| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.4 LAccepted-AOC AT KALINGA VIHAR VIA PATRAPADA DIST KHURDA ODISHA | KHORDHA | ODISHA | 751001 | L1 | Accepted-AOC Contract value is excluding GST | |
| 2 | L2₹1.0 Cr+₹8.5 L (8.81%)Rejected-Finance BYE PASS ROAD JEYPORE KORAPUT | KORAPUT | ODISHA | 763001 | L2 | Rejected-Finance Quoted amount excluding GST | |
| 3 | Rejected-Technical AT PO NAKEIPASI DANARA TALCHER ANGUL PIN 759103 | ANUGUL | ODISHA | 759103 | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
15 Apr 2025, 5:00 pmClosed
General Manager(Mech.),E andM
Office of General Manager(Mech.),E and M, OCC Ltd., Rasulgarh, Bhubaneswar.
Erection, commissioning and testing of last 04 Nos. of Spillway R.G of size 15.000 mtr. x 12.078 mtr 04 Nos. 130T capacity hoisting arrangements for radial gates in Bay No. 9,10,11 12 painting 2nd. stage concreting of Kanpur G.E.P, Keonjhar
2025_OCCL_111974_1
E-Procurement Notice No 59 /OCCL /2024-25 (on-line)
Open Tender
Mechanical Works
Item Rate
180 days
Basudevpur, Keonjhar
Please refer tender documents
3 documents required · 3 mandatory
₹11,800
₹1.1 L
Yes
15 Jul 2025
28 Mar 2025
16 Apr 2025
28 Mar 2025
15 Apr 2025
28 Mar 2025
28 Mar 2025 - 5 Apr 2025
Amount
RADIAL GATES-(Size 15.000 Mtr. x 12.078 Mtr.)
Erection, Commissioning & testing, of 04 (Four) Nos of Radial Gate including seal, guide roller, horizontal girder with bracing, end arms with bracing, trunnion hub assembly, pulley assembly, latch assembly etc. and as per drawings, scope of work & instruction of Engineer-in-Charge.
Erection Commissioning & testing of 04 (Four) Nos 130T rope drum hoist assembly including hoist bridge assembly , central drive assembly, gearbox assembly, floating shaft assembly, wire rope assembly , pulley & turn buckle assembly, position indicator assembly, hand drive assembly, latch assembly, covers for hoist as per drawings, scope of work & instruction of Engineer-in-Charge.
Erection & testing of Wall plates for 04 (Four) Nos of Radial Gate.
2nd. Stage concreting of Wall plates for 04 (Four) Nos of Radial Gate.
2nd. Stage concreting of 04(Four) sets hoist bridge
Painting of 04 (Four) sets of Radial Gate and its all components after surface preparation by blast cleaning process performed with sand as per requirements & class 'A' of IS 14177: 1994. After blast cleaning, the surface should be cleaned from loose dust & debris preferably by air blast with help of blower. Over the prepared surfaces, two coats of zinc rich primer (containing not less than 85% zinc rich on dry film) should be applied to give a dry film thickness of 70 ± 5 microns. First coat of primer should be applied within six hours of sand blasting. Fnishing coat should consist of 02 coats of solventless coal tar epoxy paints. These should be applied at an interval of 24 hours. Each coat should give minimum dry film thickness of 150 ± 5 microns. Total dry film thickness of all coats including primer coat should not be less than 350± 5 microns as per 14177: 1994.. The rate should include cost of sand, hire charge of compressor, painting equiments, labour, other machinery, scaffolding etc. required for painting as per scope of work & direction of Engineer-in-Charge.
Finish painting of 04 (Four) sets already sand blasted & primer painted Radial Gate and its all components (to be supplied by Occl.) with 02 coats of solventless coal tar epoxy paints. These should be applied at an interval of 24 hours. Each coat should give minimum dry film thickness of 150 ± 5 microns. Total dry film thickness of all coats including primer coat should not be less than 350 ± 5 microns as per 14177: 1994.. The rate should include cost of sand, hire charge of compressor, painting equiments, labour, other machinery, scaffolding etc. required for painting as per scope of work & direction of Engineer-in-Charge.
Painting of 04 (Four) sets 130 T rope drum Hoists including hoist bridge, pulley support girder, latch after surface preparation by blast cleaning process performed with sand as per requirements & class 'B' of IS 14177: 1994. After blast cleaning, the surface should be cleaned from loose dust & debris preferably by air blast with help of blower. Over the prepared surfaces, two coats of zinc phosphate primer should be applied to give a dry film thickness of 40 ± 5 microns per each coat. First coat of primer should be applied within six hours of sand blasting. Finishing coat should consist of 01 coat of alkyed based micaceous iron oxide paint at dry film thickness of 65 ± 5 followed by 02 coats of synthetic enamel paint confirming to IS 2932 : 1974 to give dry film thickness of 25 ± 5 microns per coat of synthetic enamel paint. Total dry film thickness of all coats including primer coat should not be less than 175± 5 microns. The rate should include cost of sand, hire charge of compressor, painting equiments, labour, other machinery, scaffolding etc. required for painting as per scope of work & direction of Engineer-in-Charge.
NEELAMADHAB ENGINEERING WORKS (BID ID -2884658)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .