Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | ₹44.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹45.6 L+₹89,670 (2.01%)Rejected-AOC | ₹45.6 L+₹89,670 (2.01%) | L2 | Rejected-AOC L2 |
| 3 | L3₹45.6 L+₹91,782 (2.05%)Rejected-AOC | ₹45.6 L+₹91,782 (2.05%) | L3 | Rejected-AOC L3 |
| 4 | L4₹47.7 L+₹3.0 L (6.63%)Rejected-AOC | ₹47.7 L+₹3.0 L (6.63%) | L4 | Rejected-AOC L4 |
| 5 | L5₹51.9 L+₹7.2 L (16.1%)Rejected-AOC | ₹51.9 L+₹7.2 L (16.1%) | L5 | Rejected-AOC L5 |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
12 Feb 2022, 6:00 pmClosed
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
Provision of Galvalume sheet chajjas, Addn/Altn to wooden flooring, Addn/Altn to lawn stage, Provn of tiling and Provn of pathway at MAP qtrs SMQs, Officer Mess, 14 AFH and OMQ area at AFA Hyd.
2021_MES_498684_1
8202/E8
Open Tender
Civil Works
Item Rate
GE (AFA) Hyderabad
As per tender docuements
4 documents required · 4 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹85,000
Yes
19 Mar 2022
31 Dec 2021
14 Feb 2022
31 Dec 2021
12 Feb 2022
15 Jan 2022
31 Dec 2021 - 14 Jan 2022
Amount
Cutting chases, pinning in brick or concrete wall surfaces and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of sunshades, lintels, chajjas etc at any height, cutting not exc 10 cm girth etc complete all as specified and as directed.
S&F for Mild Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I S.1161-1979 grade St.-240 for fixing roof covering or sheets etc at any height, conforming to Fe 410-W (Gde E-250) quality A, etc complete all as specified and as directed.
S&F for Mild steel plates, plain 5mm thick or over in thickness including fixing with Anchorage Bolt to the walls at any height, confirming to Fe-410-W(Gde- E-250) quality-A etc complete all as specified and as directed.
S&F for Mild steel screw Anchorage bolts 11 to 15mm dia (machine made) with hexagonal or square heads at one end to be fitted, exc 5cm but n exc 10cm long etc all as specified and as directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (curved on front side) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall at any height, fixed with self tapping screws etc complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of redoxide zinc crome primer for surfaces of any description, over 10cm in width or girth, not otherwise described, complete all as specified and as directed
Dismantling of Floor board of any description fixed in any position, complete all as specified and as directed.
Dismantling of Timber scantlings in fillets,rails, posts, rafters, purlins etc under 40 Sqcm in section in framed work, fixed in any position, complete all as specified and as directed.
M & L 50 mm thick cement concrete(1:2:4) type B-1, using 20 mm graded stone aggregate) as in flooring, including finishing surfaces even & smooth w/o using extra cement complete all as specified and directed.
M & L for Wooden sports Flooring, Maple Wood Engineered floorboard finished with 21 mm thick, 45 to 70 mm width and in random length in tongue and groove shape, the edges of the boards will have a finger lock groove and the bottom side with air pass groove and applied with polyurethane lacquer and laid staggered pattern along the length of coart (Perpendicular to the runners) and fixed to the under frame is made of commercial quality Fir / Spruce / Pine wood runner of 70 mm x 45 mm by concealed screws loose tongues, to be inserted, the S.P.F. runners should be kiln dried chemically treated of moisture content not more than 10% to 12%, provided at a distance of 300 mm centre to centre and mounted on Aircush rubber cushion pads of 10 to 19 mm thick, 50 mm x 70 mm with two wings at 300 mm. having 20 circular cavities and 30 circular cavities on each sides (The over all height of floor above the concrete sub floor is not to exceed 80 mm) , etc complete all as specified and as directed. Make: Royal Sports Florring or equivalent approved by GE
(a) A vapor barrier of 6 ml. (600 micron) thick will be placed on the leveled IPS sub-floor before laying the under frame.
(b) The runners having air cell cushioning pads 10 to 19 mm thick will be placed on the vapor barrier in perfect level at 300 mm c/c in one direction. The surface boards will be screwed to the runners through the tongue only and will lock the screwed tongue by the groove of the adjioning boards. The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive.
(c) All Engineered floor boards and S.P.F. runners are to be Pre-dipped with Anti-termite and under side of floor boards coated with polyurethane.
(d) An expansion gap of 8 to 10 mm will be left open the wooden flooring and surrounding tiled area / wall.
( e) No joint of length of adjoining are to be next to each other.
(f) After Installation the floor will be machine sanded in uniform level and finished with imported non-skid and sweet proof DIN certified Bona-Tech Polyurethane lacquer. Game line marking will be carried out in required colors before applying the finish area.
(g) All playing area court marking are to be done as per specification of WSF.
(h) Certificate to be provided by the OTTO GRAF INSTITUTE, GERMANY or any other approved authority that the lacquer meets the friction properly as per DIN STANDARD.
M&L for Removing the existing plaster, supply and application of Cement based Hard Plaster system conforming the requirement of WSF (World Squash Federation) consisting of a Base Coat and a Finish Coat of a total thickness of app. 15 mm and coated with imported washable paint system. The hard plaster shall be provided all as specified herein below :-Make: Royal Sports Florring or equivalent approved by GE
(a) Applying one coat of hard plaster base coat approx 8 to 12 mm thick on the brick wall as per manufacturer's instruction.
(b) Applying one coat of hard plaster base coat approx 8 to 12mm thick on the brick wall as per manufacturer's instruction and cured for minimum period of 21 days
( c) A coat of bonder paint systems.
(d) Three coats of washable paint systems.
M&L for Painting and game line marking on walls of Squash court as per World Squash Federation specification all as specified and directed.
M&L for Sound Board System with fittings with descriptions: 2.14m x 0.43m x 3nos, Tin Court Board 22gauge, etc all as specified and directed.
Demolition of Plain cement concrete and tiles of any description and in any position not otherwise specifically provided for, and removing the unserviceable debris off the premises complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm of broken stone boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed.
M&L for Cement concrete 75mm thick, (1:4:8)Type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed
M&L for Heavy duty ceramic tiles 10-12mm thick (square/rectangular) area of each tile not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed in CM (1:4) 20mm thick complete all as specified and as directed.
Dismantling existing Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc complete all as specified and as directed.
S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in ridges, roof covering/cladding to wall, fixed with self tapping screws etc all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed.
Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing) etc and removing the unserviceable debris off the premises complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete and removing the unserviceable debris off the premises all as specified and as directed.
M&L Joint free Glazed coloured ceramic tiles in vertical surface of size 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including rendering/backing coat in CM (1:4) 10mm thick complete all as specified and directed. (Note: Colour of tile will be finalized by Engr-In-Charge)
S&F for Joint free non - skid Ceramic coloured tiles 7 to 8 mm thick square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed in CM (1:6), 15mm thick complete all as specified and as directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust, etc. including brushing neat cement slurry @ 3.0kg of cement per sqm complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and 15 cm average depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:3:6 typeC-2. (using 40mm graded stone aggregate) as in plinth protection, finishing the cement concrete surface even and smooth without using extra cement all as specified and as directed.
M&L Chequered cement concrete tiles (glossy finish) 20-30cm x 20-30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments in floors etc, laid over and including screed bed in CM (1:4) 20mm thick complete all as specified and as directed.
Removing excavated surplus soil to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for Providing precast cement concrete blocks 1:2:4 Type B1 (using 20 mm graded stone aggregates) exc 10cm in width using as in kerb stones or in simillar works set in CM 1:4 finished even and fair complete all as speicfied and as directed.
M&L for preparation of New cement/ concrete surfaces of any description over 10cm girth or width, not otherwise described and applying Two coats of synthetic enamel paint over a coat of primer (plaster coat) etc all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing the unserviceable debris off the premises complete all as specified and as directed. (Reinforcement cut as required to facilitate demolition)
S&F of 110 mm bore PVC (SWR) pipes single socketed, in any length type 'B' laid in trenches or floors complete all as specified and as directed.
M&L for Formwork Rough finished in soffits of suspended slabs such as roof slabs, floor slabs, landings, walls and similar flat works, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr -in- charge.
M&L Reinforced cement concrete (nominal mix) 1:2:4 Type B1 (using 20 mm graded stone aggregate) as in Slabs supported on walls, deck slabs, shelves etc complete all as specified and directed by Engr -in- charge.
M&L for precast reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man holes cover slabs, shelves etc including necessary form work , complete all as specified and as directed.
S&F Mild steel TMT bars 10mm dia and over, cut to lenth, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia etc all as specified and as directed.
S & FMild steel TMT bars 5mm dia and up to 10mm dia as in stirrups, cut to length, bent to shape requiried, including brancking, bending spirally hooping for columns, hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20 mm thick Screed bed in CM 1:6 complete all as specified and directed by Engr -in- charge.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr -in- charge.
Demolition of brick work or stone/boulders, PCC block masonry built in Cement Mortar or cement lime mortar including all quoins, arches, pillars etc excluding ashlar facings, dressed stone work and precast concrete articles and removing the unserviceable debris off the premises complete all as directed.
M&L for pre-cast cement concrete block masonry (1:3:6) Type C1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed.
M&L Plain cement concrete (1:2:4) type B1, (using 20 mm graded stone aggregate) as in cills, lintets upto 1.5m clear span, bands, kerbs, bed plates, coping and benching including necessary formwork, weathering, slightly rounded or chamfered angles & throating complete all as directed.
M&L for Rendering 15mm thick in CM (1:4)on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement etc all as specified.
S&F in repairs, sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste coupling; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm etc complete all as specified and as directed.
S&F in repairs 40mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 in spouts as in sunken floor or in simillar etc complete all as specified and as directed.
S&F in repairs 75mm dia PVC (SWR) floor/nahani trap plain with grating including jointing with solvent cement and jointing to waste pipe mounted with cement concrete (1:2:4) type B1 complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation etc or n. exc. 10sqm on plan and getting out in soft/loose Soil complete all as specified and as directed.
Returning, filling in trenches with approved soil obtained from excavation, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing Excavated surplus soil to a distance exceeding 250 M and n. exc 500 m and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
M&L Plain cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete etc., comeplete all as specified and directed.
S&F 15 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls, ceilings or laid in floors etc complete all as specified and as directed.
S&F 20 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls, ceilings or laid in floors etc complete all as specified and as directed.
S&F 20mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair of Bib taps, CP fancy type screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe etc complete all as specified and as directed
M&L for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) for concrete bed of 10cm thick, to drain pipes of 100 mm dia including forming cradles, complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) pipes type 'B' single socketed, in any length laid in trenches or floors complete all as specified and as directed.
S & F 110 mm dia bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F 75 mm bore PVC (SWR) pipes type 'B' single socketed, in any length fxed to walls or in floors, etc complete all as specified and as directed.
S & F 75 mm dia bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F 75 mm dia bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F in repairs of Waste coupling of 32 mm with long screwed shanks and fly-nuts complete all as specified and directed by Engr -in- charge.
S&F stainless steel gratings 100mm dia, hinge or openable type, fixed with solvent cement or other suitable chemicals complete all as specified.
Dismantling stone slab and tiles of any descriptions / position or any thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed.
M & L Machene cut and polished Kota stone slab flooring 20-25 thick laid over and incl cement mortor screed bed (1:4) 20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror finished, complete all as specified and directed.
Deepika Enterprises
S J REDDY
M/s D.Krishna Varma
M/s RAMA LAKSHMI CONSTRUCTIONS
M/s Amit Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .