| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC NIL | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹47.5 L+₹2.8 L (6.16%)Rejected-Finance MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹48.0 L+₹3.2 L (7.18%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹48.5 L+₹3.7 L (8.38%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹49.1 L+₹4.4 L (9.74%)Rejected-Finance NIL | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹47.7 L
EMD Value
₹95,500
Closing Date
25 Sept 2024, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Charali
Repairs Maintenance of DG Set with AMF Panel at Zone 5 and Zone 1 A B C Zone 1 3 A and B Zone 2 and Zone 4 under GE S Tezpur
2024_MES_670287_1
8867
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹95,500
Yes
27 Nov 2024
2 Sept 2024
27 Sept 2024
2 Sept 2024
25 Sept 2024
17 Sept 2024
2 Sept 2024 - 10 Sept 2024
Amount
Maint and servicing of DG set 320-400 KVA conopy type with AMF Panel (if installed ), through authorise service agency of OEM , including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of POL tank and radiator etc all as specified and directed. Make - Kirloskar/cummins/greaves/Ashok Leyland / As per OEM Note:- 1. spares required for above maint will be measured and paid separately under relevent items of Schedule. 2. All breakdown calls should be attended.
All as per Item No-1 Above but for DG set of capacity 180-250 KVA
All as per Item No-1 Above but for DG set of capacity 125-160 KVA
All as per Item No-1 Above but for DG set of capacity 40-100 KVA
All as per Item No-1 Above but for DG set of capacity 25-35 KVA
S & F in repair Fuel filter for 300-400 KVA DG set, Make : As per OEM
S & F in repair Fuel filter for 125-250 KVA DG set,Make : As Per OEM
S & F in repair Fuel filter for 25-100 KVA DG set,Make : As Per OEM.
S & F in repair Lub oil filter for 300-400 KVA DG set,Make : As Per OEM.
S & F in repair Lub oil filter for 125-250 KVA DG set,Make : As Per OEM
S & F in repair Lub oil filter for 25-100 KVA DG set,Make : As Per OEM
S & F in repair Air cleaner filter ( inner and outer ) for 300-400 KVA DG set, Make : As Per OEM.
S & F in repair Air cleaner filter (inner and outer ) for 125-250 KVA DG set, Make : As Per OEM
S & F in repair Air cleaner filter (inner and outer ) for 25-100 KVA DG set, Make : As Per OEM
S & F in repair Bypass filter for 300-400 KVA DG set, Make : As Per OEM.
S & F in repair Bypass filter for 125-250 KVA DG set, Make :As Per OEM
S & F in repair Bypass filter for 25-100 KVA DG set, Make : As Per OEM
S & F in repair V belt for 300-400 KVA DG set, Make : As Per OEM
S & F in repair V belt for 125-250 KVA DG set, Make : As Per OEM
S & F in repair V belt for 25-100 KVA DG set, Make : As Per OEM
S & F in repair Display control panel ( Base card) for 25 to 100 kva DG set,Make : As Per OEM.
S & F in repair Display control panel (Base card) for 125 to 250 kva DG set,Make : As Per OEM.
S & F in repair Display control panel (Base card) for 300 to 400 kva DG set,Make : As Per OEM.
S & F in repair Fuel actuator with O Ring for 300 to 400 kva DG set,Make : As Per OEM
S & F in repair Key switch for 25 to 400kva DG set,Make : As Per OEM
S & F in repair coolant temperature sensor (coolent control safety) for 25 to 400kva DG set,Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 25 to 100 kva DG set,Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 125 to 250 kva DG set,Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 300 to 400kva DG set,Make : As Per OEM
S & F in repair Control assy main generator panel any type for 25 to 100 kva DG set,Make : As Per OEM
S & F in repair Control assy main generator panel any type for 125 to 250 kva DG set,Make : As Per OEM
S & F in repair Control assy main generator panel any type for 300 to 400 kva DG set,Make : As Per OEM
S & F in repair Lube oil pressure sensor adaptor (oil control safety ) 25 to 400 kva DG set,Make : As Per OEM
S & F in repair Stop solenoid switch 12 Volts . Make As Per OEM
S & F in repair Stop solenoid switch 24 Volts. Make- As Per OEM
Supply & Fill Coolant for radiators complete all as specified and directed. Make- As Per OEM
S & F in repair Turbo charger for 25-100 capacity DG set complete all as specified. Make- As Per OEM
S & F in repair Turbo charger for 125-250 capacity DG set complete all as specified. Make- As Per OEM
S & F in repair Turbo charger for 300-400 capacity DG set complete all as specified. Make- As Per OEM
Supply & Fill engine oil multi grade 15W40 all as specified and directed. (Make ELF Oil/ Castrol /HP or equivalent of OEM make)
S & F in repair Automatic Voltage Regulator fit for 25-100 capacity DG set complete all as specified. Make- As Per OEM
S & F in repair Automatic Voltage Regulator fit for 125-250 capacity DG set complete all as specified. Make- As Per OEM
S & F in repair Automatic Voltage Regulator fit for 300-400 capacity DG set complete all as specified. Make- As Per OEM
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to and including 100 KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 125-250 KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 300-400KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Disconnecting the electric connection of Alternator of capacity 25-100 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity 125-250 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity 300-400 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
S & F in repair Lub Oil cooler plate complete all as specified Make- As Per OEM
S & F in repair Lub Oil pressure gauge pipe of required standard size complete all as specified Make- As Per OEM
S & F in repair Oil spray nozzle assembly complete all as specified Make- As Per OEM
S & F in repair Piston assembly of 25 - 400 KVA DG Set complete all as specified Make- As Per OEM
S & F in repair Main Bearing of various sizes for DG set of different capacity complete all as specified Make- As Per OEM
S & F in repair Water temp switch complete all as specified Make- As Per OEM
S & F in repair Lub Oil pump high discharge of required standard size complete all as specified Make- As Per OEM
S & F in repair of field coil assembly for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of Eye bolt for 25-400 KVA DG set,Make- As Per OEM.
S & F in repair of fan key for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of fan assembly for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of fan for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of Circlip for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of DE Bearing for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of Brush holder spindle for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of NDE bearing cap for125/100/75/62.5kva DG set,Make- As Per OEM
S & F in repair of Slipring assembly for 25 -400 KVA DG set Make- As Per OEM.
S & F in repair of Exicitation (CX) unit for 25-100 KVA DG set, Make- As Per OEM
S & F in repair of Exicitation (CX) unit for 125 - 250 kva DG set,Make- As Per OEM
S & F in repair of Exicitation (CX) unit for 300-400 kva DG set,Make- As Per OEM.
S&F battery terminal cable , copper conductor multi strand, unsheathed, single core 25sqmm, 1.5 mtr long each for negative and positive terminal fixed/solder with battery terminal clamp and copper lugs each side of cable sitable for 180 AH Battery (Set of 2 nos.) complete all as specified and directed.
Taking down unserviceable battery and supply and fixing 12 volt, 180 AH battery complete all as specified and directed.
Taking down unserviceable battery and supply and fixing 12 volt, 100 AH battery complete all as specified and directed.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc for 25-160 KVA capacities of DG Set.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc for 200-400 KVA capacities of DG Set.
Taking down the unserviceable radiator for 25-160 KVA from engine, transportation to the workshop dismantling the radiator, repair the tank /storage portion incl necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing in to the existing position & on the engine and testing complete.
Taking down the unserviceable radiator for 200-400 KVA from engine, transportation to the workshop dismantling the radiator, repair the tank /storage portion incl necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing in to the existing position & on the engine and testing complete.
Taking down unserviceable self starter and supply and fixing 24 volt, self starter 24 volt dc complete all as specified. Make- As Per OEM
Taking down unserviceable self starter and supply and fixing 12 volt, self starter 24 volt dc complete all as specified. Make- As Per OEM
Repair, transporting, taking down and servicing of self starter 12/24 volt dc at authorised service centre including refixing the same and testing complete as directed
Maintanence and serviceing the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in panel for autometic operation through relay, contactor, timer, sensor etc all as directed
S & F in repair of Digital multi function meter suitable for AMF panel Make- As Per OEM
S & F in repair of indicator lamp (R,Y & B) suitable for AMF panel Make :- L&T or as approved by GE.
S & F in repair of three pole power contractor type MNX-250 with Aux contracts 2 Nos 2 NC , suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of three pole power contractor type MNX-300 with Aux contracts 2 Nos 2 NC , suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of three pole power contractor type MNX-550 with Aux contracts 2 Nos 2 NC , suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of AC Control contactor - M00AC - 15 4A at 415 Volt suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of DC control contactor M00AC 15 4A at 415 vilt suitable for AMF panel complete.Make :- L&T or as approved by GE.
S&F Manual change over switch fitted in sheet steel enclosure 400 Amp, 4P 415V, 50 Hz with after disconnecting all electrical connections including dismantling old unservicealble and making necessary electrical connections complete all as spcecified and as directed. Make : Havells cat code IHCNFO0400/Legrand/Schnider/L&T
All as per item No. 88.00 here-in-before but of capacity 250 amps (Make : Havells cat code IHCNFO0250/Legrand/Schnider/L&T
All as per item No. 88.00 here-in-before but of capacity 100 amps amps (Make : Havells cat code IHCNFO0100/Legrand/Schnider/L&T
M & L for alteration of existing emmission system and fixing of exhaust emission system of DG set and supply and fix new Retrofit for emission control Diesel Generator emission particulate purification device also known as Retrofit Emission control device or (RECD) equipment reducing diesel particulate matter and other emission gases as per under mentioned technical specification for 30-50 KVA DG Set complete all as specified and directed by Engr-In-Charge. (Akash) Make:- Novorbis Itus Pvt Ltd Technical Specification:- (i). Type of emission device ( working principle of PM reduction active element): Electrostatic Percipitation (ESP). (ii) Emmission limits as per CPCB-II norms : PM 2.5≤0.2 g/kW-hr, Smoke limit (Light Absorption Co-efficient ≤0.7m-1. (iii) Particulate Matter capturing efficiency : Greater than 70%. (iv) Back pressure on engine : Their should be no back pressure from RECD to Engine Exhaust System. (v) Material of construction : SS202 for Inlet chamber, Outer Body coated MS. (vi) Emmission monitoring from stack shall be tested from any NABL approved lab. (vii) RECD's power requirement : less than 1% of capacity used for operation. (viii) Cleaning Mechanism : Automatic cleaning of ESP through any solvent or water. (ix) Noise emission: No increase in noise level after installation of retrofit device. Note:- i. The Output result of the RECD should be as per CPCB-II Norms and the OEM/manufacture should have valid type CPCB approval certificate. ii. The rate are inclusive of T&P items such as crane/hydra etc. iii. The above scope includes Emission control system with PRV, Inlet and outlet pipe and Electric panel and all accessories. iv. The device should not have any by-pass arrangement. v. Genset hall be tested on all load pattern available at site during psot RECD installation. vi. Warranty :- The OEM shall provide Warranty of the in all respect of 01 Year post completion of work/installation. vii. Contractor shall furnish manufacture's written instruction and requirement about the use and maintenence of RECD system, its operation and maintenance schedule.
Supply and fix MS Pipe heavy duty ERW Steel including specials, nominal dia 100 mm for DG set Exhaust fabricated from DG set exhaust to RECD inlet including flange , nut bolts and all other accessories complete all as specified and directed by Engr-In-Charge Note:- The rate are inclusive of fabrication work for installation the device in the exhaut pipe of the DG Set including painting. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor's firm name while carrying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
D G Corporation (BID ID -3101687)
Anil Kumar Sarmah (BID ID -3099091)
M/S Manjit Singh (BID ID -3098641)
M/s. M. G. Babloo Das (BID ID -3100445)
M/S MOHANPASARI (BID ID -3097560)
MD. LATIFUL AHMED HUSSAIN (BID ID -3109976)
AVASANA SOLUTIONS PRIVATE LIMITED (BID ID -3110923)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .