Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | ₹13.4 L | L1 | Accepted-AOC L-1 AND RESONABLE |
| 2 | L2₹14.2 L+₹80,324 (6.01%)Rejected-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹14.2 L+₹80,324 (6.01%) | L2 | Rejected-AOC NOT L-1 |
| 3 | L3₹15.3 L+₹2.0 L (14.8%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | ₹15.3 L+₹2.0 L (14.8%) | L3 | Rejected-AOC NOT L-1 |
Tender Value
₹13.2 L
EMD Value
₹26,400
Closing Date
29 Apr 2021, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
PROVN OF MEDICAL GAS PIPELINE SYS AND ALLIED STRUCTURES FOR MH VADODARA UNDER GE (Army) VADODARA
2021_MES_434094_1
86957
Open Tender
Civil Works - Others
Item Rate
90 days
ARMY AREA BARODA
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BARODA
₹26,400
Yes
17 May 2021
2 Apr 2021
30 Apr 2021
2 Apr 2021
29 Apr 2021
17 Apr 2021
Amount
MEDICAL GAS PIPE LINE SYSTEM;-Supply, installation, Testing and Commissioning of the pipe distribution system Lloyds' certified medical grade copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN-13348:2016 or latest grade and mechanical properties in accordance with HTM2022/HTM02-01, copper fitting should be as per above norms EN-1254-1 1998 or revised and plastic saddles will have brass screws.Make: Mexflow/BDM (a) 15mm OD X 0.9mm thick
Gas Outlet Points/ Terminal Unit : Supply, installation, testing and commissioning of Gas outlet points for Qxygen 4 Bar, and Vaccum. Front loading type outlets. Out let should be specific so that secondary device cannot be attached.Flow rate exceeds the requirement of ISO 9170-1:2017.The terminal outlet should comply with ISO9170-1:2017 certification Make-Linde/Praxair/AKTIV (a) Oxygen outlet double lock with probe
b) Vaccum outlet double lock with probe
Medical Gas Alarm Panel : Supply, installation, testing and commissioning of Medical Gas Alarm Panel microprocessor controlled Alarm for Pneumatic and vacuum services having following feature, Digital/analog display of line presure for all the services with factory calibrated pressure sensors,color coded LED display of line presure status(High-caution-Normal-caution-Low), Audible alarm for high and low pressure condition, test and alarm acknowledge(mute)facility(Alarm acknowledge(mute) time span is programmable from 1 to 60 min). Programming facility of alarm limits from front panel(Password protected).Facility to connect to remote alarm box by potential free contacts provided in the alarm box. Imported high sensitive gas pressure sensors and USA/CE marked power supply.Nut and Nipples are to be provided for connection.Mounted on Powder coated MS Box, Low voltage internal operation for safety with input power supply of 230V,50Hz AC.High /Low indication with test facility.Make-Linde/Praxair/AKTIV (a)Medical gas alarm Panel - 2 gas service
LINE ISOLATION VALVES- These shall be of the ball valve type and shall be constructed of Nickel plated brass body,PTFE seat and brass chrome plated ball. Line valve installation should be carried out as per HTM2022/HTM02-01 standards. Make Audco/LEADER/ AKTIV/MATRIX (a) 15mm ball valve
Oxygen Manifold (2 X 02 cylinders) : Supply, Installation, Testing and Commissioning of 2x 02 cylinders Oxygen Manifold and should be suitable to withstand working pressure of 145KG/cm2 along with 10 Nos of high pressure copper annealed tail pipes with end brass adapter suitable for oxygen cylinder and manifold . 02 cylinder manifold bank as left side and 02 cylinder manifold bank as right side complete with 10 Nos of pig tail pipes and 10 Nos of non return valve Top frame should comprise of high pressure copper pipes of size 1/2" NB X15 swg with high pressure brass fittings made of high tensile brass and connections through non return valves; high pressure copper tail pipes, made of high pressure copper pipes of size 1/4" NB X15 swg. The design of middle and bottom frame should be provided to fit both round and flat bottom cylinders safely. The manifold must be tested (hydralically) at 3500 psig bar and necessary test certificates should accompany along with the supply. the manifold system should conform to IS 12827 standard should be upgradable to include more cylinder banks.only Halogenated Polymer materials are to be used in the Non Return valves supplied alongwith manifold.Make-Linde/Praxair/AKTIV
Oxygen Manifold (2 X 03 cylinders) : Supply, Installation, Testing and Commissioning of 2x 03 cylinders Oxygen Manifold and should be suitable to withstand working pressure of 145KG/cm2 along with 10 Nos of high pressure copper annealed tail pipes with end brass adapter suitable for oxygen cylinder and manifold . 03 cylinder manifold bank as left side and 02 cylinder manifold bank as right side complete with 10 Nos of pig tail pipes and 10 Nos of non return valve Top frame should comprise of high pressure copper pipes of size 1/2" NB X15 swg with high pressure brass fittings made of high tensile brass and connections through non return valves; high pressure copper tail pipes, made of high pressure copper pipes of size 1/4" NB X15 swg. The design of middle and bottom frame should be provided to fit both round and flat bottom cylinders safely. The manifold must be tested (hydralically) at 3500 psig bar and necessary test certificates should accompany along with the supply. the manifold system should conform to IS 12827 standard should be upgradable to include more cylinder banks.only Halogenated Polymer materials are to be used in the Non Return valves supplied alongwith manifold.Make-Linde/Praxair/AKTIV
Medical Vaccum Plant Package Supply installation, testing and commissioning Medical vacuum plant system shall ensure the minimum pipeline. Vacuum level of 450 mm Hg is maintained at the plant service connection point at the rated volumetric "free Air" flow rate with one pump stand by. The bacteria filtration system shall be duplexed such that each filter can be isolated for replacement of the filter cartrige. Duplex vaccum pumps consisting 02 Nos air cooled ,oil lubricated rotary vane/reciprocating vacuum pumps piston displacement not less than 34.60 CFM, operation at nominal inlet vacuum level between 578 mmHg and 728 mmHg, Pump coupled with TEFV electric motor 2 HP for each.Pump inlet shall include a wire mesh filter and integral non return valve to prevent oil suck back and pressure increases in the vacuum system. Each vacuum pump shall have an integral separator filter to ensure a virtually oil-free exhaust with Vacuum receiver with relevent certificate and have total volume of at least 100% of the plant output in 1 minute in term of free air aspired at normal working. vacuum receiver not less than 150 ltr shall be hot dip galvanised inside and out side. Bacteria Filters & contorl and instrumentation panel as recommendation of NFPA or HTM2022 standard and designed according to vacuum outlets Make - Ingersoll RandIndia or equivalent
Medical Vaccum Plant Package Supply installation, testing and commissioning Medical vacuum plant system shall ensure the minimum pipeline. Vacuum level of 450 mm Hg is maintained at the plant service connection point at the rated volumetric "free Air" flow rate with one pump stand by. The bacteria filtration system shall be duplexed such that each filter can be isolated for replacement of the filter cartrige. Duplex vaccum pumps consisting 02 Nos air cooled ,oil lubricated rotary vane/reciprocating vacuum pumps piston displacement not less than 59.65 CFM, operation at nominal inlet vacuum level between 578 mmHg and 728 mmHg, Pump coupled with TEFV electric motor 5 HP for each.Pump inlet shall include a wire mesh filter and integral non return valve to prevent oil suck back and pressure increases in the vacuum system. Each vacuum pump shall have an integral separator filter to ensure a virtually oil-free exhaust with Vacuum receiver with relevent certificate and have total volume of at least 100% of the plant output in 1 minute in term of free air aspired at normal working. vacuum receiver not less than 300 ltr shall be hot dip galvanised inside and out side. Bacteria Filters & contorl and instrumentation panel as recommendation of NFPA or HTM2022 standard and designed according to vacuum outlets Make - Ingersoll RandIndia or equivalent
Oxygen Flow Meter with Humidifier Bottle : Supply installation, testing and commissioning of oxygen flowmeter with humidifier bottle,control with in range of 0-15 LPM(Calibrated with in +/- 10%). Body is made of brass chrome plated materials. The flow tube and shroud component are made of clear ,impact resistant polycarbonate.filters of stainless steel wire mesh, humidifier bottle should be made of unbreakable polycarbonate material and autoclavable at 121degree Centigrade temperature.Make-Linde/Praxair/AKTIV
Ward Vaccum Unit : Supply installation, testing, and commissioning of Ward suction unit consist of a regulator with 0-760 mm gauge ,a 1000ml reusable collection jar, made of unbreakable poly carbonate material and fully autoclavable at 121 degree centigrade temp, wall bracket for mounting the Jar. The Vacuum regulator shall be infinitely adjustable and have vacuum guage which indicates suction supplied by the regulator safety trap shall be provided inside the Jar to safe guard the regulator from overflowingMake-Linde/Praxair/AKTIV
M&L for Oxygen regulator(Mox Regulator) OR 14between main mainfold and emergency manifold complete all as specified MakeLinde/Praxair/AKTIV
Medisystem Bed-Head Panle with Extruded Aloumium Sheed body ,Pre -tested W matt stain finish Epoxy Polyester Power coat in cloour of customs choice ,wfollowing configeration:- Room Panels ,w/1100mm lenth panel :-2 Nos ,16 A MCB isolation wired ,6 Nos 16/6Amp electrical Switch /Sockets(RAW) ,suction Bottel Holder,Provn for 2 Nos electricla isolated medical gas outlets ,Electric Wiring factory harnessed & tested.
Medisystem Bed-Head Panle with Extruded Aloumium Sheed body ,Pre -tested W matt stain finish Epoxy Polyester Power coat in cloour of customs choice ,wfollowing configeration:- Room Panels ,w/700mm lenth panel :-2 Nos ,10 A MCB isolation wired ,4 Nos 16/6Amp electrical Switch /Sockets(RAW) ,suction Bottel Holder,Provn for 2 Nos electricla isolated medical gas outlets ,Electric Wiring factory harnessed & tested.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for the shafts, well, cesspits, manholes, pier holes, etc n exc 10 Sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil.
Removing excavation material exe. 250m but n exc. 500m & deposited where directed at a level n exc. 1.5m above the starting point
M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as directed.
M & L for Hardcore of broken stone/boulder of gauge not exc 63mm deposited, spreaded & levelled in layers n exc 15cm thick including watering and ramming etc complete all as specified and directed.
M & L for 150mm thick cement concrete 1:4:8, type D-2, (using 40mm graded stone aggregate) as in sub base, etc. all as specified and directed.
M & L for cement concrete work in pavement / hard standing, (1:2:4) type B-1(20mm graded stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, thickness of concrete 15 cm or less all as specified and directed. Note :- 1.Top surface of concrete shall be finished with broomes as directed. 2. Brooming shall be measured and paid separately under ser item No 10 here in after.
M & L for finishing surface of concrete pavments, hard standing, by brooming all as directed.
Formoing contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound ''B''
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound 'B'
M & L for mild steel work confirming to Fe-290 Gde E-165 in angle iron posts & struts in fencing including cutting top to shape as directed, drilling holes, noteching for wire etc. and including flat iron filletes for securing wire mesh or fence etc. including all necessary bolting riviting etc complete.
M & L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') etc., complete.
M & L for preparation of new steel Surfaces of any description, over 10cm in width or girth, and applying two coats of synthatic enamel paint over a coat of red oxide primer.
M & L for Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. all as specified & as directed.
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws, in modular boxes fixed on wall ( with earth dolly) with Modular switch cover for fixing of switches, sockets and accessories etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site as given in Item NO. 1.01 TO 1.0 (NOTE: Modular Switch and socket, modular sunken boxes modular switch cover inner and outer to be measured and paid for separately:-
One 3 pin switch socket combination 6 amp on the independent board.
One 3 pin switch socket combination on same board with other switches.
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
S&F modular white cover plate with frame, 3 module.Make : Legrand/Anchor/Havells
S&F modular white cover plate with frame, 12 module.Make : Legrand/Anchor/Havells
S&F Surface mounted metal boxes for modular switch and sockets 3 Module
S&F Surface mounted metal boxes for modular switch and sockets 12/16 (2 row x 6) module
M&L modular switch 1 way 6 A, 1 module.Make : Legrand/Anchor/Havells
M&L modular switch 1 way 16 A, 1 module.Make : Legrand/Anchor/Havells
M&L modular socket, 6A-2/3 pin combined, 2 module.Make : Legrand/Anchor/Havells
M&L modular socket combination 16 Amps, 6 pin, 3 module.Make : Legrand/Anchor/Havells
S & F MCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V complete all as directed by Engr-incharge. Make: Legrand/Schneider/L&T/C&S
Supply and Fix only MCB TPN,63 Amps 4-Pole, 415 volts, breaking capacity10 KA complete all as specified
MCB , SP ( 6 upto 32 Amp) 240 Volt single pole, breaking capacity 10KA with "B" Charactristic complete all as specified
Supply and laying UPVC fire retardant corrosion free cable trunk in floors of size Width 100mm and height 50mm for medical equipment cables/electrical cables including all accessories complete all as specified and directed
Earthing complete with galvanized steel plate electrode 60 cm x 60 cm x 6 mm surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25 meter below ground level with top edge of the earth plate at a depth of not less than 1.50 meter below ground level connected to galvanized iron or steel earth wire, 4 mm dia (No. 8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron, earth wire protected by galvanized steel pipe 15 mm dia (Light grade) & connected to main switch or main control board all as shown in electrical plate No. 5 of SSR-1991 Part I & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers 20 mm dia pipe (Light grade) for watering, protection pipe, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-I, 40 mm thick RCC (1:2:4) type B-1 cover and CI frame etc. NOTES: - (i) The unit rate includes earthing wire and protection pipe up to 7.5 metre. (ii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe bends elbow shall be deemed included in the rates.
Returning filling in excavated approved soil including spreading, leveling, watering and well ramming in layers n.exc 25cm in soil completed all as specified and directed
M&L for sand cushoning to cable with river sand and punning to provide required cover for UG cables complete
M&L brick protection cover to electric cable with sub class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVCtape armouredwith galvanised steel wire or tape and overall PVC sheathed 25sq. mm 4 Core nominal cross section in service connections .
M&L for galvanized steel tubing light Grade of 40 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
City Light
Dagli Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .