| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC ANAND VIHAR COLONY WARD NO 01 FULUNGA RUDRAPUR DISTT UDHAMSINGH NAGAR PIN 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | L1 | Accepted-AOC Being L1 Firm | |
| 2 | L2₹5.9 L+₹28,227.50 (5.00%)Rejected-Finance JUNIOR A 3 CIVIL LINES MAKKA MILL RAMPUR UP PIN 240901 | 240901 | L2 | Rejected-Finance Being L2 |
Tender Value
₹6.0 L
EMD Value
₹11,990
Closing Date
26 May 2025, 10:30 amClosed
Assistant Commandant (Engineer)
O/o THE DIG, GROUP CENTRE CRPF, RAMPUR (U.P) PIN-244901
Repair, Maintenance of all damaged Electric Cable Faults, Electric Panels and Various Type of Fans/Lights and MCCB/Switch-Socket Boxes at GC CRPF Kathgodam
2025_CRPF_860715_1
B.V(GC Kathgodam)/2025-25-Minor Works(NIT-3)
Open Tender
Electrical Works
Item Rate
30 days
GC CRPF Kathgodam
As per Tender Documents
16 documents required · 16 mandatory
₹0
₹11,990
11 Jun 2025
20 May 2025
27 May 2025
20 May 2025
26 May 2025
20 May 2025
Amount
Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work
Troubleshooting and find fault in under ground cables with the help of Fault Detection Machine, excation of soil and reflling, etc, as required. First Fault
Troubleshooting and find fault in under ground cables with the help of Fault Detection Machine, excation of soil and reflling, etc, as required. Other faults after detection of First Fault
Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required.3x1/2 X 35 Sq.mm (3.5 Core)
Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required.3x1/2 X 70 Sq.mm (3.5 Core)
Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required. 3x1/2 X 95 Sq.mm (3.5 Core)
Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required. 3x1/2 X 240 Sq.mm (3.5 Core)
Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required. 4x16 Sqmm (4 core)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Fabrication, installation, testing and commisioning of busbar box 200 AMP outdoor type stand mount for providing a new connection of DG for 300 KLD STP complete with relays, set of CTs of metering & restricted earth fault and elsewhere if require all complete and locking including and control cable for interconnections with AMF panel. and the following: Busbar box 200A AMP outdoor type stand mount (650 X 1600 X 450 Sqmm) (1 Nos), LUG 120 Sqmm (10 Nos), LUG 70 Sqmm (10 Nos), PBC TAP (6 Nos), Fastner clip (8 Nos), Installation charges (1 Nos) including total cost of normal busbar panel
Rewiring of damaged ceiling fans, overhauling, repairing, capacitor, replacement of bearing, mechanical seal etc complete as required
Rewiring of damaged exhuast fans, overhauling, repairing, capacitor, replacement of bearing, mechanical seal etc complete as required
Supplying and laying of following size XPLE insulated, armoured, power cable of 1.1 KV grade, duly ISI marked, with Aluminium conductor, confirming to IS: 7098 (Part-I) in existing RCC / HUME / GI / DWC HDPE pipe, as required. 4 X 16 Sq.mm (4 core)
Supplying and laying of following size XPLE insulated, armoured, power cable of 1.1 KV grade, duly ISI marked, with Aluminium conductor, confirming to IS: 7098 (Part-I) in existing RCC / HUME / GI / DWC HDPE pipe, as required. 2 X 25 Sqmm ( 2 core)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupler, etc, confirming to IS 14930, part-II complete with fitting and cutting, jointing, etc. direct in ground (75 cm brlow from ground level) including excavation and refilling trench but excluding sand crushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm Nominal)
Repalcement of faulty door & cover plate of steel sheet 8 way TPN&DB panel box with puss botton /locking arrangement & sprind system i/c powder printed, earthing etc complete as required.
Providing & replacement of 3 phase digital meter display i.e. Voltmeter / Ammeter complete as required
Providing & replacement of analog 24 hours timer (GIC make) of existing electric fidder panel of street lights complete as required by Engineering Incharge.
Providing & replacement of RYB indication 240 volts (Make Estter) of existing electric fidder panel of complete as required by Engineering Incharge.
Providing & replacement of nornal panel lock with a key of existing electric fidder panel of street light & electric meter complete as required by Engineering Incharge.
Providing & replacement of PTMT plated 125/150 mm mortice latch and lock with a moving lever handle of existing electric fidder panel complete as required by Engineering Incharge.
Providing & replacement of 40A DP ELCB 300 MA of existing DB panels of ADM block complete as required by Engineering Incharge.
Providing & replacement of Power contractor 4 Pole 160 A MCX-22 4 of existing main panel of T-V & IV quarters complete as required by Engineering Incharge.
Providing & Rewiring (i/c removing of existing damaged copper wire) of various elements/ light points of fire alarm system (element : Smoke deductor, heet deductor, hooter, MCP, response indicator, fire panel) with help of 1 Sqmm 2 core copper flexible sealed conductor wire etc complete as required.
Repairing and servicing of LT line outdoor type fedder panel of street light system etc i/c rewiring, replacement of thimbles (i/c connector & MCB channel), insulation of bus bars etc complete as required without replacement of switch gears.
Providing & installation 125A manual on load changeover switch (Make L&T & HPL) to connect with DG in 02 pump houses etc complete as required by Engineer Incharge.
MAHI TRADERS (BID ID -3220100)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .