Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HOUSE NO 18 1 DHOBIGHAT ROAD NEAR DC OFFICE WARD NO 12 SOLAN DISTT SOLAN H P 173212 | SOLAN | SOLAN | HIMACHAL PRADESH | 173212 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance DHALIWAL | TARN TARAN | PUNJAB | 143107 | Admitted-Finance |
Tender Value
₹13.1 L
EMD Value
₹26,250
Closing Date
7 Nov 2020, 11:00 amClosed
Er. Amit Dogra
XENJalShakti Division Nuprur
C/O 21 Nos. Tube-well in Nuprur Constituency C/O Tube- well Pucca Tiala-5th
2020_HPIPH_41904_1
NPRKNG04 dated07-11-2020
Open Tender
Civil Works
Item Rate
120 days
Nurpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹400
Yes
EE Nurpur
₹26,250
Yes
10 Nov 2020
24 Oct 2020
7 Nov 2020
24 Oct 2020
7 Nov 2020
24 Oct 2020
Amount
Supply of Submersible Pumping Set of Calama/KSB/Crompton/SU/Johnston /BS/Sabar make conforming to BIS-8034-1976 (Latest) suitable for clear water fitted with bronze Impellers or suitable alloys directly coupled to squirrell cage electric Induction Motor of same make as that of Pump conforming to BIS:9238-1979(Latest with uptodate ammendments) and totally water proof for Submersible duty,isolated from the pump by intermediate casing with double Mechanical seal in oil chamber,grease packed lubricated bearings and provided with stainless steel thrust bearing plate to withstand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take-up expansion of water with the heating of motor including water level guard,erection clamps,cable clips and depth gauge etc. The Pump shall be sui-table for operation on data given below:-
Location of site :-The site is located at a distance of 30 Kms.from Nurpur Road Railway Station.
The altitude of place in which :-Altitude of place is 500 Metres above Mean Sea Level the Motor is intended to work
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
Rated Voltage :-415 Vvolts (+/-) 10%
Characterstics of water :-(a).Temperature = 20°C (f) PH =_7 to 8____ (b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre (c). Hardness =__Mg/Litre(as CaCo3) (h). Others_____ (d).Alkalinity =__Mg/Litre(as CaCo3)
Depth of T/Well Assembly :- 21.34 Metres.B.G.L.
L.W.L.in P/ Well :- 421.96 Metres
Maximum draw down level :- 421.96 Metres
Centre line level of Pump :- 421.96 Metres
Discharge level of highest point :- 457.50 Metres
Nos.of Pumps required :-1 No.Pump.
Capacity :- 17.99 L.P.S.
Total head in Metres :- 49.41 Metres
Length of Rising Main :- 650.00 Metres
Dia of Rising Main :- 150 mm dia MSERW Pipe
No.of working hours per day : -20.00 Hours.
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
H.P.of Motor/Drive unit :-Required 25 H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. . BHP.with following margins/multiplying factor at duty point,whichever is higher. . a).Upto 2 H.P. =1.50 (d) 10 to 20 H.P. =1.20 . b).2 to 5 H.P. =1.40 (e) 20 to 100 H.P. =1.15 . c) 5 to 10 H.P. =1.30 (f) Above 100 H.P. =1.10
Test Run :-8 Hours continueously for 7 days.
Providing and fixing Cast iron double flanged sluice valve of Kirloskar/Kilburn/IVC./Fouress /Gled/BHEL/Leader make of size mm.and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm². confirming to BIS 780-1984 (The size and class of valve shall be specified by the tenderer)..
Providing and fixing of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make Cast iron double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size mm.dia and class PN 1.0 and shall be suitable for withstanding nominal seat pressure of 10.20 Kgs./cm² confirming to BIS 5312-1984 Part-II )(The size and class of valve shall be specified by the tenderer).
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make Cast Iron double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 150mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20 Kgs./Cm²).confirming to BIS 5312-1984
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable of size mm² conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost.
Suppply side mm Square (The size of cable shall be specified by the tenderer).
Providing and laying PVC.jointless flat water proof copper cable mm² as per BIS-694-1990(Latest with uptodate ammend-ments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost.
Motor side mm Square (The size of cable shall be specified by the tenderer).
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper strips of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
Supply and erection of floor/wall mounted power factor shunt capacitor conforming to BIS-2834-1986 latest with upto-date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to Induction Motor individually of required KVAR according to H.P.of Motor offered including Siemens/Gloster/ICC make from Busbar chamber to capacitor and also including LT/LK/Kilburn make ICTP.Switches conforming to BIS-4064-1978 or latest with HRC fuses(Range to be specified by the tenderer).
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments.
Lowering of column assembly of suitabie dia and making connection with Rising Main(150mm dia)G.I.pipe Conforming to IS-1239 or MSERW.Pipe 4.8mm tick conforming to BIS 1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971 (Table-5 )including tapers,flanges,rubber gaskets 3 mm thick as per BIS-2712-1978 ,nuts &bolts as per 1364-1983 as per .direction of Engineer-in-Charge or as per layout approved by the Engineer-in-Charge.The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xiii)
column pipe mm-dia (size to be specified by the tenderer).
Erection of all equipments from S.No. 1 to 4 and 6 including cost of tees, bends,tapers and any other fittings required
Excavation in foundation treanches(Pipe & Pits) up to all depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing or pumping out water,blasting soft /hard rock where blasting is prohibited in all lifts including trimming & dressing of sides leveling of beds to correct grade i/c shoring/strutting planking,timbering & dewatering wherever required stacking the usable & unusable material/soil separately & after laying,jointing & testing of pipes,returning the useable soil in trenches in 15cm layers including consolidating of such deposited layer by raming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surface to its original condition & including cost of diversion for traffic,night signals,fixing caution boards,crossing over trenches for access to houses,fencing etc.completein all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Providing, laying, jointing and testing of 150mm dia MSERW pipe(Zinc coated) plane ended pipe with circumferential butt welded joints by eclectric arc welding (welding thickness shall be equal to pipe wall thickness) conforming to IS:3589-2001 (latest with up to date amendments) of steel grade Fe-330 having 4.80mm wall thickness and capable of withstanding required test pressure in random length of 4 to 6 meters including manufacturing / fabrication of reducer, tapers, tees, all short pieces, bends of required degrees per site requirement made from parental tubes which shall included all operational such as cutting, welding, jointing, lowering and laying of pipe in excavated trenches to ensure required level complete in all respects to the entire satisfaction of Engineer-in-charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (Zinc coated both inside and outside) as per relevant IS standard including entire carriage of material flushing, cleaning and hydraulic testing. DP test of butt welding joints complete in all respect to the best satisfaction of Engineer-in-charge within all leads and lifts
R.Ds Dia of Pipe Wall Thickness Outer dia Weight of pipe per Rmt. Table
0 to 650 150mm 4.80mm 168.30mm 16.208 5
ROHIT VERMA
SG Engineers and Consultants
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .