Tender Value
₹56.2 L
EMD Value
₹1.1 L
Closing Date
10 Jan 2024, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Special repair to AC Plants at certain units against BER under GE (I) Navy Jamnagar
2023_MES_630639_1
8707/VAL/E8
Open Tender
Miscellaneous Works
Item Rate
360 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹1,000
GE (I) Navy Jamnagar
₹1.1 L
Yes
14 Jun 2024
1 Dec 2023
12 Jan 2024
1 Dec 2023
10 Jan 2024
29 Dec 2023
Amount
Notes applicable to all items :- (a) All civil work required like masonry wall cut outs and jurry work to pass Pipes, Cables & Ducts at site shall deemed to be included in quoted rates of respective items. Also required PCC foundations for Chillers, Pumps, AHU, Electrical panel board, expansion tank, cooling tower, etc shall deemed to be included in quoted rates of respective items. The cut outs shall be closed and finished to the original finish after completion of work and same is included in the rates. (b) The contractor shall employ his own operators to run the installations round the clock after Phase-I test till successful completion of Phase-II without any extra cost to Government even though the installations have been provisionally taken over by MES.
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets complete all as specified and as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Dismantling of Asbestos cement Corrugated or semi corrugated sheets etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to outside MoD land and depositing where directed complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete all as specified & as directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregate) in columns, pillars, piers, posts, struts and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, canopies, deck slab, shelves and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete1:2:4, type B1 (using 20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
All as per serial item No. 18 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410 W (Gde E-250) quality-A complete all as specified and as directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality 'B’ complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
S&F 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including galvanised iron powder coated (white) snap Grid of size 600x600 mm with main 'T' and cross 'T' having web 25mm, flange 35mm, thickness 0.70mm, wall angle having web/flange 25mm each, 0.70mm thick fixed with soft cleats having web 25mm, flange 25mm and thickness 1.8mm using 4mm dia GI wire and level clip @ 1200mm centre to centre with PVC rawl plug with & including 8mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer's instructions with & including two coats of oil emulsion distemper (OBD) over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of ceiling work including testing on completion as ordered complete all as specified & as directed.
M&L for 2mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified & as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick layer of white cement based wall care putty complete all as specified & as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for preparing newly plastered surface of walls and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 sqm) as per manufacturer's instructions complete all as specified and as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying 3mm thick white cement based wall care putty over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 sqm), as per manufacturer's instructions complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
Cutting/ Chipping/ Dismantling of spall / loose damaged concrete of distressed member in a controlled manner carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete upto good parent concrete to expose the existing reinforcement (direct hammering should be avoided) average thickness of 50-75 mm including cleaning the exposed surfaces by water jet pressure pump at 4 to 5 kg/ Sqcm pressure to remove chlorides and loose particles, air drying the surface etc for further treatment with & including all necessary tools, safety measures like helmet, safety belt, adequate labour insurance, scaffolding, etc. under the supervision of qualified supervisor (the damaged ceiling/ concrete shall only be measured) complete all as specified and as directed.
M&L for applying concrete penetrating, migratory bipolar corrosion inhibitor EPCO KP-100 Krishna Conchem (or equivalent of Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian) conforming to ASTMG-109 by brush/spray with dosage of 4 sqm/litre over the entire chipped off/ exposed concrete area in order to arrest further corrosion of reinforcement bars. The application of EPCO KP-100 shall reduce the corrosion in terms of coulombs by 30% minimum upto migration through the embedded side of concrete as measured by mA all as per the direction of Engineer-in-Charge and all as per manufacturer’s instructions, complete all as specified and as directed.
M&L for providing epoxy bonding material to bonding of old concrete to new concrete by using and applying 25mm average thickness water compatible high strength thritropic ready use mortar (REP-PATCH 45 T of infinite Options or equivalent of Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian) finished even and smooth complete all as per the direction of Engineer-in-Charge and all as per manufacturer’s instructions, complete all as specified and as directed.
Dismantling and taking down of old unserviceable AC plants of capacity 17 TR and 20 TR complete from DFO & 2M DET bldg including ducting, machineries, all types of piping, insulations, Cooling tower, Motor, Pump, AHU, Electric panels and electrical connections with connected accessories including demolition & disposal of PCC foundation etc. including making good of disturbed surfaces and depositing components such as Compressor, Motor, Pump, condenser, cooling tower, etc of AC plant bearing MES number to MES Store Yard of AGE E/M (N) Jamnagar and removing off the balance material from site complete all as directed.
Supply, Installation, Testing and Commissioning of water cooled, floor mounted water chilling plant 8.5TR x 3 Nos (2 Working + 1 Standby) at DFO Bldg complete with sealed Scroll type multiple compressors, VFD starter, Shell & Tube Chiller (DX/ Flooded), Water cooled shell & tube type Condenser, common Base frame/ skid structure, Inter connected Copper Refrigerant piping, Vibration Isolators as per OEM recommendation, Gauge Panel, Flexible connectors at Chiller connections, Automatic Safety Controls, Ozone friendly CFC Free Refrigerant Gas R-407C/ 410A/ Green refrigerant & Oil, Nitrile Rubber Insulation on chiller, offered machine has to be BMS compatible with open protocol and micro-processor based controller with min 7" touch screen display etc to ensure proper functioning of plant to meet the inside design conditions as specified. The Motor shall be suitable for operation on 415 ±10% V, 50 Hz, 3 phase, AC power supply. Chilling machine shall be compatible with its Microprocessor based Control Panel & Starter with main switch. Chiller panel shall be compatible for remote operation & should provide status (additional potential free contacts shall be required to perform this function). Necessary PCC foundation in PCC 1:2:4 (type B1) as recommended by Manufacturer for placement of chillers all as directed complete with & including all components, accessories, connecting wiring, piping etc and covering also the following in the scope of work complete all as specified and directed. Note:- (i) Chilling machine of next higher capacity available with manufacturer shall also be acceptable without any extra cost to the Govt. Description of this item continued upto serial item No. 38.06
Description of serial item No. 38 continued… (ii) Contractor before quoting the tender will visit the site, calculate tonnage, check the design to meet the cooling parameter and feasibility of the installation provided by the department. (iii) Bidder may do his own design to satisfy himself that the design is sufficient to attain the desired parameters. Any shortcomings noticed shall be made good by the contractor without any extra cost to the Department which shall be accounted for in the amount quoted and nothing extra will be payable to the contractor. (iv) Accessories, fittings, supporting items complete as specified in BOQ shall be included in the rate. No extra payment shall be allowed for the same. Chilled Water Leaving Temperature: 7.0 °C Chilled Water Entering Temperature: 12.0 °C Evaporator Fouling factor: 0.0001 (sqft Hr-F)/Btu Chilled Water Circulation Rate: 2.086 L/s Max Fluid Pressure Drop: 11.7 Kpa Suitable for Refrigerant: R410a/ Green gas Condenser Water Leaving Temperature: 36 °C Condenser Water Entering Temperature: 32 °C Condenser Fouling factor: 0.00025 (sqft Hr-F)/Btu Condenser Water Circulation Rate: 3.230 L/s Max Fluid Pressure Drop: 26.4 Kpa IKW/ TR at design conditions = equal or less than 0.8347 KW/TR NPLV at design conditions = equal or less than 0.4753 KW/TR COP at AHRI conditions = equal or more than 4.4 KW/KW IPLV at AHRI conditions = equal or more than 0.4881 KW/TR Makes:- Blue Star Model XWC2VS-013AR3 / Carrier / Voltas / Daikin / Hitachi
Description of serial item No. 38 continued… The Motor shall be suitable for operation on 415 ±10% V, 50 Hz, 3 phase AC power supply. Chilling machine shall be complete with its Microprocessor based Control Panel & Starter with main switch. Chiller panel shall be compatible for remote operation & should provide status (additional potential free contacts shall be required to perform this function). Necessary PCC foundation in PCC 1:2:4 (type B1) as recommended by Manufacturer for placement of chillers all as specified & directed covered in the scope of work. Supply, install, testing and commissioning FRP included draft cooling tower (01 No.) rectangular/ cylindrical type complete with FRP basin capacity suitable for 25 TR (minimum) all as required for water cooled chilling machine 25 TR capacity complete installed on PCC/ brick masonry staging with spray section, honey comb fill basin, MS girders, Ladder, statically & dynamically balanced axial flow fan direct driven or driven through reduction gear box with suitable capacity of induction TESC Motor working on 415 V +/- 10%, 3 phase, 50 Hz AC supply, intake, make up quick filling arrangement, bird screen necessary valves for intake, drain & overflow and other accessories all as recommended by OEM. Note:- The rates quoted deemed to be inclusive of excavation, RFR, earth works and suitable PCC/ RCC foundation (for cooling tower) as per OEM design all as specified & directed and connected piping with stop cock from make up water tank to cooling tower including all the miscellaneous items required for satisfactory completion of the job.
Description of serial item No. 38 continued… Supply and fixing 25mm thick Double Skin type Air Handling Unit (01 No.) 10000 CFM capacity with 10 Micron Pre filters 6 row deep coil with starter Panel with following description :- (a) Double skinned type horizontal floor mounted, top/ side discharge air handling unit with double skin Hollow aluminium profile construction using 22 G sheet metal sandwitch panels with 43mm thick injected spray type PUF panels, density 38 Kg/Cum. (b) Fan section with AMCA Certified backward curved type Blower with outlet velocity not exceeding 9.2 m/sec . (c) 18 Gauge MS CRCA duly powder coated AHU Sub Panel board in compartmentalized construction with Incomer and Outdoing feeders for AHU Motor etc. (d) Accessories like Hinges type Access doors for Filter section, Fan section etc., Sight glass, Marine Lamp with limit switch, Supply, Return and Fresh Air flanged type connections with low leakage air foil design Dampers, Rubber sleeves for Pipe & Cable entry, Flow direction arrows, Vibration isolation spring type pads, Motor sliding Rail etc. Static pressure (mm) -80 with 10 micon pre-filters. Make of AHU:- Blue Star/ National/ Zeco/ Voltas/ Daikin/ Hitachi/ O-General
Description of serial item No. 38 continued… CHILLED WATER PUMPSETS - HORIZONTAL BACK PULL OUT TYPE WITH INSULATION: Supply, installation, testing and commissioning of end suction & top discharge type centrifugal pumps (03 Nos) back pull out type for chilled water recirculation complete, with cast iron body, bronze impeller complete with mechanical seals, TESC squirrel cage high efficiency induction motor, base plate, mounting channel frame, accessories and fittings i.e. flexible connectors (bellows) at inlet & outlet connections, mechanical seal, pressure gauges, thermometers, drains, couplings, guard, vibration isolation arrangement by means of Resistoflex make as specified of the following capacities and shall be suitable for operation on 415 +/- 10% volts 50Hz, 3 Phase AC Supply. The pumps shall be insulated with Nitrile Rubber with suitable thickness including necessary foundation as recommended by manufacturer. (a) Capacity: - Discharge minimum 35 USGPM or as recommended by the manufacturer of chilling unit. (b) Head: - 20 Mtr ( Contractor to check and verify the pump head as per site requirement). (c) Impeller: - Bronze (d) Electric Motor capacity: - As recommended by the manufacturer of pump (e) Make of Pump :- Beacon/ Kirloskar/ CRI/ Crompton/ KSB/ Wilo Mather/ Jyoti/ V Guard (f) Make of Motor :- Crompton/ Kirloskar/ Siemens/ ABB/ NGEF/ Bharat Bijlee
Description of serial item No. 38 continued… (g) Necessary civil work such as PCC foundation in PCC 1:2:4 (type B1) etc as recommended by manufacturer for placement of pump sets all as specified & directed deemed to be included in quoted rate. CONDENSED WATER PUMPSETS - HORIZONTAL BACK PULL OUT TYPE WITH INSULATION: Supply, installation, testing and commissioning of end suction & top discharge type centrifugal pumps (03 Nos) back pull out type for condensed water recirculation complete, with cast iron body, bronze impeller complete with mechanical seals, TESC squirrel cage high efficiency induction motor, base plate, mounting channel frame, accessories and fittings i.e. flexible connectors (bellows) at inlet & outlet connections, mechanical seal, pressure gauges, thermometers, drains, couplings, guard, vibration isolation arrangement by means of Resistoflex make as specified of the following capacities and shall be suitable for operation on 415 +/- 10% volts 50Hz, 3 Phase AC Supply. The pumps shall be insulated with Nitrile Rubber with suitable thickness including necessary foundation as recommended by manufacturer. (a) Capacity: - Discharge minimum 55 USGPM or as recommended by the manufacturer of chilling unit. RPM - 2900 (b) Head: - 18 Mtr (Contractor to check and verify the pump head as per site requirement). (c) Impeller: - Bronze (d) Electric Motor capacity: - As recommended by the manufacturer of pump
Description of serial item No. 38 continued… (e) Make of Pump : - Beacon/ Kirloskar/ CRI/ Crompton/ KSB/ Wilo Mather/ Jyoti/ V Guard (f) Make of Motor :- Crompton/ Kirloskar/ Siemens/ ABB/ NGEF/ Bharat Bijlee (g) Necessary civil work such as PCC foundation in PCC 1:2:4 (type B1) etc as recommended by manufacturer for placement of pump sets all as specified & directed deemed to be included in quoted rate. Notes :- (a) All civil works for PCC Foundation, etc as per recommendation of manufacturer required for installation of AC plant, etc shall deemed to be included in the rate quoted against the item. No extra payment shall be made on this account. (b) Unit rate quoted by the contractor deemed to be included for the followings:- (i) Submission of floor Drgs & details, Lay out plan for equipments etc for approval of Accepting Officer. (ii) Providing all minor parts which are not included in brief specification but required technically at site for Installation, commissioning, testing of entire plant to achieve designed condition & efficient performance, smooth functioning of the plant. (iii) PCC works for foundation as per manufacturer instruction, plastering, Earth works (iv) submission of catalogues for major equipments. (v) Internal wiring for auto function and safety measures of equipments. (vi) Arrangement for providing testing instruments and artificial load if required for Phase-I & II testing.
Supply, Installation, Testing and Commissioning of water cooled, floor mounted water chilling plant 10 TR x 3 Nos (2 Working + 1 Standby) at 2M DET Bldg complete with sealed Scroll type multiple compressors, VFD starter, Shell & Tube Chiller (DX/ Flooded), Water cooled shell & tube type Condenser, common Base frame/ skid structure, Inter connected Copper Refrigerant piping, Vibration Isolators as per OEM recommendation, Gauge Panel, Flexible connectors at Chiller connections, Automatic Safety Controls, Ozone friendly CFC Free Refrigerant Gas R-407C/ 410A/ Green refrigerant & Oil, Nitrile Rubber Insulation on chiller, offered machine has to be BMS compatible with open protocol and microprocessor based controller with min 7" touch screen display etc to ensure proper functioning of plant to meet the inside design conditions as specified. The Motor shall be suitable for operation on 415 ±10% V, 50 Hz, 3 phase AC power supply. Chilling machine shall be complete with its Microprocessor based Control Panel & Starter with main switch. Chiller panel shall be compatible for remote operation & should provide status (additional potential free contacts shall be required to perform this function). Necessary PCC foundation in PCC 1:2:4 (type B1) as recommended by Manufacturer for placement of chillers, all as specified & directed covered in the scope of work. Note:- (i) Chilling machine of next higher capacity available with manufacturer shall also be acceptable without any extra cost to the Govt. Description of this item continued upto serial item No. 39.06
Description of serial item No. 39 continued… (ii) Contractor before quoting the tender will visit the site, calculate tonnage, check the design to meet the cooling parameter and feasibility of the installation provided by the department. (iii) Bidder may do his own design to satisfy himself that the design is sufficient to attain the desired parameters. Any shortcomings noticed shall be made good by the contractor without any extra cost to the Department which shall be accounted for in the amount quoted and nothing extra will be payable to the contractor. (iv) Accessories, fittings, supporting items complete as specified in BOQ shall be included in the rate. No extra payment shall be allowed for the same. Chilled Water Leaving Temperature: 7.0 °C Chilled Water Entering Temperature: 12.0 °C Evaporator Fouling factor: 0.0001 (sqft Hr-F)/Btu Chilled Water Circulation Rate: 2.086 L/s Max Fluid Pressure Drop: 11.7 Kpa Suitable for Refrigerant: R410a/ Green gas Condenser Water Leaving Temperature: 36 °C Condenser Water Entering Temperature: 32 °C Condenser Fouling factor: 0.00025 (sqft Hr-F)/ Btu Condenser Water Circulation Rate: 3.230 L/s Max Fluid Pressure Drop: 26.4 Kpa IKW/TR at design conditions = equal or less than 0.8347 KW/TR NPLV at design conditions = equal or less than 0.4753 KW/TR COP at AHRI conditions = equal or more than 4.4 KW/KW IPLV at AHRI conditions = equal or more than 0.4881 KW/TR
Description of serial item No. 39 continued… Makes:- Blue Star Model XWC2VS-013AR3 / Carrier / Voltas / Daikin / Hitachi The Motor shall be suitable for operation on 415 ±10% V, 50 Hz, 3 phase AC power supply. Chilling machine shall be complete with its Microprocessor based Control Panel & Starter with main switch. Chiller panel shall be compatible for remote operation & should provide status (additional potential free contacts shall be required to perform this function). Necessary PCC foundation in PCC 1:2:4 (type B1) as recommended by Manufacturer for placement of chillers all as specified & directed covered in the scope of work. Supply, install, testing and commissioning FRP included draft cooling tower (01 No.) rectangular/ cylindrical type complete with FRP basin capacity suitable for 25 TR (minimum) all as required for water cooled chilling machine 25 TR capacity complete installed on PCC/ brick masonry staging with spray section, honey comb fill basin, MS girders, Ladder, statically & dynamically balanced axial flow fan direct driven or driven through reduction gear box with suitable capacity of induction TESC Motor working on 415 V +/- 10%, 3 phase, 50 Hz, AC supply, intake, make up quick filling arrangement, bird screen necessary valves for intake, drain & overflow and other accessories all as recommended by OEM. Note:- The rates quoted deemed to be inclusive of excavation, RFR, earth works and suitable PCC/ RCC foundation (for cooling tower) as per OEM design all as specified & directed & connected piping with stop cock from make up water tank to cooling tower including all the miscellaneous items required for satisfactory completion of the job.
Description of serial item No. 39 continued… Supply and fixing 25mm thick Double Skin type Air Handling Unit (01 No.) 11000 CFM capacity with 10 Micron Pre filters 6 row deep coil with starter Panel with following description:- (a) Double skinned type horizontal floor mounted, top/ side discharge air handling unit with double skin Hollow aluminium profile construction using 22 G sheet metal sandwitch panels with 43mm thick injected spray type PUF panels, density 38 Kg/Cum. (b) Fan section with AMCA Certified backward curved type Blower with outlet velocity not exceeding 9.2 m/sec . (c) 18 Gauge MS CRCA duly powder coated AHU Sub Panel board in compartmentalized construction with Incomer and Outdoing feeders for AHU Motor etc. (d) Accessories like Hinges type Access doors for Filter section, Fan section etc., Sight glass, Marine Lamp with limit switch, Supply, Return and Fresh Air flanged type connections with low leakage air foil design Dampers, Rubber sleeves for Pipe & Cable entry, Flow direction arrows, Vibration isolation spring type pads, Motor sliding Rail etc. Static pressure (mm) -80 with 10 micon pre-filters. Make of AHU: - Blue Star/ National/ Zeco/ Voltas/ Daikin/ Hitachi/ O-General
Description of serial item No. 39 continued… CHILLED WATER PUMPSETS - HORIZONTAL BACK PULL OUT TYPE WITH INSULATION: Supply, installation, testing and commissioning of end suction & top discharge type centrifugal pumps (03 Nos) back pull out type for chilled water recirculation complete, with cast iron body, bronze impeller complete with mechanical seals, TESC squirrel cage high efficiency induction motor, base plate, mounting channel frame, accessories and fittings i.e. flexible connectors (bellows) at inlet & outlet connections, mechanical seal, pressure gauges, thermometers, drains, couplings, guard, vibration isolation arrangement by means of Resistoflex make as specified of the following capacities and shall be suitable for operation on 415 +/- 10% volts 50Hz, 3 Phase AC Supply. The pumps shall be insulated with Nitrile Rubber with suitable thickness including necessary foundation as recommended by manufacturer. (a) Capacity: - Discharge minimum 35 USGPM or as recommended by the manufacturer of chilling unit. (b) Head: - 20 Mtr (Contractor to check and verify the pump head as per site requirement). (c) Impeller: - Bronze (d) Electric Motor capacity: - As recommended by the manufacturer of pump (e) Make of Pump:- Beacon/ Kirloskar/ CRI/ Crompton/ KSB/ Wilo Mather/ Jyoti/ V Guard (f) Make of Motor: - Crompton/ Kirloskar/ Siemens/ ABB/ NGEF/ Bharat Bijlee
Description of serial item No. 39 continued… (g) Necessary civil work such as PCC foundation in PCC 1:2:4 (type B1) etc as recommended by manufacturer for placement of pump sets all as specified & directed deemed to be included in quoted rate. CONDENSED WATER PUMPSETS - HORIZONTAL BACK PULL OUT TYPE WITH INSULATION : Supply, installation, testing and commissioning of end suction & top discharge type centrifugal pumps (03 Nos) back pull out type for condensed water recirculation complete, with cast iron body, bronze impeller complete with mechanical seals, TESC squirrel cage high efficiency induction motor, base plate, mounting channel frame, accessories and fittings i.e. flexible connectors (bellows) at inlet & outlet connections, mechanical seal, pressure gauges, thermometers, drains, couplings, guard, vibration isolation arrangement by means of Resistoflex make as specified of the following capacities and shall be suitable for operation on 415 +/- 10% volts 50Hz, 3 Phase AC Supply. The pumps shall be insulated with Nitrile Rubber with suitable thickness including necessary foundation as recommended by manufacturer. (a) Capacity: - Discharge minimum 55 USGPM or as recommended by the manufacturer of chilling unit. RPM - 2900 (b) Head: - 18 Mtr (Contractor to check and verify the pump head as per site requirement). (c) Impeller: - Bronze (d) Electric Motor capacity: - As recommended by the manufacturer of pump
Description of serial item No. 39 continued… (e) Make of Pump:- Beacon/ Kirloskar/ CRI/ Crompton/ KSB/ Wilo Mather/ Jyoti/ V Guard (f) Make of Motor :- Crompton/ Kirloskar/ Siemens/ ABB/ NGEF/ Bharat Bijlee (g) Necessary civil work such as PCC foundation in PCC 1:2:4 (type B1) etc as recommended by manufacturer for placement of pump sets all as specified & directed deemed to be included in quoted rate. Notes :- (a) All civil works for PCC Foundation, etc as per recommendation of manufacturer required for installation of AC plant, etc shall deemed to be included in the rate quoted against the item. No extra payment shall be made on this account. (b) Unit rate quoted by the contractor deemed to be included for the followings:- (i) Submission of floor Drgs & details, Lay out plan for equipments etc for approval of Accepting Officer. (ii) Providing all minor parts which are not included in brief specification but required technically at site for Installation, commissioning, testing of entire plant to achieve designed condition & efficient performance, smooth functioning of the plant. (iii) PCC works for foundation as per manufacturer instruction, plastering, Earth works (iv) submission of catalogues for major equipments. (v) Internal wiring for auto function and safety measures of equipments. (vi) Arrangement for providing testing instruments and artificial load if required for Phase-I & II testing.
Supply, installation, testing & commissioning of Mild Steel Chilled Water Piping 50mm bore of Class 'C', Heavy duty confirming to IS: 1239 (Part-1) 1991 & IS: 3589-1991 Grade 330 cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports, air purge valves, drain valves etc. complete all as specified & as directed. Make: TATA/ JINDAL/ ZENITH/ SURYA PRAKASH
All same as per serial item No. 40 here-in-above, but MS Chilled Water piping of 65mm bore.
All same as per serial item No. 40 here-in-above, but MS Chilled Water piping of 80mm bore.
All same as per serial item No. 40 here-in-above, but MS Chilled Water piping of 100mm bore.
M&L for insulation for MS pipe 50 mm bore with thermocol Pipe section 30mm thick with and including applying bituminous compound and aluminium cladding complete all as specified and as directed.
All same as per serial item No. 44 here-in-above, but for MS pipe 65 mm bore.
All same as per serial item No. 44 here-in-above, but for MS pipe 80 mm bore.
All same as per serial item No. 44 here-in-above, but for MS pipe 100 mm bore.
Supply, installation, testing and commissioning of PN 16 Butterfly valves of 50 mm dia duly insulated with companion flanges, nuts, bolts, gaskets etc. as specified. Butterfly valves with cast iron body. The valves shall be suitable for flow in either direction and seal in both directions. The valves shall be of integral moulded design.
All same as per serial item No. 48 here-in-above, but 65 mm dia.
All same as per serial item No. 48 here-in-above, but 80 mm dia.
S&F Balancing Valve 50mm dia for Chilling plant of suitable sizes and specification and as specified & as directed.
S&F Balancing Valve 65/ 80mm dia of suitable sizes and specification and as specified & as directed.
Blank
Supply, installation, testing & commissioning of Y-Type Strainer C.I / MS body 50 mm dia for Pump, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh 24G X 14 mesh for chilled water application complete with flanges, nuts-bolts, gaskets duly insulated with 50mm thick TF Quality all as specified & directed. Make:- TRISHUL/ LEADER/ SANT/ FLOWEL/ HONEYWELL/ RAPID COOL
All same as per serial item No. 54 here-in-above, but 65 mm dia.
Supply, installation, testing and commissioning of Wafer Swing Check type Non- Return Valve 50mm dia, PN -16 rating with cast iron body, flanges, gaskets etc with insulation all as specified & directed.
All same as per serial item No. 56 here-in-above, but 65 mm dia.
Supply, installation, testing & commissioning of PN 1.6, 3-way modulating valves 65-100 mm dia for AHU's chilled water coil application complete with motor actuator, thermostat, voltage transformer, flanges, nuts-bolts, gaskets duly insulated with 50mm thick TF Quality as specified and required all as specified & as directed. Make:- Honeywell/ Rapid control/ Anergy
Supply, installation, testing & commissioning of 100mm dial type Pressure Gauge with appropriate range & valves and SS tubing all as specified & as directed.
Supply, installation, testing & commissioning in length 100mm dial type Temp Gauge with appropriate range & SS valves and SS tubing all as specified & as directed. Make: Honeywell/ Rapid control/ Flebig/ H-Guru
Supply and fixing in position 25mm flow switch complete with copper conductor control wiring at chiller outlet of each machine confirming to IS 3589 of 6 mm thick duly tested all as specified & as directed. Make:- H GURU, FIBIEG, HONEYWELL, ANERGY
Supply, installation, testing & commissioning of 15/ 25mm dia Auto Air Purge valve for chilled water piping all as specified & as directed. Make:- Castle/ Anergy/ Honeywell
Supply, assembly, and erecting of 20 gauge GI sheet with TDF Flange rectangular/ square duct made out of L shaped hollow profile duly factory boxed, inclusive of all accessories such as corner, cleat, carriage bolt, nuts, washer, threaded hanging rods, Gasket and appropriate sealant on longitudinal joints etc. complete all as specified & as directed.
All same as per serial item No. 63 here-in-above, but using galvanised steel sheet of 22 gauge galvanized sheet.
All same as per serial item No. 63 here-in-above, but using galvanised steel sheet of 24 gauge galvanized sheet.
S&F Duct insulation 12-15 mm thick with nitrile rubber insulation complete all as specified & as directed.
Supply and installation of Acoustic insulation with using 12-15mm thick open cell Nitrile Rubber to reduce the noise level in duct/ plenum all as directed.
M&L for under deck insulation with Thermocol slab of 60mm thick including application of cold bitumen on thermocol slab, GI wire of size 28 gauge fixed with RCC roof by means of MS screws, washers etc for fastening of thermocol slab, suitable for the thermocol slab to be pasted on RCC roof slab complete all as specified & as directed.
Supply, installation, testing and commissioning of automatic Fire damper of Fusible Link type as required for operation complete all as specified & as directed. Note: The fire dampers shall be spring activated on melting of fusible link having melting point of 67° to 68° C. Fire damper shall be tested as per ULL-555 and certified by CBRI all as directed.
Supply, install and commissioning GI 16 gauge volume control damper of suitable sizes all as specified and as directed.
S&F Supply/Return air Diffusers/ Grills of extruded Aluminium sections duly powder coated with black volume control Damper all as specified and as directed.
S&F MS Support/ Structure for Pipe Support/ Duct support/ chilled & cable tray suitable for the UG cables required for the satisfactory completion of job and column fabricated with MS sections and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :- (i) Size, section and shape of MS Support/ Structure shall be as directed. (ii) Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
Supply and fixing rigid PVC Expansion tank of 500 Ltrs capacity for chilled water line, Double layer duly insulated with 50mm thick EPS (Expanded Polystyrene) slab covered with vapour barrier, GI chicken wire mesh and finished with sand cement plaster with inlet, outlet, drain and over flow connections with all valves as specified and as directed.
Supply and fixing rigid PVC Rotational moulded polyethylene water storage tank/ Make up water tank 2000 Ltrs Capacity, triple layer complete all as specified and as directed.
Supply and installation of Electrical Strip Heater, finned type, capacity 3 kW consisting of stainless steel sheathing having heat resistant chrome-nickel 80/20 element protected under best insulation to avoid the leakage of current and with screwed type terminal at one end, 240 volts, AC, 50Hz, single phase complete with heater plenum for humidity control with Humidistat/ Thermostat & safety thermostat with all necessary electric cabling complete all as specified and as directed. Make: - Industrial/ Rapidcool/ Daspass
Supplying, installation, testing and commissioning of Humidifier Pan type 9 KW rating, complete with all accessories of reputed make all as specified and as directed.
Supply, installation, testing and commissioning of floor mounted, indoor duty, cubicle & compartmentalized, front access type, medium voltage electric panel of dust and vermin proof, fully tropicalised construction, front openable doors and shutters with locking arrangement, made out of 2.0mm thick CRCA sheet steel, factory fabricated, powder coated, suitable for operation on 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply complete with all interconnections and consisting of all accessories like Aluminium Bus Bar of capacity 600 Amps, LED Type Indicating lamps, Push buttons, CTs, Digital Ampere, Voltage, Frequency & KWH meter, Danger Plate, Lifting Hooks, Feeder Name Plates suitable for the following feeders (Note: - The Panel shall be of suitable size to accommodate all the accessories mentioned below, installed on Pedestal made out of angle iron of size 50mm x 50mm x 6mm & earth work, PCC foundation, 1:2:4 (type B1) suitable cable glands for cable entry etc.), comprising & including the following accessories complete all as specified and as directed :- Description of this item continued.....
Description of serial item No. 77 continued… (a) MCCB 400 Amps TPN 415 volts micro thermal based with inter rupturing breaking capacity 36 kA - 01 No. (Incoming) (b) MCCB 160 Amps TPN micro thermal based with inter rupturing breaking capacity 25 kA - 02 Nos (For 02 Nos Compressor) (c) MCCB 100 Amps TPN micro thermal based with inter rupturing breaking capacity 25 kA - 01 No. (For 01 No. AHU) (d) MCCB 63 Amps TPN micro thermal based with inter rupturing breaking capacity 16 kA - 04 Nos (For Chiller & Condenser motor) (e) MCB TP 32 Amps - 01 No. (For CT Fan of cooling tower) (f) Suitable Star Delta Starter - 03 Nos. (For Condenser Pump) (g) Suitable Star Delta Starter - 03 Nos. (For Chiller Pump) (h) Star Delta Starter suitable for 10 HP - 01 No. (For 01 No AHU) (j) DOL starter suitable for 3 HP CT Fan motor - 01 No (For Cooling Tower)
Description of serial item No. 77 continued… Notes : (i) LT cubical panel shall be manufactured from CPRI approved manufacturer's/ Firm as approved by GE. (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
S&F GI slotted cable tray made out of 16 Gauge and 150x75mm width including necessary supports and frame work all as specified.
M&L for 4 Core, 16 Sqmm XLPE insulated copper conductor armoured cables of 1100 volt grade, Including cost of all crimping lugs and single compression glands, cable sockets insulation tape, sealing compound etc all as directed.
M&L for 4 Core, 10 Sqmm XLPE insulated copper conductor armoured cables of 1100 volt grade, Including cost of all crimping lugs and single compression glands, cable sockets insulation tape, sealing compound etc all as directed.
Supply & Laying of 2 Core, 1.5 Sqmm XLPE insulated copper conductor armoured cables for control all as specified & as directed.
Supply & Laying of 3 Core, 1.5 Sqmm XLPE insulated copper conductor armoured cables for control all as specified & as directed.
Supply and fix earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5m deep below normal ground connected to galvanised mild steel strip 32x6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20mm bore galvanised iron medium grade and 40mm bore galvanised iron light grade from earth plate to testing point for earth strip protection upto 7.5 mtr length including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg/ sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No. 3 of SSR Part-I and testing on completion. Note: - Earthing to be connected in grid connection in common bus bar pattern and independent earth test point to be provided. Quoted rates shall be deemed to include for earth test point, earth strip with protection pipe up to 7.5 M length.
Supply and fix aluminium strips of size 32 x 6mm (for grid connection) all as specified and as directed.
Supply and fix GI strips of size 32 x 6mm (for grid connection) all as specified and as directed.
S&F 15 - 25mm dia Ball type Drain valve for chilled & Cooling water piping.
M&L for 25mm bore GI pipe medium grade with all fittings fixed complete to walls, ceilings or laid in floors all as specified and as directed.
M&L for 15 mm bore GI pipe medium grade with all fittings fixed complete to walls, ceilings or laid in floors all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm, 3.5 core complete all as specified and as directed.
shivrefrigeration
BRITE INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .