Control Centre, including details of Processors, LAN, Routers, Printers etc.
Hardware Configuration at Back-up control centre including details of Processors, LAN, Routers, Printers etc
Describe the flow of data from Network Element to the Main and Back-up control centre, providing details of all the network components in between.
Describe features of TMN including:
Configuration Management
Fault Management
Performance Management
Security Management
Inventory Management
Software Management
Describe communication network required for TMN
Whether Back-up control centre can function independently?
Whether changes implemented by Main Control center automatically updated at Back-up Control centre and vice versa?
Describe configuration of the Voice Network
Describe Remote Access Solution
Solution Supports:
Storage of such logs/audit trail
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
0 Cover Page-III.doc
doc • 0.11 MB
1 First Envelope Attachments and Bid Forms Vol- III (Pkg-Z).xls
xls • 2.82 MB
10 Attachment-25_Affidavit for self-certification.DOCX
docx • 0.02 MB
11 Attachment-26_Declaration regarding event encountered pursuant to ITB Clause 2.1.docx
docx • 0.03 MB
12 Attachment-27_Certificate by Bidder.docx
docx • 0.02 MB
13 Attachment-28_Bid securing Declaration.docx
docx • 0.02 MB
14 Legends for Units.pdf
pdf • 0.03 MB
2 Second Envelope Price Schedule Vol-III.xls
xls • 1.71 MB
3 Attachment-3(QR).DOCX
docx • 0.04 MB
4 Attachment-8_Manufacturer Authorization Form.DOCX
docx • 0.02 MB
5 Attachment-20_KMP Declaration.DOCX
docx • 0.02 MB
6 Attachemnt-21_Affidavit for Self-Certification_PPP-MII.DOCX
docx • 0.02 MB
7 Attachment-22_Certificate by Auditor.docx
docx • 0.02 MB
8 Attachment-23_E-RA Compliance.docx
docx • 0.02 MB
9 Attachment-24_Authorization certificate issued by Domestic Manufacturer.docx
docx • 0.02 MB
0 Cover Page-II.doc
doc • 0.11 MB
01_Vol-II Sec_01.doc
doc • 0.17 MB
02_Vol-II Sec_02.docx
docx • 0.09 MB
03_Vol-II Sec_03.doc
doc • 0.15 MB
04_Vol-II Sec_04.doc
doc • 0.09 MB
05_Vol-II Sec_05.doc
doc • 0.22 MB
06_Vol-II Sec_06.doc
doc • 0.11 MB
07_Vol-II Sec_07.doc
doc • 0.14 MB
08_Vol-II Appendix-A cover page.docx
docx • 0.03 MB
09_Appendix-A (Implementation Plan).xls
xls • 0.11 MB
10_Vol-II Appendix-B Cover Page.docx
docx • 0.03 MB
11_Appendix-B (Telecom Map).pdf
pdf • 0.60 MB
12_Vol-II Appendix-C cover page.docx
docx • 0.03 MB
13_Appendix-C (BoQ).xlsx
xlsx • 0.10 MB
14_Vol-II Appendix-D Cover Page.docx
docx • 0.03 MB
15_Appendix-D (DRS).xlsx
xlsx • 0.25 MB
16_Vol-II Appendix-E cover page.docx
docx • 0.03 MB
17_Appendix-E (DoT Agreement).doc
doc • 0.19 MB
~$ Section - V SCC Vol- I.docx
docx • 0.00 MB
0 Cover Page-I.doc
doc • 0.11 MB
1 Main Index.doc
doc • 0.03 MB
10 Annexure-I to Section-V SCC.pdf
pdf • 0.63 MB
11 Appendix-I to Section - V SCC.pdf
pdf • 0.35 MB
12 Section - VI Sample Forms and Proceedures (FP).doc
doc • 0.57 MB
13 GEM_Availability Report.pdf
pdf • 0.04 MB
2 Section - I Invitation for Bids (IFB).doc
doc • 0.09 MB
3 Section - II ITB SSTE S_I Rev 5-DCB-Mjn.pdf
pdf • 1.95 MB
4 Section - III BDS.docx
docx • 0.06 MB
5 Annexure-A to Section - III BDS (QR).docx
docx • 0.03 MB
6 Annexure-B to Section - III BDS (e-RA Method).pdf
pdf • 0.28 MB
7 Annexure-C to Section - III BDS (e-RA-Notice).docx
docx • 0.03 MB
8 Section - IV GCC -S_I Rev 3-DCB.pdf
pdf • 1.93 MB
9 Section - V SCC.docx
docx • 0.05 MB
2 Attachment-14_Integrity_pact_Rev_1.docx
docx • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .